Configuration objects

Index 1011 Restore default parameters

Index (hex)

Name

Meaning

Data type

Flags

Default

1011:0

Restore default parameters

Restore default settings

UINT8

RO

0x01 (1dec)

1011:01

SubIndex 001

If this object is set to "0x64616F6C" in the set value dialog, all backup objects are reset to their delivery state.

UINT32

RW

0x00000000 (0dec)

Index 8000 COM Settings Ch.1

Index (hex)

Name

Meaning

Data type

Flags

Default

8000:0

COM Settings Ch.1

 

UINT8

RO

0x1A (26dec)

8000:02

Enable XON/XOFF supported tx data

XON/XOFF is supported for send data

BOOLEAN

RW

0x00 (0dec)

8000:03

Enable XON/XOFF supported rx data

XON/XOFF is supported for receive data

BOOLEAN

RW

0x00 (0dec)

8000:04

Enable send FIFO data continuous

Continuous sending of data from the FIFO enabled

BOOLEAN

RW

0x00 (0dec)

8000:05

Enable transfer rate optimization

Switch on the transfer rate optimization

BOOLEAN

RW

0x01 (1dec)

8000:06

Enable half duplex

Half duplex for RS485 mode (this bit is not evaluated in RS232 and RS422 mode)

BOOLEAN

RW

0x00 (0dec)

0

Full duplex: The module monitors its transmitted data.

1

Half duplex: The module does not monitor the data that it has transmitted itself.

8000:07

Enable point to point connection (RS422)

0

The module is used in a bus structure in accordance with the RS485 standard.

BOOLEAN

RW

0x00 (0dec)

1

The module is used as a point-to-point connection (RS422)

8000:11

Baud rate

Baud Rate         

BIT4

RW

0x06 (6dec)

0x01

300 baud

0x02

600 baud

0x03

1200 baud

0x04

2400 baud

0x05

4800 baud

0x06

9600 baud

0x07

19200 baud

0x08

38400 baud

0x09

57600 baud

0x0A

115200 baud

8000:15

Data frame

Data frame / Stop bits        

BIT4

RW

0x03 (3dec)

0x01

7E1

0x02

7O1

0x03

8N1

0x04

8E1

0x05

8O1

0x09

7E2

0x0A

7O2

0x0B

8N2

0x0C

 8E2

0x0D

8O2

8000:19

Sensor Power Supply Output

0: Off
1: 5 V

BIT4

RW

5 V (1)

8000:1A

Rx buffer full notification

The value specifies the number of data in the receive FIFO, from which the bit "buffer full" is set.

UINT16

RW

0x0360 (864dec)

8000:1B

Explicit baudrate

In this object the desired baud rate can be entered directly as a number.

UINT32

RW

0x00002580 (9600dec)

Index F800 COM Settings

Index (hex)

Name

Meaning

Data type

Flags

Default

F800:0

COM Settings

 

UINT8

RO

0x01 (1dec)

F800:01

Interface Type Ch 1

0x00

RS232

BIT1

RW

0x00 (0dec)