EMC

The power supply is suitable without any restrictions for application in industrial environments as well as in residential, commercial and light industrial areas and small businesses. A detailed EMC report is available on request.

The device was tested according to EN 61000-6-1, EN 61000-6-2, EN 61000-6-3 and EN 61000-6-4.

EMC interference immunity

 

Strong transients

VDE 0160

Over the entire load range

750 V, 1.3 ms

EMC interference emission

According to the generic standards: EN 6100-6-3 and EN6100-6-4

Conducted interference emission, input lines

 

EN 55011, EN 55022, FCC Part 15, CISPR 11, CISPR 22

Class B

Conducted interference emission output lines

IEC/CISPR 16-1-2, IEC/CISPR 16-2-1

Limit values for the local DC power connection are met

Interfering radiation

EN 55011, EN 55022

Class B

Harmonic input current

EN 61000-3-2

Requirements for Class A devices met

Voltage fluctuations, flicker

EN 61000-3-3

Requirements met 1)

This device complies with FCC Part 15.

Operation is subject to the following two conditions:

  • This device must not cause adverse interference, and
  • This device must tolerate any interference it is subjected to, including interference that may cause undesired operation.

1) Tested with constant current loads, non-pulsating

Switching frequencies

PFC converter

40 kHz to 220 kHz

Dependent on input voltage and output load

Main converter

105 kHz

constant frequency

Auxiliary converter

35 kHz

constant frequency