Standard objects

1000 Device type

Index (hex)

Name

Meaning

Data type

Flags

Default

1000:0

Device type

EtherCAT slave device type: the low word contains the CoE profile used (402dec).

UDINT

RO

0x00020192 (131474dec)

1001 Error register

Index (hex)

Name

Meaning

Data Type

Flags

Default

1001:0

Error register

-

USINT

RO

-

1008 Device name

Index (hex)

Name

Meaning

Data Type

Flags

Default

1008:0

Device name

Device name of the EtherCAT slave

STRING(19)

RO

-

1009 Hardware version

Index (hex)

Name

Meaning

Data Type

Flags

Default

1009:0

Hardware version

Hardware version of the EtherCAT slave

STRING(2)

RO

-

100A Software version

Index (hex)

Name

Meaning

Data Type

Flags

Default

100A:0

Software version

Firmware version of the EtherCAT slave

STRING(2)

RO

-

100B Bootloader version

Index (hex)

Name

Meaning

Data Type

Flags

Default

100B:0

Bootloader version

-

STRING(32)

RO

-

1011 Restore default parameters

Index (hex)

Name

Meaning

Data Type

Flags

Default

1011:0

Restore default parameters

Restoring the default parameters

USINT

RO

0x1 (1dec)

1018 Identity

Index (hex)

Name

Meaning

Data Type

Flags

Default

1018:0

Identity

Information for identifying the slave

USINT

RO

0x4 (4dec)

1018:01

Vendor ID

Vendor ID of the EtherCAT slave

UDINT

RO

0x2 (2dec)

1018:02

Product code

Product code of the EtherCAT slave

UDINT

RO

0x1CF44052 (485769298dec)

1018:03

Revision

Revision number of the EtherCAT slave; the Low Word (bit 0-15) indicates the special terminal number, the High Word (bit 16-31) refers to the device description

UDINT

RO

-

1018:04

Serial number

Serial number of the EtherCAT slave; the low byte (bit 0-7) of the low word contains the year of production, the high byte (bit 8-15) of the low word contains the week of production, the high word (bit 16-31) is 0

UDINT

RO

-

1020 Device Statistics

Index (hex)

Name

Meaning

Data Type

Flags

Default

1020:0

Device Statistics

 

USINT

RO

0x3 (3dec)

1020:01

Time since power on

Operating time since last power-on in s

UDINT

RO

-

1020:02

Total time powered

Total operating time in s

UDINT

RO

-

1020:03

Number of power cycles

Number of power cycles

UDINT

RO

-

10E2 Manufacturer-specific Identification Code

Index (hex)

Name

Meaning

Data Type

Flags

Default

10E2:0

Manufacturer-specific Identification Code

eBIC

USINT

RO

0x1 (1dec)

10F0 Backup parameter handling

Index (hex)

Name

Meaning

Data Type

Flags

Default

10F0:0

Backup parameter handling

 

USINT

RO

0x1 (1dec)

10F0:01

Checksum

Checksum across all backup entries of the EtherCAT slave

UDINT

RO

-

10F3 Diagnosis History

Index (hex)

Name

Meaning

Data Type

Flags

Default

10F3:0

Diagnosis History

 

USINT

RO

0x37 (55dec)

10F3:01

Maximum Messages

Maximum number of stored messages

USINT

RO

-

10F3:02

Newest Message

Subindex of the newest message

USINT

RO

-

10F3:03

Newest Acknowledged Message

Subindex of the last acknowledged message

USINT

RW

-

10F3:04

New Messages Available

Indicates that a new message is available

BOOL

RO

-

10F3:05

Flags

-

UINT

RW

-

10F3:06

Diagnosis Message 001

-

ARRAY [0..31] OF BYTE

RO

-

10F3:07

Diagnosis Message 002

-

ARRAY [0..31] OF BYTE

RO

-

10F3:08

Diagnosis Message 003

-

ARRAY [0..31] OF BYTE

RO

-

…

…

…

…

…

…

10F3:35

Diagnosis Message 048

-

ARRAY [0..31] OF BYTE

RO

-

10F3:36

Diagnosis Message 049

-

ARRAY [0..31] OF BYTE

RO

-

10F3:37

Diagnosis Message 050

-

ARRAY [0..31] OF BYTE

RO

-

10F8 Timestamp Object

Index (hex)

Name

Meaning

Data Type

Flags

Default

10F8:0

Timestamp Object

-

ULINT

RO

-

1460 DS402 RxPDO-Par Outputs Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1460:0

DS402 RxPDO-Par Outputs Ch.1

 

USINT

RO

0x6 (6dec)

1460:06

Exclude RxPDOs

 

ARRAY [0..1] OF BYTE

RO

[6116]

1461 DS402 RxPDO-Par Outputs 32 Bit Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1461:0

DS402 RxPDO-Par Outputs 32 Bit Ch.1

 

USINT

RO

0x6 (6dec)

1461:06

Exclude RxPDOs

 

ARRAY [0..1] OF BYTE

RO

[6016]

14E0 DS402 RxPDO-Par Outputs Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

14E0:0

DS402 RxPDO-Par Outputs Ch.2

 

USINT

RO

0x6 (6dec)

14E0:06

Exclude RxPDOs

 

ARRAY [0..1] OF BYTE

RO

[e116]

14E1 DS402 RxPDO-Par Outputs 32 Bit Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

14E1:0

DS402 RxPDO-Par Outputs 32 Bit Ch.2

 

USINT

RO

0x6 (6dec)

14E1:06

Exclude RxPDOs

 

ARRAY [0..1] OF BYTE

RO

[e016]

1600 DS402 RxPDO-Map Controlword Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1600:0

DS402 RxPDO-Map Controlword Ch.1

 

USINT

RO

0x1 (1dec)

1600:01

SubIndex 001

 

UDINT

RO

0x6040:00, 16

1601 DS402 RxPDO-Map Target velocity Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1601:0

DS402 RxPDO-Map Target velocity Ch.1

 

USINT

RO

0x1 (1dec)

1601:01

SubIndex 001

 

