Discrete Output Point Object
The IPxxxx provides Discrete Output Point Objects to access the discrete output channels data of the IPxxxx. For each discrete output point exits one instance of the Discrete Output Point Object Class.
For a detailed description of the Discrete Output Point Object see DeviceNet Specification Volume 2.
Class Code: 9 (09hex)
Class Attributes
Attribute ID | Access Rule | Name | Data Type | Description | Semantics of Value |
|---|---|---|---|---|---|
1 | get | Revision | UINT | Revision of implementation | 1 |
2 | get | Max. Instance | UINT | Max. number of instances |
|
Instance Attributes
Attribute ID | Access Rule | Name | Data Type | Description | Semantics of Value |
|---|---|---|---|---|---|
3 (03hex) | Get/Set | Value | BOOL | Output Point Value | 0: OFF |
4 (04hex) | Get | Status | BOOL | Output Point Status | 0: OK |
5 (01hex) | Get | Fault Action | BOOL | Action taken on Outputs value in Recoverable Fault State | see semantics |
7 (01hex) | Get | Idle Action | BOOL | Action taken on Outputs value in Recoverable Fault State | see semantics |