ValueSymbolExtensions.WhenValueChanged(IAdsConnection, IEnumerable<ISymbol>) Method

Observable sequence of Values driven by ADS Notifications on the specified symbol.


Namespace: TwinCAT.Ads.Reactive
Assembly: TwinCAT.Ads.Reactive (in TwinCAT.Ads.Reactive.dll) Version: 7.0.0+e56d35ccc4675faac24789a4aab60071fc61d470

Syntax

C#

public static IObservable<Object> WhenValueChanged(
this IAdsConnection connection,
IEnumerable<ISymbol> symbols
)

Parameters

connection  IAdsConnection

The ADS connection / ADS Client

symbols  IEnumerable<ISymbol>

The symbols to observe.

Return Value

IObservable<Object>
IObservable<ValueChangedArgs>.

Usage Note

In Visual Basic and C#, you can call this method as an instance method on any object of type IAdsConnection. When you use instance method syntax to call this method, omit the first parameter. For more information, see Extension Methods (Visual Basic) or Extension Methods (C# Programming Guide).

Example

The same for more than one IValueSymbol.

Observe changing ADS Symbols (ADS Notifications)

// To Test the Observer run a project on the local PLC System (Port 851)
using (AdsClient client = new AdsClient())
{
    // Connect to target
    client.Connect(new AmsAddress(AmsNetId.Local, 851));

    // Create Symbol information
    var symbolLoader = SymbolLoaderFactory.Create(client, SymbolLoaderSettings.Default);
    IValueSymbol cycleCount = (IValueSymbol)symbolLoader.Symbols["TwinCAT_SystemInfoVarList._TaskInfo.CycleCount"]; // UShort Type
    IValueSymbol lastExecTime = (IValueSymbol)symbolLoader.Symbols["TwinCAT_SystemInfoVarList._TaskInfo.LastExecTime"]; // UInt Type

    SymbolCollection symbols = new SymbolCollection();
    symbols.Add(cycleCount);
    symbols.Add(lastExecTime);

    // Reactive Notification Handler
    var valueObserver = Observer.Create<object>(val =>
    {
    Console.WriteLine(string.Format("Instance: {0}, Value: {1}", cycleCount.InstancePath, val.ToString()));
    }
    );

    cycleCount.NotificationSettings = new NotificationSettings(AdsTransMode.OnChange,500,5000); // optional: Change NotificationSettings on Symbol

    // Turning ADS Notifications into sequences of Value Objects (Taking 20 Values)
    // and subscribe to them.
    IDisposable subscription = client.WhenValueChanged(symbols).Take(20).Subscribe(valueObserver);

    Console.ReadKey(); // Wait for Key press
    subscription.Dispose(); // Dispose the Subscription
}

See Also

Reference

ValueSymbolExtensions Class WhenValueChanged Overload TwinCAT.Ads.Reactive Namespace Observable