UDINT

RO

0x60ff:00, 32

1602 DS402 RxPDO-Map Target torque Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1602:0

DS402 RxPDO-Map Target torque Ch.1

 

USINT

RO

0x1 (1dec)

1602:01

SubIndex 001

 

UDINT

RO

0x6071:00, 16

1603 DS402 RxPDO-Map Commutation angle Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1603:0

DS402 RxPDO-Map Commutation angle Ch.1

 

USINT

RO

0x1 (1dec)

1603:01

SubIndex 001

 

UDINT

RO

0x60ea:00, 16

1604 DS402 RxPDO-Map Torque limitation Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1604:0

DS402 RxPDO-Map Torque limitation Ch.1

 

USINT

RO

0x1 (1dec)

1604:01

SubIndex 001

 

UDINT

RO

0x6072:00, 16

1605 DS402 RxPDO-Map Torque offset Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1605:0

DS402 RxPDO-Map Torque offset Ch.1

 

USINT

RO

0x1 (1dec)

1605:01

SubIndex 001

 

UDINT

RO

0x60b2:00, 16

1606 DS402 RxPDO-Map Target position Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1606:0

DS402 RxPDO-Map Target position Ch.1

 

USINT

RO

0x1 (1dec)

1606:01

SubIndex 001

 

UDINT

RO

0x607a:00, 32

1607 DS402 RxPDO-Map Touch probe function Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1607:0

DS402 RxPDO-Map Touch probe function Ch.1

 

USINT

RO

0x1 (1dec)

1607:01

SubIndex 001

 

UDINT

RO

0x60b8:00, 16

1608 DS402 RxPDO-Map Modes of operation Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1608:0

DS402 RxPDO-Map Modes of operation Ch.1

 

USINT

RO

0x1 (1dec)

1608:01

SubIndex 001

 

UDINT

RO

0x6060:00, 8

1609 DS402 RxPDO-Map Velocity offset Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1609:0

DS402 RxPDO-Map Velocity offset Ch.1

 

USINT

RO

0x1 (1dec)

1609:01

SubIndex 001

 

UDINT

RO

0x60b1:00, 32

160A DS402 RxPDO-Map Positive Torque limit value Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

160A:0

DS402 RxPDO-Map Positive Torque limit value Ch.1

 

USINT

RO

0x1 (1dec)

160A:01

SubIndex 001

 

UDINT

RO

0x60e0:00, 16

160B DS402 RxPDO-Map Negative Torque limit value Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

160B:0

DS402 RxPDO-Map Negative Torque limit value Ch.1

 

USINT

RO

0x1 (1dec)

160B:01

SubIndex 001

 

UDINT

RO

0x60e1:00, 16

1610 DS402 RxPDO-Map Digital Outputs Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1610:0

DS402 RxPDO-Map Digital Outputs Ch.1

 

USINT

RO

0x1 (1dec)

1610:01

SubIndex 001

PDO Mapping Entry for “Digital Outputs”.

UDINT

RO

0x60fe:01, 32

1660 DS402 RxPDO-Map Outputs Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1660:0

DS402 RxPDO-Map Outputs Ch.1

 

USINT

RO

0x12 (18dec)

1660:01

SubIndex 001

 

UDINT

RO

0x0000:00, 1

1660:02

SubIndex 002

PDO Mapping Entry for “DMC__FeedbackControl__Enable latch extern on positive edge”.

UDINT

RO

0x2104:02, 1

1660:03

SubIndex 003

PDO Mapping Entry for “DMC__FeedbackControl__Set counter”.

UDINT

RO

0x2104:03, 1

1660:04

SubIndex 004

PDO Mapping Entry for “DMC__FeedbackControl__Enable latch extern on negative edge”.

UDINT

RO

0x2104:04, 1

1660:05

SubIndex 005

 

UDINT

RO

0x0000:00, 12

1660:06

SubIndex 006

PDO Mapping Entry for “DMC__DriveControl__Enable”.

UDINT

RO

0x2104:11, 1

1660:07

SubIndex 007

PDO Mapping Entry for “DMC__DriveControl__Reset”.

UDINT

RO

0x2104:12, 1

1660:08

SubIndex 008

 

UDINT

RO

0x0000:00, 14

1660:09

SubIndex 009

PDO Mapping Entry for “DMC__PositioningControl__Execute”.

UDINT

RO

0x2104:21, 1

1660:0A

SubIndex 010

PDO Mapping Entry for “DMC__PositioningControl__Emergency stop”.

UDINT

RO

0x2104:22, 1

1660:0B

SubIndex 011

 

UDINT

RO

0x0000:00, 14

1660:0C

SubIndex 012

PDO Mapping Entry for “DMC__Set counter value”.

UDINT

RO

0x2104:31, 64

1660:0D

SubIndex 013

PDO Mapping Entry for “DMC__Target position”.

UDINT

RO

0x2104:32, 64

1660:0E

SubIndex 014

PDO Mapping Entry for “DMC__Target velocity”.

UDINT

RO

0x2104:33, 16

1660:0F

SubIndex 015

PDO Mapping Entry for “DMC__Start type”.

UDINT

RO

0x2104:34, 16

1660:10

SubIndex 016

PDO Mapping Entry for “DMC__Target acceleration”.

UDINT

RO

0x2104:35, 16

1660:11

SubIndex 017

PDO Mapping Entry for “DMC__Target deceleration”.

UDINT

RO

0x2104:36, 16

1660:12

SubIndex 018

 

UDINT

RO

0x0000:00, 80

1661 DS402 RxPDO-Map Outputs 32 Bit Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1661:0

DS402 RxPDO-Map Outputs 32 Bit Ch.1

 

USINT

RO

0x14 (20dec)

1661:01

SubIndex 001

 

UDINT

RO

0x0000:00, 1

1661:02

SubIndex 002

PDO Mapping Entry for “DMC__FeedbackControl__Enable latch extern on positive edge”.

UDINT

RO

0x2104:02, 1

1661:03

SubIndex 003

PDO Mapping Entry for “DMC__FeedbackControl__Set counter”.

UDINT

RO

0x2104:03, 1

1661:04

SubIndex 004

PDO Mapping Entry for “DMC__FeedbackControl__Enable latch extern on negative edge”.

