PLC spindle

The PLC spindle is controlled by the PLC.

PLC spindle 1:Fig.5: PLC spindle

The spindle axis is configured and parameterized like an NC spindle. As no real drive needs to be supplied by the NC, the "simulation" or "virtual" drive type must be selected.

PLC spindles are commanded with speed or position commands from the CNC via the PLC interface (HLI). Control is realized by the PLC. The CNC merely receives an acknowledgement for M functions output to the spindle.

Parameters for the PLC spindle

P-AXIS-00015

Operating mode of the axis

P-AXIS-00016

Logical number of the axis

P-AXIS-00018

Type of the axis

P-AXIS-00020

Drive type of the axis

P-CHAN-00007

Designation of the spindle

 

P-CHAN-00036

Logical axis number of the spindle

 

P-CHAN-00051

Logical axis number of the main spindle

 

P-CHAN-00053

Designation of the main spindle

 

P-CHAN-00082

Number of spindles