AdsClient.AddDeviceNotification(String, Int32, NotificationSettings, Object) Method
Connects a variable to the ADS client. The ADS client will be notified by the AdsNotification event.
Namespace: TwinCAT.Ads
Assembly: TwinCAT.Ads (in TwinCAT.Ads.dll) Version: 7.0.0+e56d35ccc4675faac24789a4aab60071fc61d470
Syntax
C#
public uint AddDeviceNotification(
string symbolPath,
int dataSize,
NotificationSettings settings,
Object? userData
)Parameters
|
symbolPath String |
Symbol / Instance path of the ADS variable. |
|
dataSize Int32 |
Maximum amount of data in bytes to receive with this ADS Notification. |
|
settings NotificationSettings |
The settings. |
|
userData Object |
This object can be used to store user specific data (tag data) |
Return Value
UInt32
The notification handle.
Implements
IAdsNotifications.AddDeviceNotification(String, Int32, NotificationSettings, Object)
Remarks
The
dataSize
Parameter defines the amount of bytes, that will be attached to the AdsNotification as value. Because notifications allocate TwinCAT system resources, a complementary call to DeleteDeviceNotification(UInt32) should always called when the notification is not used anymore.
Reference
AdsClient Class AddDeviceNotification Overload TwinCAT.Ads Namespace AdsNotification DeleteDeviceNotification(UInt32) {0} Overload {0} Overload {0} Overload