KL2531 - General connection examples
WARNINGRisk of injury through electric shock and damage to the device!
Bring the Bus Terminals system into a safe, de-energized state before starting mounting, disassembly or wiring of the Bus Terminals.
Note
Connect the motor strands correctly!
- one motor strand to clamping points A1 and A2,
- the other motor strand to clamping points B1 and B2.
Connection types
The KL2531 Stepper Motor terminal has bipolar output stages and can control bipolar and unipolar motors.
Bipolar motors
Bipolar control (serial) of a bipolar motor | Bipolar control (parallel) of a bipolar motor |

![]() | Documentation for stepper motors from Beckhoff These two examples show the connection of the bipolar Beckhoff motors AS1010, AS1020 or AS1030. |
Unipolar motors
Bipolar control of a unipolar motor |

Only one half of each winding is controlled.