Information objects

2n30 Amplifier Diag data Ch.x

Subindex (hex)

Name

Meaning

Data Type

Flags

Default

0

Amplifier Diag data Ch.x

 

USINT

RO

0x11 (17dec)

11

Amplifier I2T temperature

I²T model utilization

Unit: %

USINT

RO

-

2n31 Motor Diag data Ch.x

Subindex (hex)

Name

Meaning

Data type

Flags

Default

0

Motor Diag data Ch.x

 

USINT

RO

0x11 (17dec)

11

Motor I2T temperature

I²T model utilization

Unit: %

USINT

RO

-

2n40 Amplifier Info data Ch.x

Subindex (hex)

Name

Meaning

Data Type

Flags

Default

0

Amplifier Info data Ch.x

 

USINT

RO

0x29 (41dec)

17

Cogging compensation supported

  • If “TRUE”: The drive controller supports cogging compensation and the required calibration data is available.
  • If “FALSE”: Cogging compensation is not possible (not supported and/or no calibration data)

BOOL

RO

0

18

Dynamic Containers Supported

If “TRUE”: The drive controller supports dynamic containers (e.g. for Bode plot)

BOOL

RO

1

28

Actual motor brake state

Actual state of the motor brake (open, closed)

  • 0: Motor brake applied
  • 1: Motor brake released

USINT

RO

-

29

Missing dynoutput cycle counter

Error counter for dynamic containers

UDINT

RO

-

2n42 Cycle Times Ch.x

Subindex (hex)

Name

Meaning

Data type

Flags

Default

0

Cycle Times Ch.x

 

USINT

RO

0x8 (8dec)

01

PWM Cycle Time

Unit: ns

UDINT

RO

0xF424 (62500dec)

02

Current Control Min Oversampling Cycle Time

Unit: ns

UDINT

RO

0x7A12 (31250dec)

03

Velocity Control Min Oversampling Cycle Time

Unit: ns

UDINT

RO

0xF424 (62500dec)

04

Position Control Min Oversampling Cycle Time

Unit: ns

UDINT

RO

0xF424 (62500dec)

05

Current Control Cycle Time

Unit: ns

UDINT

RO

0x7A12 (31,250dec)

06

Velocity Control Cycle Time

Unit: ns

UDINT

RO

0xF424 (62500dec)

07

Position Control Cycle Time

Unit: ns

UDINT

RO

0xF424 (62500dec)

08

DMC Cycle Time

Unit: ns

UDINT

RO

0xF424 (62,500dec)

2n5A Feedback Info Data Ch.x

Subindex (hex)

Name

Meaning

Data Type

Flags

Default

0

Feedback Info Data Ch.x

 

USINT

RO

0x1 (1dec)

01

Raw Position

 

ULINT

RO

0x0 (0dec)

F900 DRV Info data

Index (hex)

Name

Meaning

Data type

Flags

Default

F900:0

DRV Info data

 

USINT

RO

0x12 (18dec)

F900:11

Amplifier temperature

Internal temperature of the box module.

Unit: 0.1°C

INT

RO

-

F900:12

DC link voltage

Measured value of the DC link voltage.

Unit: mV

UDINT

RO

-

F913 DRV Device Info data

Index (hex)

Name

Meaning

Data Type

Flags

Default

F913:0

DRV Device Info data

 

USINT

RO

0x6 (6dec)

F913:01

HW config

-

STRING(32)

RO

-

F913:03

FW info

-

STRING(32)

RO

-

F913:04

DMC version

-

STRING(32)

RO

-

F913:06

Device Type

-

UDINT

RO

-