Standard objects
Index 1000 Device type
| 
                   Index (hex)  | 
                   Name  | 
                   Meaning  | 
                   Data type  | 
                   Flags  | 
                   Default  | 
|---|---|---|---|---|---|
| 
                   1000:0  | 
                   Device type  | 
                   Device type of the EtherCAT slave: The Lo-Word contains the CoE profile used (5001). The Hi-Word contains the module profile according to the modular device profile.  | 
                   UINT32  | 
                   RO  | 
                   0x00001389 (5001dec)  | 
Index 1008 Device name
Index (hex)  | Name  | Meaning  | Data type  | Flags  | Default  | 
|---|---|---|---|---|---|
1008:0  | Device name  | Device name of the EtherCAT slave  | STRING  | RO  | EPP6090  | 
Index 1009 Hardware version
| 
                   Index (hex)  | 
                   Name  | 
                   Meaning  | 
                   Data type  | 
                   Flags  | 
                   Default  | 
|---|---|---|---|---|---|
| 
                   1009:0  | 
                   Hardware version  | 
                   Hardware version of the EtherCAT slave  | 
                   STRING  | 
                   RO  | 
                   variable  | 
Index 100A Software version
| 
                   Index (hex)  | 
                   Name  | 
                   Meaning  | 
                   Data type  | 
                   Flags  | 
                   Default  | 
|---|---|---|---|---|---|
| 
                   100A:0  | 
                   Software version  | 
                   Firmware version of the EtherCAT slave  | 
                   STRING  | 
                   RO  | 
                   variable  | 
Index 1018 Identity
Index (hex)  | Name  | Meaning  | Data type  | Flags  | Default  | 
|---|---|---|---|---|---|
1018:0  | Identity  | Information for identifying the slave  | UINT8  | RO  | 0x04 (4dec)  | 
1018:01  | Vendor ID  | Vendor ID of the EtherCAT slave  | UINT32  | RO  | 0x00000002 (2dec)  | 
1018:02  | Product code  | Product code of the EtherCAT slave  | UINT32  | RO  | 0x647742A8 (1685537448dec)  | 
1018:03  | Revision  | Revision number of the EtherCAT slave; the low word (bit 0-15) indicates the special terminal number, the high word (bit 16-31) refers to the device description  | UINT32  | RO  | 0  | 
1018:04  | Serial number  | Serial number of the EtherCAT slave; the low byte (bit 0-7) of the low word contains the year of production, the high byte (bit 8-15) of the low word contains the week of production, the high word (bit 16-31) is 0  | UINT32  | RO  | variable  | 
Index 10F0 Backup parameter handling
| 
                   Index (hex)  | 
                   Name  | 
                   Meaning  | 
                   Data type  | 
                   Flags  | 
                   Default  | 
|---|---|---|---|---|---|
| 
                   10F0:0  | 
                   Backup parameter handling  | 
                   Information for standardized loading and saving of backup entries  | 
                   UINT8  | 
                   RO  | 
                   0x01 (1dec)  | 
| 
                   10F0:01  | 
                   Checksum  | 
                   Checksum across all backup entries of the EtherCAT slave  | 
                   UINT32  | 
                   RO  | 
                   variable  | 
Index 1600 IO RxPDOPDO-Map
| 
                   Index (hex)  | 
                   Name  | 
                   Meaning  | 
                   Data type  | 
                   Flags  | 
                   Default  | 
|---|---|---|---|---|---|
| 
                   1600:0  | 
                   IO RxPDOPDO-Map  | 
                   PDO Mapping RxPDO 1  | 
                   UINT8  | 
                   RO  | 
                   0x02 (2dec)  | 
| 
                   1600:01  | 
                   SubIndex 001  | 
                   1. PDO Mapping entry (16 bits align)  | 
                   UINT32  | 
                   RO  | 
                   0x7000:11, 16  | 
| 
                   1600:02  | 
                   SubIndex 001  | 
