RpcStructInstance Properties

The RpcStructInstance type exposes the following members.

Properties

 

Name

Description

RpcStructInstance Properties 1:

AccessRights

Gets the access rights. (Inherited from Symbol.)

RpcStructInstance Properties 2:

Attributes

Gets the Type Attributes. (Inherited from Instance.)

RpcStructInstance Properties 3:

BitSize

Gets the size of this Instance in bits. (Inherited from Instance.)

RpcStructInstance Properties 4:

ByteSize

Gets the (aligned) size of of the Type/Instance in Bytes (Inherited from Instance.)

RpcStructInstance Properties 5:

Category

Gets the the DataTypeCategory of the Instance. (Inherited from Instance.)

RpcStructInstance Properties 6:

Comment

Gets the comment. (Inherited from Instance.)

RpcStructInstance Properties 7:

Connection

Gets the connection that produces values for this IValueSymbol (Inherited from Symbol.)

RpcStructInstance Properties 8:

ContextMask

Gets the context mask of this instance. (Inherited from Instance.)

RpcStructInstance Properties 9:

DataType

Gets the IDataType of the IInstance. (Inherited from Instance.)

RpcStructInstance Properties 10:

HasValue

Gets a value indicating whether this instance has a value. (Inherited from Instance.)

RpcStructInstance Properties 11:

ImageBaseAddress

Gets the AmsAddress of the Process Image (Inherited from Symbol.)

RpcStructInstance Properties 12:

IndexGroup

Gets the index group of the Symbol (Inherited from Symbol.)

RpcStructInstance Properties 13:

IndexOffset

Gets the index offset of the Symbol (Inherited from Symbol.)

RpcStructInstance Properties 14:

InstanceName

Gets the name of the instance (without periods (.) (Inherited from Instance.)

RpcStructInstance Properties 15:

InstancePath

Gets the relative / absolute access path to the instance (with periods (.)) (Inherited from Symbol.)

RpcStructInstance Properties 16:

IsBitType

Gets a value indicating whether this instance is not basing on a full DataType but instead of some sort of bit mapping (Inherited from Instance.)

RpcStructInstance Properties 17:

IsByteAligned

Indicates that the Size of the Object is Byte aligned (BitSize % 8 == 0) (Inherited from Instance.)

RpcStructInstance Properties 18:

IsDereferencedPointer

Gets or sets a value indicating whether an ancestor is a dereferenced Pointer (Inherited from Symbol.)

RpcStructInstance Properties 19:

IsDereferencedReference

Gets or sets a value indicating whether an ancestor is a dereferenced Reference (Inherited from Symbol.)

RpcStructInstance Properties 20:

IsPersistent

Indicates that this instance is persistent. (Inherited from Instance.)

RpcStructInstance Properties 21:

IsPointer

Gets a value indicating whether this instance is reference. (Inherited from Instance.)

RpcStructInstance Properties 22:

IsReadOnly

Indicates that this instance is read only. (Inherited from Instance.)

RpcStructInstance Properties 23:

IsRecursive

Gets a value indicating whether this instance is recursive. (Inherited from Symbol.)

RpcStructInstance Properties 24:

IsReference

Gets a value indicating whether this instance is reference. (Inherited from Instance.)

RpcStructInstance Properties 25:

IsStatic

Gets a value indicating whether this IInstance is static. (Inherited from Instance.)

RpcStructInstance Properties 26:

IsTcComInterfacePointer

Indicates that this instance is a TcComInterfacePointer. (Inherited from Instance.)

RpcStructInstance Properties 27:

IsTypeGuid

Indicates that this instance has set TypeGuid flag. (Inherited from Instance.)

RpcStructInstance Properties 28:

IsVirtual

Gets a value indicating whether this instance is virtual. (Inherited from Symbol.)

RpcStructInstance Properties 29:

Namespace

Gets the namespace name. (Inherited from Instance.)

RpcStructInstance Properties 30:

NotificationSettings

Gets or sets the notification settings. (Inherited from Symbol.)

RpcStructInstance Properties 31:

Parent

Gets the parent Symbol (Inherited from Symbol.)

RpcStructInstance Properties 32:

RpcMethods

Gets the Method descriptions for the IRpcCallableType

RpcStructInstance Properties 33:

Size

Gets the size of the IDataType in bytes or Bits dependant on IsBitType (Inherited from Instance.)

RpcStructInstance Properties 34:

SubSymbolCount

Gets the number of SubSymbols (Inherited from Symbol.)

RpcStructInstance Properties 35:

SubSymbols

Gets the SubSymbols of the ISymbol (Inherited from Symbol.)

RpcStructInstance Properties 36:

TypeName

Gets the name of the DataType that is used for this IInstance. (Inherited from Instance.)

RpcStructInstance Properties 37:

ValueEncoding

Gets the value encoding. (Inherited from Symbol.)

Reference

RpcStructInstance Class

TwinCAT.Ads.TypeSystem Namespace