Assembly Objects
The Assembly Object binds attributes of multiple objects, which allows data to or from each object to be sent or received over a single connection (IO or Explicit). Assembly objects are used to bind input data and output data.
Class Code: 4 (04hex)
Class Attributes
Attribute ID | Access rule | Name | Data type | Description | Semantics of Value |
---|---|---|---|---|---|
1 | Get | Revision | UINT | Revision of implementation | 2 |
Instance Attributes
Attribute ID | Access rule | Name | Data type | Description | Semantics of Value |
---|---|---|---|---|---|
3 (03hex) | Get/set | Value | Array of Byte | Input or Output Data of the ILxxxx-B520. |
|
Common Services
Service Code | Service Name | Description |
---|---|---|
14 (0Ehex) | Get_Attribute_Single | Returns the contents of the specified attribute |
16 (10hex) | Set_Attribute_Single | Modifies an attribute Value |
IO Assembly Instances
Number | Type | Name |
---|---|---|
101 | Output | Analog and Digital Outputs |
102 | Output | Digital Outputs |
103 | Output | Analog Outputs |
111 | Input | Analog and Digital Inputs and Status Byte |
112 | Input | Digital Inputs and Status Byte |
113 | Input | Analog Inputs and Status Byte |