Keyboard filter

The keyboard filter is a possibility to protect the system from undesirable access. For example, a shortcut that leads to the closing of an application can be blocked. Only keyboard inputs required for the operation of the application are enabled. In addition, shortcuts can be specified that disable the keyboard filter. The option that disables the filter for the administrator is also helpful.

Keyboard filters offer a further option to limit a user in his dealing with the operating system and thus to minimize attack possibilities.

Typically, a "kiosk mode" is configured in which, for example, a successfully logged-in user can only start an HMI application. The user has no further possibility to start other programs or to send commands to the IPC, such as shutdown, for example.

Windows 11 provides a service for this purpose. Here, we describe how this is activated and how it can be configured.

First turn on the built-in Windows 11 feature to use the service. To do this, open the dialog Turn Windows features on or off and select the feature Keyboard Filter under the menu item Device Lockdown. Then restart the PC.

Keyboard filter 1:
1. Start the Microsoft Keyboard Filter service. Keyboard filter 2:
2. Set the startup type to automatic:
Keyboard filter 3:
3. Open the Registry Editor
Keyboard filter 4:
4. Navigate to KeyboardFilter: HKEY_LOCAL_MACHINE>SOFTWARE>Microsoft>Windows Embedded
Keyboard filter 5:
5. Both values and commonly used shortcuts are listed in the tables below.
The keyboard filter is now activated.

The following values stand for the individual shortcuts:

Value

Description

"Allowed"

Allow shortcut

"Blocked"

Block shortcut

DisableKeyboardFilterForAdministrator to "1"

Keyboard filter is disabled for administrators

BreakoutKeyScanCode to „01“

Scancode for ESC as Breakout

The following shortcuts are usually blocked:

Value

Description

CTRL-SHIFT-ESC

Open task manager

CTRL-ALT-DEL

Open menu with the following options:

Lock system

Open task manager

Change password

Shutdown system

Switch user

Further information can be found in the Microsoft documentation: https://docs.microsoft.com/en-us/windows-hardware/customize/enterprise/keyboardfilter