Information objects
2n30 Amplifier Diag data Ch.x
- Index 2030: Amplifier Diag data Ch.1
- Index 2830: Amplifier Diag data Ch.2
Subindex (hex) | Name | Meaning | Data Type | Flags | Default |
|---|---|---|---|---|---|
0 | Amplifier Diag data Ch.x |
| USINT | RO | 0x11 (17dec) |
11 | Amplifier I2T temperature | I²T model utilization Unit: % | USINT | RO | - |
2n31 Motor Diag data Ch.x
- Index 2031: Motor Diag data Ch.1
- Index 2831: Motor Diag data Ch.2
Subindex (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
0 | Motor Diag data Ch.x |
| USINT | RO | 0x11 (17dec) |
11 | Motor I2T temperature | I²T model utilization Unit: % | USINT | RO | - |
2n40 Amplifier Info data Ch.x
- Index 2040: Amplifier Info data Ch.1
- Index 2840: Amplifier Info data Ch.2
Subindex (hex) | Name | Meaning | Data Type | Flags | Default |
|---|---|---|---|---|---|
0 | Amplifier Info data Ch.x |
| USINT | RO | 0x29 (41dec) |
17 | Cogging compensation supported |
| BOOL | RO | 0 |
18 | Dynamic Containers Supported | If “TRUE”: The drive controller supports dynamic containers (e.g. for Bode plot) | BOOL | RO | 1 |
28 | Actual motor brake state | Actual state of the motor brake (open, closed)
| USINT | RO | - |
29 | Missing dynoutput cycle counter | Error counter for dynamic containers | UDINT | RO | - |
2n42 Cycle Times Ch.x
- Index 2042: Cycle Times Ch.1
- Index 2842: Cycle Times Ch.2
Subindex (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
0 | Cycle Times Ch.x |
| USINT | RO | 0x8 (8dec) |
01 | PWM Cycle Time | Unit: ns | UDINT | RO | 0xF424 (62500dec) |
02 | Current Control Min Oversampling Cycle Time | Unit: ns | UDINT | RO | 0x7A12 (31250dec) |
03 | Velocity Control Min Oversampling Cycle Time | Unit: ns | UDINT | RO | 0xF424 (62500dec) |
04 | Position Control Min Oversampling Cycle Time | Unit: ns | UDINT | RO | 0xF424 (62500dec) |
05 | Current Control Cycle Time | Unit: ns | UDINT | RO | 0x7A12 (31,250dec) |
06 | Velocity Control Cycle Time | Unit: ns | UDINT | RO | 0xF424 (62500dec) |
07 | Position Control Cycle Time | Unit: ns | UDINT | RO | 0xF424 (62500dec) |
08 | DMC Cycle Time | Unit: ns | UDINT | RO | 0xF424 (62,500dec) |
2n5A Feedback Info Data Ch.x
- Index 205A: Feedback Info Data Ch.1
- Index 285A: Feedback Info Data Ch.2
Subindex (hex) | Name | Meaning | Data Type | Flags | Default |
|---|---|---|---|---|---|
0 | Feedback Info Data Ch.x |
| USINT | RO | 0x1 (1dec) |
01 | Raw Position |
| ULINT | RO | 0x0 (0dec) |
F900 DRV Info data
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
F900:0 | DRV Info data |
| USINT | RO | 0x12 (18dec) |
F900:11 | Amplifier temperature | Internal temperature of the box module. Unit: 0.1°C | INT | RO | - |
F900:12 | DC link voltage | Measured value of the DC link voltage. Unit: mV | UDINT | RO | - |
F913 DRV Device Info data
Index (hex) | Name | Meaning | Data Type | Flags | Default |
|---|---|---|---|---|---|
F913:0 | DRV Device Info data |
| USINT | RO | 0x6 (6dec) |
F913:01 | HW config | - | STRING(32) | RO | - |
F913:03 | FW info | - | STRING(32) | RO | - |
F913:04 | DMC version | - | STRING(32) | RO | - |
F913:06 | Device Type | - | UDINT | RO | - |