Bus Terminals
Project planning and installation
Product | Product description |
---|---|
Notes on the use of the Beckhoff terminal systems in hazardous areas according to ATEX and IECEx | |
Notes on I/O components with analog in and outputs | |
Connection diagrams and Ex markings (according to cFMus) |
Digital input terminals
Product | Product description |
---|---|
Digital input terminals 24 VDC | |
up/down counter 24 VDC, 100 kHz | |
Digital input terminals | |
eight channel input + eight channel output terminal (high density, 24 V) |
Digital output terminals
Product | Product description |
---|---|
eight channel input + eight channel output terminal (high density, 24 V) | |
digital output terminals | |
dual channel output terminal, 24 VDC, 2 x 4 A/1 x 8 A | |
dual channel pulse width output terminal 24VDC, positive switching | |
single channel pulse train output terminal, RS422 | |
single channel stepper motor terminal (1.5 A) | |
dual channel output stage terminal for DC motors | |
dual channel pulse with current terminal (1 A) | |
dual channel power stage terminal for DC motors (1 A) | |
KL2602-0000 | two-channel Relay output terminal, with power contacts |
Watchdog terminal | |
Solid state terminals | |
Dimmer terminal (300 VA) | |
four channel digital output terminal with MOSFET transistors | |
single channel speed controller terminal for AC motors | |
eight channel digital output (high density, 30 VAC/DC) | |
eight channel digital output (24 VDC, 0.5 A) | |
sixteen channel digital output (24 VDC, 0.5 A) | |
sixteen channel digital output (24 VDC, 0.5 A, ribbon cable connection) | |
sixteen channel digital output (24 VDC, 0.5 A, switching to negative potential) |
Analog input terminals
Product | Product description |
---|---|
single channel analog input terminal, differential input (-10 V to +10 V) | |
single channel analog input terminal, differential input (0 to 20 mA) | |
single channel analog input terminal, Single ended input (0 to 20 mA) | |
single channel analog input terminal, Single ended input (0 V to 10 V) | |
dual channel analog input terminal, differential input (-10 V to +10 V) | |
dual channel accurate analog input terminal, differential input (-10 V to +10 V) | |
single channel input terminals for PT100 (RTD) | |
four-channel HD input terminal for 3-wire connection of resistance sensors | |
dual channel accurate input terminals for PT100 (RTD) | |
four-channel analog input terminal for PT1000, Ni1000 | |
eight channel input terminal for PT1000, Ni1000 (RTD), 2-wire technique | |
single channel thermocouple input terminals with open-circuit recognition | |
single channel terminal for resistance bridges | |
single channel accurate terminal for resistance bridges | |
single channel oscilloscope terminal | |
Power measurement terminal (1 A) | |
four channel analog input terminal (-10 V to +10 V) | |
four channel analog input terminal (0 to 20 mA) | |
four channel analog input terminal (4 to 20 mA) | |
four channel analog input terminal (0 to +10 V) | |
digital multimeter terminals |
Analog output terminals
Product | Product description |
---|---|
single channel analog output terminal, (0 V to 10 V) | |
single channel analog output terminal, (0 to 20 mA) | |
single channel analog output terminal, (-10 V to +10 V) | |
dual channel analog output terminal (0 to 20 mA), 16 bit | |
dual channel analog output terminal, (-10 V to +10 V) 16 bit | |
four channel analog output terminal (0 to +10 V) | |
four channel analog output terminal (0 to 20 mA) | |
four channel analog output terminal (4 to 20 mA) | |
four channel analog output terminal (-10 V to +10 V) | |
four channel analog terminal with 2 out and 2 inputs (-10 V to +10 V) |
Interface terminals for incremental encoder
Product | Product description |
---|---|
SSI Encoder interface | |
bidirectional SSI encoder interface | |
Incremental encoder interface | |
Incremental encoder interface | |
Incremental encoder interface with programmable Outputs | |
single channel interface terminal for incremental encoder | |
dual channel interface terminal for incremental encoder |
Communication terminals (for sub bus systems etc.)
Product | Product description |
---|---|
Serial Interface RS232C | |
Serial Interface TTY | |
Serial Interface RS485 (RS422) | |
Serial interface terminal for EnOcean Radio Technology | |
Serial Interface Terminal RS232 | |
Data exchange terminal with serial interface | |
Master terminal for AS-interface | |
Master terminal for IO-Link | |
EIB bus terminal | |
EnOcean master terminal | |
Master terminal for DALI/DSI (with integrated DALI power supply) | |
DALI-2 Multimaster terminal with integrated power supply | |
Master terminal for MP-Bus | |
Master terminal for M-Bus | |
Master terminal for SMI Bus (LoVo) |
Terminals for special functions
Product | Product description |
---|---|
Power terminal | |
Manual operating modules: placeholder module |
System terminals
Product | Product description |
|
---|---|---|
KL9020 | K-Bus Extension |
|
Diode array bus terminals | ||
Adapter terminal for manual operating modules |
| |
Potential feed terminal for AS-interface |
| |
KL9540 | Surge filter terminals |
|
Buffer capacitor terminal |
|
Furthermore documentation for Beckhoff Fieldbus Components can be found on our homepage (https://www.beckhoff.com).