D-sub sockets
Contact | EPP1816-0008 | EPP1816-3008 |
|---|---|---|
1 | Channel 1, Input 1 | US |
2 | Channel 1, Input 2 | GNDS |
3 | Channel 1, Input 3 | Channel 1, Input 1 |
4 | Channel 1, Input 4 | Channel 1, Input 2 |
5 | Channel 1, Input 5 | Channel 1, Input 3 |
6 | Channel 1, Input 6 | Channel 1, Input 4 |
7 | Channel 1, Input 7 | Channel 1, Input 5 |
8 | Channel 1, Input 8 | Channel 1, Input 6 |
9 | Channel 2, Input 1 | Channel 1, Input 7 |
10 | Channel 2, Input 2 | Channel 1, Input 8 |
11 | Channel 2, Input 3 | Channel 2, Input 1 |
12 | Channel 2, Input 4 | Channel 2, Input 2 |
13 | Channel 2, Input 5 | Channel 2, Input 3 |
14 | Channel 2, Input 6 | Channel 2, Input 4 |
15 | Channel 2, Input 7 | Channel 2, Input 5 |
16 | Channel 2, Input 8 | Channel 2, Input 6 |
17 | US | Channel 2, Input 7 |
18 | US | Channel 2, Input 8 |
19 | US | US |
20 | US | US |
21 | US | US |
22 | US | US |
23 | GNDS | GNDS |
24 | GNDS | GNDS |
25 | GNDS | GNDS |
1) US1 serves as sensor supply voltage. It is branched off from the US supply voltage.