                   2. PDO Mapping entry (16 bits align)  | 
                   UINT32  | 
                   RO  | 
                   0x7000:12, 16  | 
Index 1601..1604 IO RxPDOPDO-Map n = Ch.1..4
| 
                   Index (hex)  | 
                   Name  | 
                   Meaning  | 
                   Data type  | 
                   Flags  | 
                   Default  | 
|---|---|---|---|---|---|
| 
                   1601:0  | 
                   IO RxPDOPDO-Map Ch.1  | 
                   PDO Mapping RxPDO  | 
                   UINT8  | 
                   RO  | 
                   0x06 (6dec)  | 
| 
                   160n:01  | 
                   SubIndex 001  | 
                   Timer n start  | 
                   UINT32  | 
                   RO  | 
                   0x70n0:01, 1  | 
| 
                   160n:02  | 
                   SubIndex 002  | 
                   Timer n reset  | 
                   UINT32  | 
                   RO  | 
                   0x70n0:02, 1  | 
| 
                   160n:03  | 
                   SubIndex 003  | 
                   Padding bits  | 
                   UINT32  | 
                   RO  | 
                   0x0000:00, 5  | 
| 
                   160n:04  | 
                   SubIndex 004  | 
                   Counter n clk  | 
                   UINT32  | 
                   RO  | 
                   0x70n0:08, 1  | 
| 
                   160n:05  | 
                   SubIndex 005  | 
                   Counter n reset  | 
                   UINT32  | 
                   RO  | 
                   0x70n0:09, 1  | 
| 
                   160n:06  | 
                   SubIndex 006  | 
                   Padding bits  | 
                   UINT32  | 
                   RO  | 
                   0x0000:00, 7  | 
Index 1A00 IO TxPDOPDO-Map
| 
                   Index (hex)  | 
                   Name  | 
                   Meaning  | 
                   Data type  | 
                   Flags  | 
                   Default  | 
|---|---|---|---|---|---|
| 
                   1A00:0  | 
                   IO TxPDOPDO-Map Ch.1  | 
                   PDO Mapping TxPDO 1  | 
                   UINT8  | 
                   RO  | 
                   0x08 (8dec)  | 
| 
                   1A00:01  | 
                   SubIndex 001  | 
                   Padding bits  | 
                   UINT32  | 
                   RO  | 
                   0x0000:00, 2  | 
| 
                   1A00:02  | 
                   SubIndex 002  | 
                   Up  | 
                   UINT32  | 
                   RO  | 
                   0x6000:03, 1  | 
| 
                   1A030:03  | 
                   SubIndex 003  | 
                   Down  | 
                   UINT32  | 
                   RO  | 
                   0x6000:04, 1  | 
| 
                   1A00:04  | 
                   SubIndex 004  | 
                   Left  | 
                   UINT32  | 
                   RO  | 
                   0x6000:05, 1  | 
| 
                   1A00:05  | 
                   SubIndex 005  | 
                   Right  | 
                   UINT32  | 
                   RO  | 
                   0x6000:06, 1  | 
| 
                   1A00:06  | 
                   SubIndex 006  | 
                   Enter  | 
                   UINT32  | 
                   RO  | 
                   0x6000:07, 1  | 
| 
                   1A00:07  | 
                   SubIndex 007  | 
                   Padding bits  | 
                   UINT32  | 
                   RO  | 
                   0x0000:00, 8  | 
| 
                   1A00:08  | 
                   SubIndex 008  | 
                   Toggle bit  | 
                   UINT32  | 
                   RO  | 
                   0x6000:10, 1  | 
Index 1A01..1A04 IO TxPDOPDO-Map n = Ch.1..4
Index (hex)  | Name  | Meaning  | Data type  | Flags  | Default  | 
|---|---|---|---|---|---|
1A0n:0  | IO TxPDOPDO-Map Ch.2  | PDO Mapping TxPDO 2  | UINT8  | RO  | 0x04 (4dec)  | 
1A0n:01  | SubIndex 001  | Padding bits  | UINT32  | RO  | 0x0000:00, 14  | 
