Introduction
Under consideration of the amount and direction with the manual mode offset limits the sum of the additional set point values, contributed from the hand control elements, is observed during running interpolation.
Effectiveness
Offset limitation is possible with exclusive manual mode (G200) or manual mode with parallel interpolation (G201). Für folgende Achstypen können Manual mode offset limits can be parametrized for the following axis types:
- Linear axes
- Rotatory axes
- Spindles
Parametrization
The limits for the manual mode offset (P-AXIS-00137/P-AXIS-00138) can be parametrized for each axis in the axis parameters list [AXIS].
Instruction
In NC program the manual mode offset limits can be instructed with the NC command #SET OFFSET..
![]() | The limitation of moving range by offset limits is also possible for modulo axes. |