Brake control

The drive controller can automatically activate a holding brake integrated into the motor based on the drive's operating state:

In addition, the brakes can be controlled independently of the drive controller (Enable manual override).

Enable brake control

In parameter 2004:18/2804:18 (channel 1/2), Brake Output Features, you can enable the brake control and choose the digital output to be used for brake control.

Configure

Configure the brake control using the parameters in objects 0x2004/0x2804, Brake Settings Ch.1/2; see chapter Configuration objects.

Diagnostics

The requested state of the motor brake can be read via the Actual motor brake state parameter using the CoE or process data. This object also reflects the effects of all override functions. However, the drive controller cannot verify whether the motor brake is actually energized and open; in other words, cable breakage, short circuits, etc., are not detectable in this object.

Error reaction

In the event of a fault or an emergency shutdown, after receiving a request to stop the motor, the drive controller waits until the motor has actually come to a standstill before applying the brake. A configurable maximum delay time (Emergency application timeout) limits the time until the brake is applied.