1A0n:02  | SubIndex 002  | Input cycle counter  | UINT32  | RO  | 0x60n0:0F, 2  | 
1A0n:03  | SubIndex 003  | Timer n  | UINT32  | RO  | 0x60n0:11, 32  | 
1A0n:04  | SubIndex 004  | Counter n  | UINT32  | RO  | 0x60n0:12, 32  | 
Index 1A05 UCP TxPDOe Map Inputs operating time
| 
                   Index (hex)  | 
                   Name  | 
                   Meaning  | 
                   Data type  | 
                   Flags  | 
                   Default  | 
|---|---|---|---|---|---|
| 
                   1A05:0  | 
                   TxPDOeState TxPDO-Map Device  | 
                   PDO Mapping TxPDO 5  | 
                   UINT8  | 
                   RO  | 
                   0x03 (3dec)  | 
| 
                   1A05:01  | 
                   SubIndex 001  | 
                   Padding bits  | 
                   UINT32  | 
                   RO  | 
                   0x0000:00, 14  | 
| 
                   1A05:02  | 
                   SubIndex 002  | 
                   Input cycle counter  | 
                   UINT32  | 
                   RO  | 
                   0xF600:0F, 2  | 
| 
                   1A05:03  | 
                   SubIndex 003  | 
                   Operating mode  | 
                   UINT32  | 
                   RO  | 
                   0xF600:11, 32  | 
Index 1C00 Sync manager type
| 
                   Index (hex)  | 
                   Name  | 
                   Meaning  | 
                   Data type  | 
                   Flags  | 
                   Default  | 
|---|---|---|---|---|---|
| 
                   1C00:0  | 
                   Sync manager type  | 
                   Using the sync managers  | 
                   UINT8  | 
                   RO  | 
                   0x04 (4dec)  | 
| 
                   1C00:01  | 
                   SubIndex 001  | 
                   Sync-Manager Type Channel 1: Mailbox Write  | 
                   UINT8  | 
                   RO  | 
                   0x01 (1dec)  | 
| 
                   1C00:02  | 
                   SubIndex 002  | 
                   Sync-Manager Type Channel 2: Mailbox Read  | 
                   UINT8  | 
                   RO  | 
                   0x02 (2dec)  | 
| 
                   1C00:03  | 
                   SubIndex 003  | 
                   Sync-Manager Type Channel 3: Process Data Write (Outputs)  | 
                   UINT8  | 
                   RO  | 
                   0x03 (3dec)  | 
| 
                   1C00:04  | 
                   SubIndex 004  | 
                   Sync-Manager Type Channel 4: Process Data Read (Inputs)  | 
                   UINT8  | 
                   RO  | 
                   0x04 (4dec)  | 
Index 1C12 RxPDO assign
Index (hex)  | Name  | Meaning  | Data type  | Flags  | Default  | 
|---|---|---|---|---|---|
1C12:0  | RxPDO assign  | PDO Assign Outputs  | UINT8  | RW  | 0x05 (5dec)  | 
1C32:01  | SubIndex 001  | 1. allocated RxPDO (contains the index of the associated RxPDO mapping object)  | UINT16  | RW  | 0x1600 (5632dec)  | 
1C12:02  | SubIndex 002  | 2. allocated RxPDO (contains the index of the associated RxPDO mapping object)  | UINT16  | RW  | 0x1601 (5633dec)  | 
1C12:03  | SubIndex 003  | 3. allocated RxPDO (contains the index of the associated RxPDO mapping object)  | UINT16  | RW  | 0x1602 (5634dec)  | 
1C12:04  | SubIndex 004  | 4. allocated RxPDO (contains the index of the associated RxPDO mapping object)  | UINT16  | RW  | 0x1603 (5635dec)  | 
1C12:05  | SubIndex 005  | 5. allocated RxPDO (contains the index of the associated RxPDO mapping object)  | UINT16  | RW  | 0x1604 (5636dec)  | 
Index 1C13 TxPDO assign
| 
                   Index (hex)  | 
                   Name  | 
                   Meaning  | 
                   Data type  | 
                   Flags  | 
                   Default  | 
|---|---|---|---|---|---|
| 
                   1C13:0  | 
                   TxPDO assign  | 
                   PDO Assign Inputs  | 
                   UINT8  | 
                   RW  | 
                   0x05 (5dec)  | 
| 
                   1C13:01  | 
                   SubIndex 001  | 
