Documentation issue status

Version

Comment

1.9

  • Update to the chapter “Basics of sensor technology”
    • Subchapter “Basics of thermocouple technology” / “Overview of implemented TC transformations” added
    • Subchapter “Basics of strain gauge technology” / “Common-mode behavior in unbalanced full bridges” added

1.8

  • Update to the subchapters “Basics of sensor technology” and “Basics of RTD technology”
    • “Overview of common resistance sensors”
    • “Overview of implemented RTD transformations”
  • Addition of subchapters in the chapter “Notes on analog data values”
    • “Measurement of differential signals with high common-mode offset”
    • “Bandwidth, sampling rate and impedance of the measurement inputs”
    • “Influence of the mains frequency 50/60 Hz”

1.7

  • Update to the subchapters “Basics of sensor technology”, “Basics of RTD technology”, and “Overview of implemented RTD transformations” (update of NTC-RTD values; addition of coefficients for the Steinhart-Hart equation)
  • Updates in the subchapter “Notes on analog data values” / “Notes on analog specifications”
    • Subchapter “Ground reference: single-ended/differential typification” (explanation/differential)
    • Subchapter “Clarification of terms: GND/Ground”

1.6

  • Additions to the chapter “Product overview measurement technology” with subchapter “Shunt measurement”
  • Addition to the chapter “Notes on analog data values”
    • Subchapter “Shunt measurement” added
  • Update/addition in the subchapter “Notes on analog specifications” / “Notes on analog data values”
    • Subchapter “Impedance data” added
    • Subchapter “Temporal aspects of analog/digital or digital/analog conversion” updated
  • Updates in the chapter “Notes on analog data values”, subchapter “Analog information – shield and earth”
    • Section “FE/shielding, basic measures and information”
    • Section “Practice-oriented diagnostic methods for system examination”

1.5

  • Update in chapter “Notes on analog data values”, subchapter “Notes on analog specifications” / “Dielectric strength”
  • Addition to the chapter “Notes on analog data values” with subchapter “Repeatability”

1.4

  • Subchapter “Power supply” added to chapter “Product overview measurement technology strain gage, TC, RTD” (supplemented to “Product overview measurement technology strain gauge, TC, RTD, power supply”)
  • Subchapters “RTD/resistance measurement” and “Measuring bridges, strain gauges” updated in chapter “Product overview measurement technology strain gauges, TC, RTD, power supply”
  • Subchapter “Operation of inductive/capacitive loads on analog outputs” added to chapter “Notes on analog data values”

1.3

  • Updates in the chapter “Product overview measurement technology strain gauge, TC, RTD”:
    • Subchapter “Thermocouple (TC)”
    • Subchapter “RTD/resistance measurement”
  • Update in chapter “Basic considerations on analog technology”, subchapter “What else needs to be considered…”
  • Subchapters “Explanations on galvanically (un)isolated channels” and “On the mutual influence of non-isolated differential channels” in the chapter “Notes on analog data values” combined as a new subchapter “Galvanically (un)isolated channels” (title of the subchapter shortened to “Explanations”)
  • Subchapter “Wiring of differential current inputs” added to chapter “Notes on analog data values” / “Galvanically (un)isolated channels”
  • Update in chapter “Notes on analog data values”, subchapter “Galvanically (un)isolated channels” / “On the mutual influence of non-isolated differential channels”
  • Subchapter “Safety instructions” (foreword) updated

1.2

  • Chapter “Product overview: Measurement technology strain gauge, TC, RTD” updated
  • Chapter “Basics of sensor technology”, subchapter “Basics of strain gauge technology”, section “Measuring body and natural frequency” updated
  • Changes in the chapter “Notes on analog data values”
    • Subchapter “Signal quality when outputting signals with digital analog outputs – distortion factor” added
    • Subchapter “Readjusting the specification” updated
  • Chapter “What else needs to be considered…” moved to the chapter “Basic considerations on analog technology”

1.1

  • Chapter “Basic considerations on analog technology” updated
  • Refer to the chapter “Analog information – shield and earth” updated

1.0

  • First publication