Interrupt

The Interrupts are controlled by the Interrupt function block

Interrupt Controller function block description

Address

Description

Value

0x01:0x00

Type of function

0x0011

0x03:0x02

Revision of function

 

0x07:0x04

reserved

 

0x0b:0x08

Base address offset of function

Offset to BAR0

0x0f:0x0c

Size of function on bytes

 

Sync0 (slot2) and PDI_ISR (slot1) states are shown in the Interrupt state register (see following table).

Interrupt State Register (0x00) description

Bit

Description

Reset value

0

Interrupt state of Slot 0

0

1

Interrupt state of Slot 1

0

…

…

…

15

Interrupt state of Slot 15

0

To enable the interrupt forward to the PCIe the following settings need to be done.

Interrupt Mask Register (0x08) description

Bit

Description

Reset value

0

Interrupt mask of Slot 0

0

1

Interrupt mask of Slot 1

0

…

…

…

15

Interrupt mask of Slot 15

0