UDINT

RO

0x2104:04, 1

1661:05

SubIndex 005

 

UDINT

RO

0x0000:00, 12

1661:06

SubIndex 006

PDO Mapping Entry for “DMC__DriveControl__Enable”.

UDINT

RO

0x2104:11, 1

1661:07

SubIndex 007

PDO Mapping Entry for “DMC__DriveControl__Reset”.

UDINT

RO

0x2104:12, 1

1661:08

SubIndex 008

 

UDINT

RO

0x0000:00, 14

1661:09

SubIndex 009

PDO Mapping Entry for “DMC__PositioningControl__Execute”.

UDINT

RO

0x2104:21, 1

1661:0A

SubIndex 010

PDO Mapping Entry for “DMC__PositioningControl__Emergency stop”.

UDINT

RO

0x2104:22, 1

1661:0B

SubIndex 011

 

UDINT

RO

0x0000:00, 14

1661:0C

SubIndex 012

PDO Mapping Entry for “DMC__Set counter value”.

UDINT

RO

0x2104:31, 32

1661:0D

SubIndex 013

 

UDINT

RO

0x0000:00, 32

1661:0E

SubIndex 014

PDO Mapping Entry for “DMC__Target position”.

UDINT

RO

0x2104:32, 32

1661:0F

SubIndex 015

 

UDINT

RO

0x0000:00, 32

1661:10

SubIndex 016

PDO Mapping Entry for “DMC__Target velocity”.

UDINT

RO

0x2104:33, 16

1661:11

SubIndex 017

PDO Mapping Entry for “DMC__Start type”.

UDINT

RO

0x2104:34, 16

1661:12

SubIndex 018

PDO Mapping Entry for “DMC__Target acceleration”.

UDINT

RO

0x2104:35, 16

1661:13

SubIndex 019

PDO Mapping Entry for “DMC__Target deceleration”.

UDINT

RO

0x2104:36, 16

1661:14

SubIndex 020

 

UDINT

RO

0x0000:00, 80

1670 DS402 RxPDO-Map Dynamic Outputs Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1670:0

DS402 RxPDO-Map Dynamic Outputs Ch.1

 

USINT

RO

0x1 (1dec)

1670:01

SubIndex 001

PDO Mapping Entry for “Dynoutput cycle counter”.

UDINT

RW

0x200b:04, 8

1670:02

SubIndex 002

-

UDINT

RW

-

1670:03

SubIndex 003

-

UDINT

RW

-

…

…

…

…

…

…

1670:FD

SubIndex 253

-

UDINT

RW

-

1670:FE

SubIndex 254

-

UDINT

RW

-

1670:FF

SubIndex 255

-

UDINT

RW

-

1680 DS402 RxPDO-Map Controlword Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1680:0

DS402 RxPDO-Map Controlword Ch.2

 

USINT

RO

0x1 (1dec)

1680:01

SubIndex 001

 

UDINT

RO

0x6840:00, 16

1681 DS402 RxPDO-Map Target velocity Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1681:0

DS402 RxPDO-Map Target velocity Ch.2

 

USINT

RO

0x1 (1dec)

1681:01

SubIndex 001

 

UDINT

RO

0x68ff:00, 32

1682 DS402 RxPDO-Map Target torque Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1682:0

DS402 RxPDO-Map Target torque Ch.2

 

USINT

RO

0x1 (1dec)

1682:01

SubIndex 001

 

UDINT

RO

0x6871:00, 16

1683 DS402 RxPDO-Map Commutation angle Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1683:0

DS402 RxPDO-Map Commutation angle Ch.2

 

USINT

RO

0x1 (1dec)

1683:01

SubIndex 001

 

UDINT

RO

0x68ea:00, 16

1684 DS402 RxPDO-Map Torque limitation Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1684:0

DS402 RxPDO-Map Torque limitation Ch.2

 

USINT

RO

0x1 (1dec)

1684:01

SubIndex 001

 

UDINT

RO

0x6872:00, 16

1685 DS402 RxPDO-Map Torque offset Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1685:0

DS402 RxPDO-Map Torque offset Ch.2

 

USINT

RO

0x1 (1dec)

1685:01

SubIndex 001

 

UDINT

RO

0x68b2:00, 16

1686 DS402 RxPDO-Map Target position Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1686:0

DS402 RxPDO-Map Target position Ch.2

 

USINT

RO

0x1 (1dec)

1686:01

SubIndex 001

 

UDINT

RO

0x687a:00, 32

1687 DS402 RxPDO-Map Touch probe function Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1687:0

DS402 RxPDO-Map Touch probe function Ch.2

 

USINT

RO

0x1 (1dec)

1687:01

SubIndex 001

 

UDINT

RO

0x68b8:00, 16

1688 DS402 RxPDO-Map Modes of operation Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1688:0

DS402 RxPDO-Map Modes of operation Ch.2

 

USINT

RO

0x1 (1dec)

1688:01

SubIndex 001

 

UDINT

RO

0x6860:00, 8

1689 DS402 RxPDO-Map Velocity offset Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1689:0

DS402 RxPDO-Map Velocity offset Ch.2

 

USINT

RO

0x1 (1dec)

1689:01

SubIndex 001

 

UDINT

RO

0x68b1:00, 32

168A DS402 RxPDO-Map Positive Torque limit value Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

168A:0

DS402 RxPDO-Map Positive Torque limit value Ch.2

 

USINT

RO

0x1 (1dec)

168A:01

SubIndex 001

 

UDINT

RO

0x68e0:00, 16

168B DS402 RxPDO-Map Negative Torque limit value Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

168B:0

DS402 RxPDO-Map Negative Torque limit value Ch.2

 

USINT

RO

0x1 (1dec)

168B:01

SubIndex 001

 

UDINT

RO

0x68e1:00, 16

1690 DS402 RxPDO-Map Digital Outputs Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1690:0

DS402 RxPDO-Map Digital Outputs Ch.2

 

USINT

RO

0x1 (1dec)

1690:01

SubIndex 001

PDO Mapping Entry for “Digital Outputs”.

