FC750x - PCI Cards for SERCOS

Technical Data

 
FC7501
FC7502
Fieldbus
SERCOS interface
Number of fieldbus channels
1
2
Data transfer rate
2, 4, 8 or 16 Mbit/s
Synchronization
Synchronization of several cards via ribbon cable
Bus devices
254 max. per channel
Cycle time
all supported by SERCOS interface (from 62.5 µs)
Hardware diagnosis
1 LED per channel
Interface to the PC
Plug and Play PCI Interface 32 bit, direct access to DPRAM and SERCON816 register
Current consumption from the PCI bus
typically 180 mA
typically 285 mA
Dimensions
approx. 95 mm x 120 mm
Permissible ambient temperature during operation
0° to 55 °C

Ordering information

Order identifier
Product
FC7501
SERCOS interface PCI card, single-channel
FC7502
SERCOS interface PCI card, double-channel
Z1003
FSMA plug with knurled nut for 1000 µm plastic fiber
Z1100
Plastic optical fiber, single core, 1000 µm
Z1101
Plastic optical fiber, single core, 1000 µm with protective PU cladding and Kevlar strain relief
ZB7501
SERCOS master sync cable, for connecting SERCOS interface PCI cards of a PC