FM33xx-B110 - 12 and 32 channel analog thermocouple input plug (TC-Plug)

Power cables

 

Ordering data

 
Order designation
Power cable
Screw-in connector
Contacts
Cross-section
Length
ZK2020-3200-0020
Straight socket, open end
M8
4-pin
0.34 mm2
2.00 m
ZK2020-3200-0050
5.00 m
ZK2020-3200-0100
10.00 m
ZK2020-3400-0020
Angled socket, open end
2.00 m
ZK2020-3400-0050
5.00 m
ZK2020-3400-0100
10.00 m
ZK2020-3132-0001
Straight socket, straight socket
0.15 m
ZK2020-3132-0005
0.50 m
ZK2020-3132-0010
1.00 m
ZK2020-3132-0020
2.00 m
ZK2020-3132-0050
5.00 m
ZK2020-3334-0001
Angled socket, angled socket
0.15 m
ZK2020-3334-0005
0.50 m
ZK2020-3334-0010
1.00 m
ZK2020-3334-0020
2.00 m
ZK2020-3334-0050
5.00 m

Further available power cables may be found in the Beckhoff catalog or on our internet pages (http://www.beckhoff.com).

 
 

Technical data

 
Technical data
Rated voltage according to IEC61076-2-101
30 VDC
Contamination level according to IEC 60 664-1
3/2
Insulation resistance IEC 60 512-2
>109Ω
Current carrying capacity according to IEC 60512-3
4 A
Volume resistance according to IEC 60512-2
< 5 mΩ
Protection class according to IEC 60529
IP65/66/67, when screwed together
Ambient temperature
-30°C to +80°C