Documentation issue status

Version

Comment

2.3.0

  • Approvals and markings updated

2.2.0

  • Chapter KL6201, KL6211 – Introduction updated
  • Chapter Technical data updated
  • Chapter IECEx - Special conditions added

2.1.0

  • Technical data updated
  • Ex markings added to technical data
  • Chapter KS2000 Configuration Software updated
  • Chapter AS-i installation updated
  • Chapter AS-i parameters - overview updated
  • Chapter Instructions for ESD protection added
  • Chapter Disposal added
  • New title page

2.0.0

  • Migration

1.5.0

  • Chapter on Mounting rail installation updated
  • Notes about Firmware Version of the Bus Couplers updated
  • Description of the AS-i string parameters added (AS-i string parameters are supported from firmware version BA)
  • Description of the AS-i command interface updated
  • Description of the AS-i settings via KS2000 updated
  • Mounting instructions updated

1.4

  • Description of the KL6211 AS-i master terminal with power contacts added
  • Description of the KL9520 AS-i potential feed terminal with filter added
  • Mounting instructions for AS-i master terminals added
  • Minor routine corrections (typing errors, spelling, etc.)

1.3

  • Description of the acknowledgement to the AS-i command interface (AS-i parameter 0x100) extended
  • Description of the process image updated and 6-byte process image added
  • Description of the KL6201 operation under PROFIBUS updated
  • Description of the KL6201 operation under CANopen updated
  • Notes about Firmware Version of the Bus Couplers updated

1.2

  • up to 62 AS-i slaves are now supported directly in the process image
  • analog AS-i slaves are supported
  • Description of KL6201 parameterization via KS2000 software added
  • Description of the AS-i parameters revised
  • Description of KL6201 operation under PROFIBUS updated
  • Description of KL6201 operation under CANopen updated
  • Description of the KL9528 AS-i power supply terminal added

1.1

  • up to 62 AS-i slaves are supported (32 directly in the process image, a further 32 via parameter access)
  • ID code 1 and 2 are now read during start-up
  • during short-circuiting of the SET inputs, ID codes 1 and 2 are also saved

1.0

  • Complete revision
  • Description of KL6201 operation under CANopen added

0.9

  • First preliminary version: Description of the KL6201 operation under PROFIBUS

Firmware and hardware versions

Documentation
version

KL6201 / KS6201

KL6211 / KS6211

Firmware

Hardware

Firmware

Hardware

2.3.0

D6

0K

D6

0K

2.2.0

D6

0K

D6

0K

2.1.0

D6

0K

D6

0K

2.0.0

D6

0J

D6

0J

1.5.0

BA

0D

BA

0D

1.4

B9

09

B9

09

1.3

B7

09

-

-

1.2

B4

09

-

-

1.1

B1-FE

05

-

-

1.0

B0

04

-

-

The firmware and hardware versions (delivery state) can be taken from the serial number printed on the side of the terminal.

Syntax of the serial number

Structure of the serial number: WW YY FF HH

WW - week of production (calendar week)
YY - year of production
FF - firmware version
HH - hardware version

Example with serial number 12 06 B9 09:

12 - week of production 12
06 - year of production 2006
B9 - Firmware version B9
09 - hardware version 09