UDINT

RO

0x68fe:01, 32

16E0 DS402 RxPDO-Map Outputs Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

16E0:0

DS402 RxPDO-Map Outputs Ch.2

 

USINT

RO

0x12 (18dec)

16E0:01

SubIndex 001

 

UDINT

RO

0x0000:00, 1

16E0:02

SubIndex 002

PDO Mapping Entry for “DMC__FeedbackControl__Enable latch extern on positive edge”.

UDINT

RO

0x2904:02, 1

16E0:03

SubIndex 003

PDO Mapping Entry for “DMC__FeedbackControl__Set counter”.

UDINT

RO

0x2904:03, 1

16E0:04

SubIndex 004

PDO Mapping Entry for “DMC__FeedbackControl__Enable latch extern on negative edge”.

UDINT

RO

0x2904:04, 1

16E0:05

SubIndex 005

 

UDINT

RO

0x0000:00, 12

16E0:06

SubIndex 006

PDO Mapping Entry for “DMC__DriveControl__Enable”.

UDINT

RO

0x2904:11, 1

16E0:07

SubIndex 007

PDO Mapping Entry for “DMC__DriveControl__Reset”.

UDINT

RO

0x2904:12, 1

16E0:08

SubIndex 008

 

UDINT

RO

0x0000:00, 14

16E0:09

SubIndex 009

PDO Mapping Entry for “DMC__PositioningControl__Execute”.

UDINT

RO

0x2904:21, 1

16E0:0A

SubIndex 010

PDO Mapping Entry for “DMC__PositioningControl__Emergency stop”.

UDINT

RO

0x2904:22, 1

16E0:0B

SubIndex 011

 

UDINT

RO

0x0000:00, 14

16E0:0C

SubIndex 012

PDO Mapping Entry for “DMC__Set counter value”.

UDINT

RO

0x2904:31, 64

16E0:0D

SubIndex 013

PDO Mapping Entry for “DMC__Target position”.

UDINT

RO

0x2904:32, 64

16E0:0E

SubIndex 014

PDO Mapping Entry for “DMC__Target velocity”.

UDINT

RO

0x2904:33, 16

16E0:0F

SubIndex 015

PDO Mapping Entry for “DMC__Start type”.

UDINT

RO

0x2904:34, 16

16E0:10

SubIndex 016

PDO Mapping Entry for “DMC__Target acceleration”.

UDINT

RO

0x2904:35, 16

16E0:11

SubIndex 017

PDO Mapping Entry for “DMC__Target deceleration”.

UDINT

RO

0x2904:36, 16

16E0:12

SubIndex 018

 

UDINT

RO

0x0000:00, 80

16E1 DS402 RxPDO-Map Outputs 32 Bit Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

16E1:0

DS402 RxPDO-Map Outputs 32 Bit Ch.2

 

USINT

RO

0x14 (20dec)

16E1:01

SubIndex 001

 

UDINT

RO

0x0000:00, 1

16E1:02

SubIndex 002

PDO Mapping Entry for “DMC__FeedbackControl__Enable latch extern on positive edge”.

UDINT

RO

0x2904:02, 1

16E1:03

SubIndex 003

PDO Mapping Entry for “DMC__FeedbackControl__Set counter”.

UDINT

RO

0x2904:03, 1

16E1:04

SubIndex 004

PDO Mapping Entry for “DMC__FeedbackControl__Enable latch extern on negative edge”.

UDINT

RO

0x2904:04, 1

16E1:05

SubIndex 005

 

UDINT

RO

0x0000:00, 12

16E1:06

SubIndex 006

PDO Mapping Entry for “DMC__DriveControl__Enable”.

UDINT

RO

0x2904:11, 1

16E1:07

SubIndex 007

PDO Mapping Entry for “DMC__DriveControl__Reset”.

UDINT

RO

0x2904:12, 1

16E1:08

SubIndex 008

 

UDINT

RO

0x0000:00, 14

16E1:09

SubIndex 009

PDO Mapping Entry for “DMC__PositioningControl__Execute”.

UDINT

RO

0x2904:21, 1

16E1:0A

SubIndex 010

PDO Mapping Entry for “DMC__PositioningControl__Emergency stop”.

UDINT

RO

0x2904:22, 1

16E1:0B

SubIndex 011

 

UDINT

RO

0x0000:00, 14

16E1:0C

SubIndex 012

PDO Mapping Entry for “DMC__Set counter value”.

UDINT

RO

0x2904:31, 32

16E1:0D

SubIndex 013

 

UDINT

RO

0x0000:00, 32

16E1:0E

SubIndex 014

PDO Mapping Entry for “DMC__Target position”.

UDINT

RO

0x2904:32, 32

16E1:0F

SubIndex 015

 

UDINT

RO

0x0000:00, 32

16E1:10

SubIndex 016

PDO Mapping Entry for “DMC__Target velocity”.

UDINT

RO

0x2904:33, 16

16E1:11

SubIndex 017

PDO Mapping Entry for “DMC__Start type”.

UDINT

RO

0x2904:34, 16

16E1:12

SubIndex 018

PDO Mapping Entry for “DMC__Target acceleration”.

UDINT

RO

0x2904:35, 16

16E1:13

SubIndex 019

PDO Mapping Entry for “DMC__Target deceleration”.

UDINT

RO

0x2904:36, 16

16E1:14

SubIndex 020

 

UDINT

RO

0x0000:00, 80

16F0 DS402 RxPDO-Map Dynamic Outputs Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

16F0:0

DS402 RxPDO-Map Dynamic Outputs Ch.2

 

USINT

RO

0x1 (1dec)

16F0:01

SubIndex 001

PDO Mapping Entry for “Dynoutput cycle counter”.

