Linear slope

P-AXIS-00011

Acceleration in Stage 1

Parameter

getriebe[i].lslope_profil.a_stufe_1

Description

This parameter is active during the acceleration and deceleration phases. It defines the acceleration in stage 1.

File type

UNS32

Data range

1 < P-AXIS-00011 < P-AXIS-00008 (a_max)

Dimension

Translatory: mm/s2

Rotatory: °/s2

Default

-

Remarks

-

P-AXIS-00012

Acceleration in Stage 2

Parameter

getriebe[i].lslope_profil.a_stufe_2

Description

This parameter is active during the acceleration and deceleration phases. It defines the acceleration in stage 2.

File type

UNS32

Data range

1 < P-AXIS-00012 < P-AXIS-00008 (a_max)

Dimension

Translatory: mm/s2

Rotatory: °/s2

Default

-

Remarks

-

P-AXIS-00221

Changeover speed

Parameter

getriebe[i].lslope_profil.vb_stufe_1_2

Description

This parameter defines the speed of changeover between Stages 1 and 2 during the acceleration and deceleration phases.

File type

UNS32

Data range

1 < P-AXIS-00221 < P-AXIS-00212 (vb_max)

Dimension

Translatory: μm/s

Rotatory: 0.001°/s

Default

-

Remarks