Driver installation

After plugin the FC11xx EtherCAT PCI Slave card the driver installation window (see fig. Driver Installation Window) will be appear. If a driver is already installed, then open this window from the Windows Device Manager dialog.

Driver installation 1:
Fig.16: Driver Installation Window

Select driver source path from a specific location (see fig. Select Driver Location) and choose the path where the files FC11xx.inf and TcMM.sys are located.

Driver installation 2:
Fig.17: Select Driver Location

After successful installation the device “FC1100 PCI Driver for ET9300” is listed in the Windows Device Manager (see fig. Windows Device Manager).

In case of the FC1121 card the name “FC1121 PCI Driver for ET9300” is shown.

Driver installation 3:
Fig.18: Windows Device Manager

The EtherCAT Slave Controller (ESC) is now accessible by using the library TcHelper.dll.