UDINT

RW

0x280b:04, 8

16F0:02

SubIndex 002

-

UDINT

RW

-

16F0:03

SubIndex 003

-

UDINT

RW

-

…

…

…

…

…

…

16F0:FD

SubIndex 253

-

UDINT

RW

-

16F0:FE

SubIndex 254

-

UDINT

RW

-

16F0:FF

SubIndex 255

-

UDINT

RW

-

1860 DS402 TxPDO-Par Inputs Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1860:0

DS402 TxPDO-Par Inputs Ch.1

 

USINT

RO

0x6 (6dec)

1860:06

Exclude TxPDOs

 

ARRAY [0..1] OF BYTE

RO

[611a]

1861 DS402 TxPDO-Par Inputs 32 Bit Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1861:0

DS402 TxPDO-Par Inputs 32 Bit Ch.1

 

USINT

RO

0x6 (6dec)

1861:06

Exclude TxPDOs

 

ARRAY [0..1] OF BYTE

RO

[601a]

18E0 DS402 TxPDO-Par Inputs Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

18E0:0

DS402 TxPDO-Par Inputs Ch.2

 

USINT

RO

0x6 (6dec)

18E0:06

Exclude TxPDOs

 

ARRAY [0..1] OF BYTE

RO

[e11a]

18E1 DS402 TxPDO-Par Inputs 32 Bit Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

18E1:0

DS402 TxPDO-Par Inputs 32 Bit Ch.2

 

USINT

RO

0x6 (6dec)

18E1:06

Exclude TxPDOs

 

ARRAY [0..1] OF BYTE

RO

[e01a]

1A00 DS402 TxPDO-Map Position actual value Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A00:0

DS402 TxPDO-Map Position actual value Ch.1

 

USINT

RO

0x1 (1dec)

1A00:01

SubIndex 001

 

UDINT

RO

0x6064:00, 32

1A01 DS402 TxPDO-Map Statusword Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A01:0

DS402 TxPDO-Map Statusword Ch.1

 

USINT

RO

0x1 (1dec)

1A01:01

SubIndex 001

 

UDINT

RO

0x6041:00, 16

1A02 DS402 TxPDO-Map Velocity actual value Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A02:0

DS402 TxPDO-Map Velocity actual value Ch.1

 

USINT

RO

0x1 (1dec)

1A02:01

SubIndex 001

 

UDINT

RO

0x606c:00, 32

1A03 DS402 TxPDO-Map Torque actual value Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A03:0

DS402 TxPDO-Map Torque actual value Ch.1

 

USINT

RO

0x1 (1dec)

1A03:01

SubIndex 001

 

UDINT

RO

0x6077:00, 16

1A04 DS402 TxPDO-Map Info data 1 Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A04:0

DS402 TxPDO-Map Info data 1 Ch.1

 

USINT

RO

0x1 (1dec)

1A04:01

SubIndex 001

PDO Mapping Entry for “Info data 1”.

UDINT

RW

0x2008:01, 16

1A04:02

SubIndex 002

-

UDINT

RW

-

1A04:03

SubIndex 003

-

UDINT

RW

-

1A04:04

SubIndex 004

-

UDINT

RW

-

1A04:05

SubIndex 005

-

UDINT

RW

-

1A04:06

SubIndex 006

-

UDINT

RW

-

1A04:07

SubIndex 007

-

UDINT

RW

-

1A04:08

SubIndex 008

-

UDINT

RW

-

1A04:09

SubIndex 009

-

UDINT

RW

-

1A04:0A

SubIndex 010

-

UDINT

RW

-

1A04:0B

SubIndex 011

-

UDINT

RW

-

1A04:0C

SubIndex 012

-

UDINT

RW

-

1A04:0D

SubIndex 013

-

UDINT

RW

-

1A04:0E

SubIndex 014

-

UDINT

RW

-

1A04:0F

SubIndex 015

-

UDINT

RW

-

1A04:10

SubIndex 016

-

UDINT

RW

-

1A05 DS402 TxPDO-Map Info data 2 Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A05:0

DS402 TxPDO-Map Info data 2 Ch.1

 

USINT

RO

0x1 (1dec)

1A05:01

SubIndex 001

PDO Mapping Entry for “Info data 2”.

UDINT

RW

0x2008:02, 16

1A05:02

SubIndex 002

-

UDINT

RW

-

1A05:03

SubIndex 003

-

UDINT

RW

-

1A05:04

SubIndex 004

-

UDINT

RW

-

1A05:05

SubIndex 005

-

UDINT

RW

-

1A05:06

SubIndex 006

-

UDINT

RW

-

1A05:07

SubIndex 007

-

UDINT

RW

-

1A05:08

SubIndex 008

-

UDINT

RW

-

1A05:09

SubIndex 009

-

UDINT

RW

-

1A05:0A

SubIndex 010

-

UDINT

RW

-

1A05:0B

SubIndex 011

-

UDINT

RW

-

1A05:0C

SubIndex 012

-

UDINT

RW

-

1A05:0D

SubIndex 013

-

UDINT

RW

-

1A05:0E

SubIndex 014

-

UDINT

RW

-

1A05:0F

SubIndex 015

-

UDINT

RW

-

1A05:10

SubIndex 016

-

UDINT

RW

-

1A06 DS402 TxPDO-Map Following error actual value Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A06:0

DS402 TxPDO-Map Following error actual value Ch.1

 

USINT

RO

0x1 (1dec)

1A06:01

SubIndex 001

 

UDINT

RO

0x60f4:00, 32

1A07 DS402 TxPDO-Map Touch probe status Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A07:0

DS402 TxPDO-Map Touch probe status Ch.1

 

USINT

RO

0x1 (1dec)

1A07:01

SubIndex 001

 

UDINT

RO

0x60b9:00, 16

1A08 DS402 TxPDO-Map Touch probe 1 positive edge Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A08:0

DS402 TxPDO-Map Touch probe 1 positive edge Ch.1

 

USINT

RO

0x1 (1dec)

1A08:01

SubIndex 001

 

UDINT

RO

0x60ba:00, 32

1A09 DS402 TxPDO-Map Touch probe 1 negative edge Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A09:0

DS402 TxPDO-Map Touch probe 1 negative edge Ch.1

 

USINT

RO

0x1 (1dec)

1A09:01

SubIndex 001

 

UDINT

RO

0x60bb:00, 32

1A0A DS402 TxPDO-Map Touch probe 2 positive edge Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A0A:0

DS402 TxPDO-Map Touch probe 2 positive edge Ch.1

 

USINT

RO

0x1 (1dec)

1A0A:01

SubIndex 001

 

UDINT

RO

0x60bc:00, 32

1A0B DS402 TxPDO-Map Touch probe 2 negative edge Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A0B:0

DS402 TxPDO-Map Touch probe 2 negative edge Ch.1

 

USINT

RO

0x1 (1dec)

1A0B:01

SubIndex 001

 

UDINT

RO

0x60bd:00, 32

1A0C DS402 TxPDO-Map TxPDO Data Invalid Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A0C:0

DS402 TxPDO-Map TxPDO Data Invalid Ch.1

 

USINT

RO

0x3 (3dec)

1A0C:01

SubIndex 001

 

UDINT

RO

0x0000:00, 1

1A0C:02

SubIndex 002

PDO Mapping Entry for “Position actual value”.

