Environment

Environment

Operating temperature

-25 °C...+70 °C

The operating temperature is the ambient or surrounding temperature and is defined as the air temperature 2 cm below the device.

Storage temperature

-40 °C...+85 °C

For storage and transport

Power derating

3.2 W/°C
6 W/°C
15 W/1000 m or 5 K/1000 m
9 W/-5 kPa or 3 K/-5 kPa

Between +45 °C and +60 °C
Between +60 °C and +70 °C
For altitudes > 2000 m see Fig. below
For atmospheric pressures < 80 kPa, see Fig. below

The derating is not hardware-controlled. The customer must take care by himself to stay below the de-rated current limits in order not to overload the unit.

Humidity

5 to 95 % r.h.

According to IEC 60068-2-30

Atmospheric pressure

110-47 kPa

See Fig. below for details

Altitude

Up to 5000 m

See Fig. below for details

Pollution degree

2

According to IEC 62477-1, not conductive

Vibration sinusoidal

2-17.8 Hz: ±1.6 mm;
17.8-500 Hz: 2g
2 hours / axis

According to IEC 60068-2-6

Shock

30g 6 ms, 20g 11 ms
3 bumps / direction,
18 bumps in total

According to IEC 60068-2-27

Shock and vibration are tested in combination with DIN rails according to EN 60715 with a height of 15 mm and a thickness of 1.3 mm and standard orientation.

Audible noise

Some audible noise may be emitted from the power supply during no load, overload or short circuit.

Environment 1:Fig.14: Output current vs. ambient temp.; Output current vs. altitude