IAdsSymbol Properties

The IAdsSymbol type exposes the following members.

Properties

 

Name

Description

IAdsSymbol Properties 1:

Attributes

Gets the Type Attributes.
(Inherited from IAttributedInstance)

IAdsSymbol Properties 2:

BitSize

Gets the size of the IDataType in bits.
(Inherited from IBitSize)

IAdsSymbol Properties 3:

ByteSize

Gets the (aligned) size of of the Type/Instance in Bytes
(Inherited from IBitSize)

IAdsSymbol Properties 4:

Category

Gets the Symbol/Datatype Category
(Inherited from ISymbol)

IAdsSymbol Properties 5:

Comment

Gets the comment of the IInstance
(Inherited from IInstance)

IAdsSymbol Properties 6:

ContextMask

Gets the ContextMask of the symbol, indicating the task the variable belongs to. If ContextMask is not zero use CyclicInContext or OnChangeInContext to add notifications.
(Inherited from IContextMaskProvider)

IAdsSymbol Properties 7:

DataType

Gets the IDataType of the IInstance.
(Inherited from IInstance)

IAdsSymbol Properties 8:

DataTypeId

DataType identifier of the Symbol AdsDataTypeId

IAdsSymbol Properties 9:

ImageBaseAddress

Gets the AmsAddress of the Process Image

IAdsSymbol Properties 10:

IndexGroup

Gets the index group of the Symbol
(Inherited from IProcessImageAddress)

IAdsSymbol Properties 11:

IndexOffset

Gets the index offset of the Symbol
(Inherited from IProcessImageAddress)

IAdsSymbol Properties 12:

InstanceName

Gets the name of the instance (without periods (.)
(Inherited from IInstance)

IAdsSymbol Properties 13:

InstancePath

Gets the relative / absolute access path to the instance (with periods (.))
(Inherited from IInstance)

IAdsSymbol Properties 14:

IsBitType

Gets a value indicating whether this instance is not basing on a full DataType but instead of some sort of bit mapping
(Inherited from IBitSize)

IAdsSymbol Properties 15:

IsByteAligned

Indicates that the Size of the Object is Byte aligned (BitSize % 8 == 0)
(Inherited from IBitSize)

IAdsSymbol Properties 16:

IsContainerType

Gets a value indicating whether this Symbol is acontainer type.
(Inherited from ISymbol)

IAdsSymbol Properties 17:

IsPersistent

Gets a value indicating whether this ISymbol is persistent.
(Inherited from ISymbol)

IAdsSymbol Properties 18:

IsPointer

Indicates that the IInstance represents a Pointer type (Pointer TO)
(Inherited from IInstance)

IAdsSymbol Properties 19:

IsPrimitiveType

Gets a value indicating whether this instance is a primitive type.
(Inherited from ISymbol)

IAdsSymbol Properties 20:

IsProperty

Gets a value indicating whether IInstance is a property.
(Inherited from IInstance)

IAdsSymbol Properties 21:

IsReadOnly

Indicates that this instance is read only.
(Inherited from ISymbol)

IAdsSymbol Properties 22:

IsRecursive

Gets a value indicating whether this instance is recursive.
(Inherited from ISymbol)

IAdsSymbol Properties 23:

IsReference

Indicates that the IInstance represents a Reference type (REFERENCE TO)
(Inherited from IInstance)

IAdsSymbol Properties 24:

IsStatic

Gets a value indicating whether this IInstance is static.
(Inherited from IInstance)

IAdsSymbol Properties 25:

IsVirtual

Gets a value indicating whether this instance is virtual.
(Inherited from IProcessImageAddress)

IAdsSymbol Properties 26:

Parent

Gets the parent Symbol
(Inherited from ISymbol)

IAdsSymbol Properties 27:

Size

Gets the size of the object in bytes or Bits dependant on IsBitType
(Inherited from IBitSize)

IAdsSymbol Properties 28:

SubSymbols

Gets the SubSymbols of the ISymbol
(Inherited from ISymbol)

IAdsSymbol Properties 29:

TypeName

Gets the name of the DataType that is used for this IInstance.
(Inherited from IInstance)

IAdsSymbol Properties 30:

ValueEncoding

Gets the value encoding.
(Inherited from IAttributedInstance)

See Also

Reference

IAdsSymbol Interface TwinCAT.Ads.TypeSystem Namespace