UDINT

RO

0x603e:02, 1

1A0C:03

SubIndex 003

 

UDINT

RO

0x0000:00, 14

1A0D DS402 TxPDO-Map Info data 3 Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A0D:0

DS402 TxPDO-Map Info data 3 Ch.1

 

USINT

RO

0x1 (1dec)

1A0D:01

SubIndex 001

PDO Mapping Entry for “Info data 3”.

UDINT

RW

0x2008:03, 16

1A0D:02

SubIndex 002

-

UDINT

RW

-

1A0D:03

SubIndex 003

-

UDINT

RW

-

1A0D:04

SubIndex 004

-

UDINT

RW

-

1A0D:05

SubIndex 005

-

UDINT

RW

-

1A0D:06

SubIndex 006

-

UDINT

RW

-

1A0D:07

SubIndex 007

-

UDINT

RW

-

1A0D:08

SubIndex 008

-

UDINT

RW

-

1A0D:09

SubIndex 009

-

UDINT

RW

-

1A0D:0A

SubIndex 010

-

UDINT

RW

-

1A0D:0B

SubIndex 011

-

UDINT

RW

-

1A0D:0C

SubIndex 012

-

UDINT

RW

-

1A0D:0D

SubIndex 013

-

UDINT

RW

-

1A0D:0E

SubIndex 014

-

UDINT

RW

-

1A0D:0F

SubIndex 015

-

UDINT

RW

-

1A0D:10

SubIndex 016

-

UDINT

RW

-

1A0E DS402 TxPDO-Map Modes of operation display Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A0E:0

DS402 TxPDO-Map Modes of operation display Ch.1

 

USINT

RO

0x1 (1dec)

1A0E:01

SubIndex 001

 

UDINT

RO

0x6061:00, 8

1A10 DS402 TxPDO-Map Digital Inputs Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A10:0

DS402 TxPDO-Map Digital Inputs Ch.1

 

USINT

RO

0x1 (1dec)

1A10:01

SubIndex 001

 

UDINT

RO

0x60fd:00, 32

1A11 DS402 TxPDO-Map Touch probe time stamp 1 positive value Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A11:0

DS402 TxPDO-Map Touch probe time stamp 1 positive value Ch.1

 

USINT

RO

0x1 (1dec)

1A11:01

SubIndex 001

 

UDINT

RO

0x60d1:00, 32

1A12 DS402 TxPDO-Map Touch probe time stamp 1 negative value Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A12:0

DS402 TxPDO-Map Touch probe time stamp 1 negative value Ch.1

 

USINT

RO

0x1 (1dec)

1A12:01

SubIndex 001

 

UDINT

RO

0x60d2:00, 32

1A13 DS402 TxPDO-Map Touch probe time stamp 2 positive value Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A13:0

DS402 TxPDO-Map Touch probe time stamp 2 positive value Ch.1

 

USINT

RO

0x1 (1dec)

1A13:01

SubIndex 001

 

UDINT

RO

0x60d3:00, 32

1A14 DS402 TxPDO-Map Touch probe time stamp 2 negative value Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A14:0

DS402 TxPDO-Map Touch probe time stamp 2 negative value Ch.1

 

USINT

RO

0x1 (1dec)

1A14:01

SubIndex 001

 

UDINT

RO

0x60d4:00, 32

1A60 DS402 TxPDO-Map Inputs Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A60:0

DS402 TxPDO-Map Inputs Ch.1

 

USINT

RO

0x26 (38dec)

1A60:01

SubIndex 001

 

UDINT

RO

0x0000:00, 1

1A60:02

SubIndex 002

PDO Mapping Entry for “DMC__FeedbackStatus__Latch extern valid”.

UDINT

RO

0x2100:02, 1

1A60:03

SubIndex 003

PDO Mapping Entry for “DMC__FeedbackStatus__Set counter done”.

UDINT

RO

0x2100:03, 1

1A60:04

SubIndex 004

 

UDINT

RO

0x0000:00, 9

1A60:05

SubIndex 005

PDO Mapping Entry for “DMC__FeedbackStatus__Status of extern latch”.

UDINT

RO

0x2100:0d, 1

1A60:06

SubIndex 006

 

UDINT

RO

0x0000:00, 3

1A60:07

SubIndex 007

PDO Mapping Entry for “DMC__DriveStatus__Ready to enable”.

UDINT

RO

0x2100:11, 1

1A60:08

SubIndex 008

PDO Mapping Entry for “DMC__DriveStatus__Ready”.

UDINT

RO

0x2100:12, 1

1A60:09

SubIndex 009

PDO Mapping Entry for “DMC__DriveStatus__Warning”.

UDINT

RO

0x2100:13, 1

1A60:0A

SubIndex 010

PDO Mapping Entry for “DMC__DriveStatus__Error”.

UDINT

RO

0x2100:14, 1

1A60:0B

SubIndex 011

PDO Mapping Entry for “DMC__DriveStatus__Moving positive”.

UDINT

RO

0x2100:15, 1

1A60:0C

SubIndex 012

PDO Mapping Entry for “DMC__DriveStatus__Moving negative”.

UDINT

RO

0x2100:16, 1

1A60:0D

SubIndex 013

 

UDINT

RO

0x0000:00, 5

1A60:0E

SubIndex 014

PDO Mapping Entry for “DMC__DriveStatus__Digital input 1”.