                   1. allocated TxPDO (contains the index of the associated TxPDO mapping object)  | 
                   UINT16  | 
                   RW  | 
                   0x1A00 (6656dec)  | 
| 
                   1C13:02  | 
                   SubIndex 002  | 
                   2. allocated TxPDO (contains the index of the associated TxPDO mapping object)  | 
                   UINT16  | 
                   RW  | 
                   0x1A01 (6657dec)  | 
| 
                   1C13:03  | 
                   SubIndex 003  | 
                   3. allocated TxPDO (contains the index of the associated TxPDO mapping object)  | 
                   UINT16  | 
                   RW  | 
                   0x1A02 (6658dec)  | 
| 
                   1C13:04  | 
                   SubIndex 004  | 
                   4. allocated TxPDO (contains the index of the associated TxPDO mapping object)  | 
                   UINT16  | 
                   RW  | 
                   0x1A03 (6659dec)  | 
| 
                   1C13:05  | 
                   SubIndex 005  | 
                   5. allocated TxPDO (contains the index of the associated TxPDO mapping object)  | 
                   UINT16  | 
                   RW  | 
                   0x1A04 (6660dec)  | 
| 
                   1C32:06  | 
                   SubIndex 006  | 
                   6. allocated TxPDO (contains the index of the associated TxPDO mapping object)  | 
                   UINT16  | 
                   RW  | 
                   0x1A05 (6661dec)  | 
Index 1C32 SM output parameter
| 
                   Index (hex)  | 
                   Name  | 
                   Meaning  | 
                   Data type  | 
                   Flags  | 
                   Default  | 
|---|---|---|---|---|---|
| 
                   1C32:0  | 
                   SM output parameter  | 
                   Synchronization parameters for the outputs  | 
                   UINT8  | 
                   RO  | 
                   0x20 (32dec)  | 
| 
                   1C32:01  | 
                   Sync mode  | 
                   Current synchronization mode: 
  | 
                   UINT16  | 
                   RW  | 
                   0x0000 (0dec)  | 
| 
                   1C32:02  | 
                   Cycle time  | 
                   Cycle time (in ns): 
  | 
                   UINT32  | 
                   RW  | 
                   0x000186A0 (100000dec)  | 
| 
                   1C32:03  | 
                   Shift time  | 
                   Time between SYNC0 event and output of the outputs (in ns, DC mode only)  | 
                   UINT32  | 
                   RO  | 
                   0x00000000 (0dec)  | 
| 
                   1C32:04  | 
                   Sync modes supported  | 
                   Supported synchronization modes: 
  | 
                   UINT16  | 
                   RO  | 
                   0xC007 (49159dec)  | 
| 
                   1C32:05  | 
                   Minimum cycle time  | 
                   Minimum cycle time (in ns)  | 
                   UINT32  | 
                   RO  | 
                   0x000186A0 (100000dec)  | 
| 
                   1C32:06  | 
                   Calc and copy time  | 
                   Minimum time between SYNC0 and SYNC1 event (in ns, DC mode only)  | 
                   UINT32  | 
                   RO  | 
                   0x00000000 (0dec)  | 
| 
                   1C32:08  | 
                   Command  | 
                  
 The entries 0x1C32:03, 0x1C32:05, 0x1C32:06, 0x1C32:09, 0x1C33:03, 0x1C33:06, 0x1C33:09 are updated with the maximum measured values.  | 
                   UINT16  | 
                   RW  | 
                   0x0000 (0dec)  | 
| 
                   1C32:09  | 
                   Delay time  | 
                   Time between SYNC1 event and output of the outputs (in ns, DC mode only)  | 
                   UINT32  | 
                   RO  | 
                   0x00000000 (0dec)  | 
| 
                   1C32:0B  | 
                   SM event missed counter  | 
                   Number of missed SM events in OPERATIONAL (DC mode only)  | 
                   UINT16  | 
