ArrayType Class

Represents an Array DataType

Inheritance Hierarchy

System.Object
  TwinCAT.Ads.TypeSystem.DataType
    TwinCAT.Ads.TypeSystem.ArrayType

Namespace: TwinCAT.Ads.TypeSystem
Assembly: TwinCAT.Ads (in TwinCAT.Ads.dll) Version: 7.0.0+e56d35ccc4675faac24789a4aab60071fc61d470

Syntax

C#

public class ArrayType : DataType, IArrayType, 
IDataType, IBitSize

The ArrayType type exposes the following members.

Properties

 

Name

Description

ArrayType Class 1:

Attributes

Gets the attributes of the IDataType
(Inherited from DataType)

ArrayType Class 2:

BitSize

Gets the size of the DataType in bits.
(Inherited from DataType)

ArrayType Class 3:

ByteSize

Gets the (aligned) size of of the Type/Instance in Bytes
(Inherited from DataType)

ArrayType Class 4:

Category

Gets the Data Type category
(Inherited from DataType)

ArrayType Class 5:

Comment

Gets the comment.
(Inherited from DataType)

ArrayType Class 6:

DimensionCount

Gets the dimension count.

ArrayType Class 7:

Dimensions

Gets the dimensions as read only collection.

ArrayType Class 8:

ElementCount

Gets the element count.

ArrayType Class 9:

ElementSize

Gets the byte-size of a single element of the array

ArrayType Class 10:

ElementType

Gets the type of the contained elements.

ArrayType Class 11:

ElementTypeName

Gets the name of the element type.

ArrayType Class 12:

FullName

Gets the full name of the IDataType (Namespace + Name)
(Inherited from DataType)

ArrayType Class 13:

Id

Gets the ID of the DataType
(Inherited from DataType)

ArrayType Class 14:

IsBitType

Gets a value indicating whether this IDataType is a bit mapping Type
(Inherited from DataType)

ArrayType Class 15:

IsByteAligned

Indicates that the Size of the Object is Byte aligned (BitSize % 8 == 0)
(Inherited from DataType)

ArrayType Class 16:

IsJagged

Gets a value indicating whether this instance is jagged.

ArrayType Class 17:

IsOversampled

Gets a value indicating whether this array instance describes an oversampling type.

ArrayType Class 18:

JaggedLevel

Gets the jagged level (Non-Jagged Array have level 1)

ArrayType Class 19:

ManagedType

Gets the corresponding .NET Type if attached.
(Overrides DataType.ManagedType)

ArrayType Class 20:

Name

Gets the name of the Data Type (without namespace)
(Inherited from DataType)

ArrayType Class 21:

Namespace

Gets the namespace string within the IDataType exists.
(Inherited from DataType)

ArrayType Class 22:

Size

Gets the Size of the DataType in Bytes or bits.
(Inherited from DataType)

ArrayType Class 23:

TypeGuid

Gets the Guid of the DataType (optional)
(Inherited from DataType)

Methods

 

Name

Description

ArrayType Class 24:

Equals

Determines whether the specified object is equal to the current object.
(Inherited from Object)

ArrayType Class 25:

Finalize

Allows an object to try to free resources and perform other cleanup operations before it is reclaimed by garbage collection.
(Inherited from Object)

ArrayType Class 26:

GetHashCode

Serves as the default hash function.
(Inherited from Object)

ArrayType Class 27:

GetType

Gets the Type of the current instance.
(Inherited from Object)

ArrayType Class 28:

MemberwiseClone

Creates a shallow copy of the current Object.
(Inherited from Object)

ArrayType Class 29:

SetDimensions

Sets the dimensions.

ArrayType Class 30:

SetElementType

Sets the type of the element.

ArrayType Class 31:

ToString

Returns a String that represents this instance.
(Inherited from DataType)

Extension Methods

 

Name

Description

HasExternalDataReferences

Indicates, that the Instance value includes process memory data, that cannot be read in one memory block.
(Defined by DataTypeExtension)

IsArrayOfPrimitives

Determines whether the dataType is an array of Primitives.
(Defined by DataTypeExtension)

IsArrayOfPrimitives

Determines whether the dataType is an array of Primitives.
(Defined by DataTypeExtension)

IsContainer

Gets a value indicating whether this IDataType is a container type
(Defined by DataTypeExtension)

IsContainer

Gets a value indicating whether this IDataType is a container type
(Defined by DataTypeExtension)

IsPointer

Gets a value indicating whether this IDataType is a pointer type
(Defined by DataTypeExtension)

IsPrimitive

Gets a value indicating whether this IDataType is primitive
(Defined by DataTypeExtension)

IsPrimitive

Gets a value indicating whether this IDataType is primitive
(Defined by DataTypeExtension)

IsReference

Gets a value indicating whether this IDataType is a reference type
(Defined by DataTypeExtension)

ResolvableAsPrimitive

Indicates, that this data type can be resolved as primitive or primmitive Array.
(Defined by DataTypeExtension)

ResolvableAsPrimitive

Indicates, that this data type can be resolved as primitive or primmitive Array.
(Defined by DataTypeExtension)

Resolve

Resolves the specified data type for AliasReference (Resolving the IAliasType/IReferenceType)
(Defined by DataTypeExtension)

Resolve

Resolves the specified strategy.
(Defined by DataTypeExtension)

See Also

Reference

TwinCAT.Ads.TypeSystem Namespace

Beckhoff Automation GmbH & Co. KG 2001-2026