UDINT

RO

0x2100:1c, 1

1A60:0F

SubIndex 015

PDO Mapping Entry for “DMC__DriveStatus__Digital input 2”.

UDINT

RO

0x2100:1d, 1

1A60:10

SubIndex 016

 

UDINT

RO

0x0000:00, 3

1A60:11

SubIndex 017

PDO Mapping Entry for “DMC__PositioningStatus__Busy”.

UDINT

RO

0x2100:21, 1

1A60:12

SubIndex 018

PDO Mapping Entry for “DMC__PositioningStatus__In-Target”.

UDINT

RO

0x2100:22, 1

1A60:13

SubIndex 019

PDO Mapping Entry for “DMC__PositioningStatus__Warning”.

UDINT

RO

0x2100:23, 1

1A60:14

SubIndex 020

PDO Mapping Entry for “DMC__PositioningStatus__Error”.

UDINT

RO

0x2100:24, 1

1A60:15

SubIndex 021

PDO Mapping Entry for “DMC__PositioningStatus__Calibrated”.

UDINT

RO

0x2100:25, 1

1A60:16

SubIndex 022

PDO Mapping Entry for “DMC__PositioningStatus__Accelerate”.

UDINT

RO

0x2100:26, 1

1A60:17

SubIndex 023

PDO Mapping Entry for “DMC__PositioningStatus__Decelerate”.

UDINT

RO

0x2100:27, 1

1A60:18

SubIndex 024

PDO Mapping Entry for “DMC__PositioningStatus__Ready to execute”.

UDINT

RO

0x2100:28, 1

1A60:19

SubIndex 025

 

UDINT

RO

0x0000:00, 8

1A60:1A

SubIndex 026

PDO Mapping Entry for “DMC__Set position”.

UDINT

RO

0x2100:31, 64

1A60:1B

SubIndex 027

PDO Mapping Entry for “DMC__Set velocity”.

UDINT

RO

0x2100:32, 16

1A60:1C

SubIndex 028

PDO Mapping Entry for “DMC__Actual drive time”.

UDINT

RO

0x2100:33, 32

1A60:1D

SubIndex 029

PDO Mapping Entry for “DMC__Actual position lag”.

UDINT

RO

0x2100:34, 64

1A60:1E

SubIndex 030

PDO Mapping Entry for “DMC__Actual velocity”.

UDINT

RO

0x2100:35, 16

1A60:1F

SubIndex 031

PDO Mapping Entry for “DMC__Actual position”.

UDINT

RO

0x2100:36, 64

1A60:20

SubIndex 032

PDO Mapping Entry for “DMC__Error id”.

UDINT

RO

0x2100:37, 32

1A60:21

SubIndex 033

PDO Mapping Entry for “DMC__Input cycle counter”.

UDINT

RO

0x2100:38, 8

1A60:22

SubIndex 034

PDO Mapping Entry for “DMC__Channel id”.

UDINT

RO

0x2100:39, 8

1A60:23

SubIndex 035

PDO Mapping Entry for “DMC__Latch value”.

UDINT

RO

0x2100:3a, 64

1A60:24

SubIndex 036

PDO Mapping Entry for “DMC__Cyclic info data 1”.

UDINT

RO

0x2100:3b, 16

1A60:25

SubIndex 037

PDO Mapping Entry for “DMC__Cyclic info data 2”.

UDINT

RO

0x2100:3c, 16

1A60:26

SubIndex 038

 

UDINT

RO

0x0000:00, 64

1A61 DS402 TxPDO-Map Inputs 32 Bit Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A61:0

DS402 TxPDO-Map Inputs 32 Bit Ch.1

 

USINT

RO

0x2A (42dec)

1A61:01

SubIndex 001

 

UDINT

RO

0x0000:00, 1

1A61:02

SubIndex 002

PDO Mapping Entry for “DMC__FeedbackStatus__Latch extern valid”.

UDINT

RO

0x2100:02, 1

1A61:03

SubIndex 003

PDO Mapping Entry for “DMC__FeedbackStatus__Set counter done”.

UDINT

RO

0x2100:03, 1

1A61:04

SubIndex 004

 

UDINT

RO

0x0000:00, 9

1A61:05

SubIndex 005

PDO Mapping Entry for “DMC__FeedbackStatus__Status of extern latch”.

UDINT

RO

0x2100:0d, 1

1A61:06

SubIndex 006

 

UDINT

RO

0x0000:00, 3

1A61:07

SubIndex 007

PDO Mapping Entry for “DMC__DriveStatus__Ready to enable”.

UDINT

RO

0x2100:11, 1

1A61:08

SubIndex 008

PDO Mapping Entry for “DMC__DriveStatus__Ready”.

UDINT

RO

0x2100:12, 1

1A61:09

SubIndex 009

PDO Mapping Entry for “DMC__DriveStatus__Warning”.

UDINT

RO

0x2100:13, 1

1A61:0A

SubIndex 010

PDO Mapping Entry for “DMC__DriveStatus__Error”.

UDINT

RO

0x2100:14, 1

1A61:0B

SubIndex 011

PDO Mapping Entry for “DMC__DriveStatus__Moving positive”.

UDINT

RO

0x2100:15, 1

1A61:0C

SubIndex 012

PDO Mapping Entry for “DMC__DriveStatus__Moving negative”.

UDINT

RO

0x2100:16, 1

1A61:0D

SubIndex 013

 

UDINT

RO

0x0000:00, 5

1A61:0E

SubIndex 014

PDO Mapping Entry for “DMC__DriveStatus__Digital input 1”.

UDINT

RO

0x2100:1c, 1

1A61:0F

SubIndex 015

PDO Mapping Entry for “DMC__DriveStatus__Digital input 2”.

UDINT

RO

0x2100:1d, 1

1A61:10

SubIndex 016

 

UDINT

RO

0x0000:00, 3

1A61:11

SubIndex 017

PDO Mapping Entry for “DMC__PositioningStatus__Busy”.

UDINT

RO

0x2100:21, 1

1A61:12

SubIndex 018

PDO Mapping Entry for “DMC__PositioningStatus__In-Target”.

