Deleting the RAID system via BIOS
This method deletes the RAID system via the BIOS. The storage media can then be used separately again. You can delete a RAID system on industrial PCs with Intel Core I CPUs from the 9th generation via the BIOS.
Deleting the RAID system via UEFI BIOS
To delete a RAID system through the UEFI BIOS, follow the steps below:
- 1. Start the device and press & hold [DEL] while the device starts up.
- The BIOS appears.
- 2. Go to the tab Advanced using the [arrow keys] .
- 3. Use the [arrow keys] to go to Intel (R) Rapid Storage Technology and confirm with [Enter].
- The existing RAID systems are listed.
- 4. Use the [arrow keys] to go to the RAID system you want to delete and confirm with [Enter].
- 5. Use the [arrow keys] to go to the RAID Member Disk that you want to remove on the RAID system and confirm with [Enter].
- 6. Select Reset to non-RAID with [Enter]. Do NOT select delete, because in that case you will delete the data on the storage medium.
- 7. Confirm this question with Yes.
- 8. Repeat the last three steps for the second storage medium of the RAID system.

- The RAID system has been deleted. The storage media are listed as Non-RAID Physical Disks .