Data exchange, function
Communication with the servo drive takes place via the process data (A0-A5, E0-E5). With
- A0/E0 is the control/status byte for the operating data communication and
- A3/E3 is the control/status byte for the parameter and server status communication with the device.
Operating data status byte E0
The operating data status byte issues potential servo drive error messages in process data exchange.
MSB
REG=0 | ERROR | ALARM | KOM_ERR | CRC_ERR |
|
|
|
Bit | Description |
|---|---|
ERROR | This is set when ALARM or KOM_ERR is set. |
ALARM | The alarm bit of the servo drive is displayed here. |
KOM_ERR | There has been a communication problem. No valid data is exchanged.
|
CRC_ERR | Faulty telegrams occur during data transmission (possibly EMC issue). |
Parameter control byte A3 when the servo control is set (bit 7 = 0)
Various actions are performed in the servo drive with this control byte.
MSB
REG=0 |
| RD_PARH | RD_PARL | RS_ANS | RF | /NSTOP | /PSTOP |
Bit | Description |
|---|---|
REG | This bit switches between servo parameter and servo control/status communication. |
RD_PARH | Read parameter High Word (parameter address in A4) |
RD_PARL | Read parameter Low Word (parameter address in A4) |
RS_ANS | Reset of communication monitoring or lag error. |
RF | Controller enable. The output stage is enabled and the brake (if available) is enabled at the same time. |
/NSTOP (active low) | Negative set values are set to zero. |
/PSTOP (active low) | Positive set values are set to zero. |
Parameter status byte E3 during acquisition of the servo status
Once enabled, the servo status word is continuously read and updated by the servo.
MSB
REG=0 | KOM_ERR | RD_PARH_Q | RD_PARL_Q | SERV_ERR | RF_Q | /NSTOP_Q | /PSTOP_Q |
Bit | Description |
|---|---|
REG | 0: The channel consisting of A3, A4, A5, E3, E4, E5 is in the operation mode with which the servo control/status is operated. |
KOM_ERR | An error has occurred during data transfer. |
RD_PARH_Q | E4, E5 contains the high word of the requested parameter value. |
RD_PARL_Q | E4, E5 contains the low word of the requested parameter value. |
SERV_ERR | The power section of the servo reports an error. |
RF_Q | The output stage and any existing brake are enabled. |
/NSTOP_Q (active low) | 1: Negative set values are possible. |
/PSTOP (active low) | 1: Positive set values are possible. |
Parameter control byte A3 in parameter operation mode (bit 7 = 1)
The parameter data is written to a buffer with the parameter address and transferred to the servo on request. This request can be made with the last buffer entry. The data frame is formed by the terminal, and the checksum is checked and evaluated. The parameter data form a maximum of one double word, but shorter parameter data can also be sent.
MSB
REG=1 |
| RD_PARH | RD_PARL |
| PUT_HW | PUT_LW | TRS_BUF |
Bit | Description |
|---|---|
REG | This bit switches between servo parameter and servo control/status communication. |
RD_PARH | Read parameter High Word (parameter address in A4) |
RD_PARL | Read parameter Low Word (parameter address in A4) |
PUT_HW | Write high word of the parameter to the buffer (A4, A5 parameter High Word). |
PUT_LW | Write low word of the parameter to the buffer (A4, A5 parameter Hight Word). |
TRS_BUF | Write data from the buffer to the parameter address set by A4. |
Parameter status byte E3 in Parameter operation mode
During parameter communication (REG = 1) with the servo, various acknowledgements are output in the status byte.
MSB
REG=1 | KOM_ERR | RD_PARH_Q | RD_PARL_Q | SERV_ERR | PUT_HW_Q | PUT_LW_Q | TRS_BUF_Q |
Bit | Description |
|---|---|
REG | 1: The channel consisting of A3, A4, A5, E3, E4, E5 is in the operation mode with which the parameter communication takes place. |