Axis parameters
P-AXIS-00137 | Relative negative offset limit at manual mode | |
Parameter | handbetrieb.offsetgrenze_neg | |
Description | Position of the negative offset limit at manual mode
| |
Data type | SGN32 | |
Data range | MIN(SGN32) ≤ P-AXIS-00137 ≤ 0 P-AXIS-00137 and P-AXIS-00138 may not be 0 at the same time. | |
Dimension | translatory: 0,1µm | rotatory: 0,0001° |
Default | 0 | |
Remarks |
| |
P-AXIS-00138 | Relative positive offset limit at manual mode | |
Parameter | handbetrieb.offsetgrenze_pos | |
Description | Position of the positive offset limit at manual mode
| |
Data type | SGN32 | |
Data range | 0 ≤ P-AXIS-00138 ≤ MAX(SGN32) P-AXIS-00138 and P-AXIS-00137 may not be 0 at the same time. | |
Dimension | translatory: 0,1µm | rotatory: 0,0001° |
Default | 0 | |
Remarks |
| |