Example: configuring and programming several spindles

3 spindles

Initialization in the axis parameter list

achs_typ     0x00004 Spindle
achs_mode    0x40000 Externally controlled spindle
antr_typ     0x00004 Simulation

Initialization in the channel parameter list

spdl_anzahl             3
main_spindle_ax_nr      6
main_spindle_name       S
spindel[0].bezeichnung  S1
spindel[0].log_achs_nr  6
spindel[1].bezeichnung  S2
spindel[1].log_achs_nr  11
...
spindel[2].bezeichnung  S3
spindel[2].log_achs_nr  30
...

The spindle "S1" with the logical axis number 6 is defined as the main spindle. It is addressed via the spindle name "S". The spindles with logical axis numbers 11 and 30 are programmed via their designations "S2" and "S3".

Example: configuring and programming several spindles 1:
Figure 1-7: Interfacing the three spindles to channel 1