                   RO  | 
                   0x0000 (0dec)  | 
| 
                   1C32:0C  | 
                   Cycle exceeded counter  | 
                   Number of occasions the cycle time was exceeded in OPERATIONAL (cycle was not completed in time or the next cycle began too early)  | 
                   UINT16  | 
                   RO  | 
                   0x0000 (0dec)  | 
| 
                   1C32:0D  | 
                   Shift too short counter  | 
                   Number of occasions that the interval between SYNC0 and SYNC1 event was too short (DC mode only)  | 
                   UINT16  | 
                   RO  | 
                   0x0000 (0dec)  | 
| 
                   1C32:20  | 
                   Sync error  | 
                   The synchronization was not correct in the last cycle (outputs were output too late; DC mode only)  | 
                   BOOLEAN  | 
                   RO  | 
                   0x00 (0dec)  | 
Index 1C33 SM input parameter
| 
                   Index (hex)  | 
                   Name  | 
                   Meaning  | 
                   Data type  | 
                   Flags  | 
                   Default  | 
|---|---|---|---|---|---|
| 
                   1C33:0  | 
                   SM input parameter  | 
                   Synchronization parameters for the inputs  | 
                   UINT8  | 
                   RO  | 
                   0x20 (32dec)  | 
| 
                   1C33:01  | 
                   Sync mode  | 
                   Current synchronization mode: 
  | 
                   UINT16  | 
                   RW  | 
                   0x0000 (0dec)  | 
| 
                   1C33:02  | 
                   Cycle time  | 
                   as 0x1C32:02  | 
                   UINT32  | 
                   RW  | 
                   0x000186A0 (100000dec)  | 
| 
                   1C33:03  | 
                   Shift time  | 
                   Time between SYNC0 event and reading of the inputs (in ns, only DC mode)  | 
                   UINT32  | 
                   RO  | 
                   0x00000000 (0dec)  | 
| 
                   1C33:04  | 
                   Sync modes supported  | 
                   Supported synchronization modes: 
  | 
                   UINT16  | 
                   RO  | 
                   0xC007 (49159dec)  | 
| 
                   1C33:05  | 
                   Minimum cycle time  | 
                   as 0x1C32:05  | 
                   UINT32  | 
                   RO  | 
                   0x000186A0 (100000dec)  | 
| 
                   1C33:06  | 
                   Calc and copy time  | 
                   Time between reading of the inputs and availability of the inputs for the master (in ns, only DC mode)  | 
                   UINT32  | 
                   RO  | 
                   0x00000000 (0dec)  | 
| 
                   1C33:08  | 
                   Command  | 
                   as 0x1C32:08  | 
                   UINT16  | 
                   RW  | 
                   0x0000 (0dec)  | 
| 
                   1C33:09  | 
                   Delay time  | 
                   Time between SYNC1 event and reading of the inputs (in ns, only DC mode)  | 
                   UINT32  | 
                   RO  | 
                   0x00000000 (0dec)  | 
| 
                   1C33:0B  | 
                   SM event missed counter  | 
                   as 0x1C32:11  | 
                   UINT16  | 
                   RO  | 
                   0x0000 (0dec)  | 
| 
                   1C33:0C  | 
                   Cycle exceeded counter  | 
                   as 0x1C32:12  | 
                   UINT16  | 
                   RO  | 
                   0x0000 (0dec)  | 
| 
                   1C33:0D  | 
                   Shift too short counter  | 
                   as 0x1C32:13  | 
                   UINT16  | 
                   RO  | 
                   0x0000 (0dec)  | 
| 
                   1C33:20  | 
                   Sync error  | 
                   as 0x11C32:32  | 
                   BOOLEAN  | 
                   RO  | 
                   0x00 (0dec)  |