Example 2b: Programming an axis-specific M function in DIN syntax
Compatibility mode
After the introduction of axis-specific M and H functions, a compatibility mode became necessary to make it possible to use existing CNC programs for axis-specific output as well without changing the syntax.
Via the channel parameters
P-CHAN-00039 (m_default_outp_ax_name[MNr]) or
P-CHAN-00025 (h_default_outp_ax_name[HNr])
axis-specific output of an M or H function can be defined as the default. A channel-specific output then no longer takes place.
P-CHAN-00039 | Designation of the axis to which the M function with the number MNr is output |
P-CHAN-00025 | Designation of the axis to which the H function with the number HNr is output |
Initialization in the channel parameter list
m_synch[25] 0x0002
m_default_outp_ax_name[25] X
Programming example