Environment

Environment

Operating temperature

-25 °C to + 70 °C

The operating temperature corresponds to the ambient or environmental temperature and is defined as the air temperature 2 cm below the device.

Storage temperature

-40 °C to + 70 °C

For storage and transport

Moisture

5 to 95 % r.h.

According to IEC 60068-2-30

Atmospheric pressure

110-54 kPa

 

Installation altitude

up to 5000 m

 

Degree of pollution

2

According to IEC 60664-1, non-conductive

Overvoltage category

N/A

 

Pulse dielectric strength

1.5 kV

Between input and chassis (according to IEC 60664-1 overvoltage category II)

Oscillation,
sinusoidal

2–17.8 Hz: ±1.6 mm;
17.8–500 Hz: 2 g
2 hours/axis

According to IEC 60068-2-6

Impact

30 g 6 ms, 20 g 11 ms
3 impacts/direction,
18 impacts in total

According to IEC 60068-2-27

The shock and vibration test takes place in combination with DIN rails according to EN 60715 with a height of 15 mm and a thickness of 1.3 mm and standard orientation.