UDINT

RO

0x2100:22, 1

1A61:13

SubIndex 019

PDO Mapping Entry for “DMC__PositioningStatus__Warning”.

UDINT

RO

0x2100:23, 1

1A61:14

SubIndex 020

PDO Mapping Entry for “DMC__PositioningStatus__Error”.

UDINT

RO

0x2100:24, 1

1A61:15

SubIndex 021

PDO Mapping Entry for “DMC__PositioningStatus__Calibrated”.

UDINT

RO

0x2100:25, 1

1A61:16

SubIndex 022

PDO Mapping Entry for “DMC__PositioningStatus__Accelerate”.

UDINT

RO

0x2100:26, 1

1A61:17

SubIndex 023

PDO Mapping Entry for “DMC__PositioningStatus__Decelerate”.

UDINT

RO

0x2100:27, 1

1A61:18

SubIndex 024

PDO Mapping Entry for “DMC__PositioningStatus__Ready to execute”.

UDINT

RO

0x2100:28, 1

1A61:19

SubIndex 025

 

UDINT

RO

0x0000:00, 8

1A61:1A

SubIndex 026

PDO Mapping Entry for “DMC__Set position”.

UDINT

RO

0x2100:31, 32

1A61:1B

SubIndex 027

 

UDINT

RO

0x0000:00, 32

1A61:1C

SubIndex 028

PDO Mapping Entry for “DMC__Set velocity”.

UDINT

RO

0x2100:32, 16

1A61:1D

SubIndex 029

PDO Mapping Entry for “DMC__Actual drive time”.

UDINT

RO

0x2100:33, 32

1A61:1E

SubIndex 030

PDO Mapping Entry for “DMC__Actual position lag”.

UDINT

RO

0x2100:34, 32

1A61:1F

SubIndex 031

 

UDINT

RO

0x0000:00, 32

1A61:20

SubIndex 032

PDO Mapping Entry for “DMC__Actual velocity”.

UDINT

RO

0x2100:35, 16

1A61:21

SubIndex 033

PDO Mapping Entry for “DMC__Actual position”.

UDINT

RO

0x2100:36, 32

1A61:22

SubIndex 034

 

UDINT

RO

0x0000:00, 32

1A61:23

SubIndex 035

PDO Mapping Entry for “DMC__Error id”.

UDINT

RO

0x2100:37, 32

1A61:24

SubIndex 036

PDO Mapping Entry for “DMC__Input cycle counter”.

UDINT

RO

0x2100:38, 8

1A61:25

SubIndex 037

PDO Mapping Entry for “DMC__Channel id”.

UDINT

RO

0x2100:39, 8

1A61:26

SubIndex 038

PDO Mapping Entry for “DMC__Latch value”.

UDINT

RO

0x2100:3a, 32

1A61:27

SubIndex 039

 

UDINT

RO

0x0000:00, 32

1A61:28

SubIndex 040

PDO Mapping Entry for “DMC__Cyclic info data 1”.

UDINT

RO

0x2100:3b, 16

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A61:29

SubIndex 041

PDO Mapping Entry for “DMC__Cyclic info data 2”.

UDINT

RO

0x2100:3c, 16

1A61:2A

SubIndex 042

 

UDINT

RO

0x0000:00, 64

1A70 DS402 TxPDO-Map Dynamic Inputs Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A70:0

DS402 TxPDO-Map Dynamic Inputs Ch.1

 

USINT

RO

0x1 (1dec)

1A70:01

SubIndex 001

PDO Mapping Entry for “Dyninput cycle counter”.

UDINT

RW

0x2008:04, 8

1A70:02

SubIndex 002

-

UDINT

RW

-

1A70:03

SubIndex 003

-

UDINT

RW

-

…

…

…

…

…

…

1A70:FD

SubIndex 253

-

UDINT

RW

-

1A70:FE

SubIndex 254

-

UDINT

RW

-

1A70:FF

SubIndex 255

-

UDINT

RW

-

1A80 DS402 TxPDO-Map Position actual value Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A80:0

DS402 TxPDO-Map Position actual value Ch.2

 

USINT

RO

0x1 (1dec)

1A80:01

SubIndex 001

 

UDINT

RO

0x6864:00, 32

1A81 DS402 TxPDO-Map Statusword Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A81:0

DS402 TxPDO-Map Statusword Ch.2

 

USINT

RO

0x1 (1dec)

1A81:01

SubIndex 001

 

UDINT

RO

0x6841:00, 16

1A82 DS402 TxPDO-Map Velocity actual value Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A82:0

DS402 TxPDO-Map Velocity actual value Ch.2

 

USINT

RO

0x1 (1dec)

1A82:01

SubIndex 001

 

UDINT

RO

0x686c:00, 32

1A83 DS402 TxPDO-Map Torque actual value Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A83:0

DS402 TxPDO-Map Torque actual value Ch.2

 

USINT

RO

0x1 (1dec)

1A83:01

SubIndex 001

 

UDINT

RO

0x6877:00, 16

1A84 DS402 TxPDO-Map Info data 1 Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A84:0

DS402 TxPDO-Map Info data 1 Ch.2

 

USINT

RO

0x1 (1dec)

1A84:01

SubIndex 001

PDO Mapping Entry for “Info data 1”.

UDINT

RW

0x2808:01, 16

1A84:02

SubIndex 002

-

UDINT

RW

-

1A84:03

SubIndex 003

-

UDINT

RW

-

1A84:04

SubIndex 004

-

UDINT

RW

-

1A84:05

SubIndex 005

-

UDINT

RW

-

1A84:06

SubIndex 006

-

UDINT

RW

-

1A84:07

SubIndex 007

-

UDINT

RW

-

1A84:08

SubIndex 008

-

UDINT

RW

-

1A84:09

SubIndex 009

-

UDINT

RW

-

1A84:0A

SubIndex 010

-

UDINT

RW

-

1A84:0B

SubIndex 011

-

UDINT

RW

-

1A84:0C

SubIndex 012

-

UDINT

RW

-

1A84:0D

SubIndex 013

-

UDINT

RW

-

1A84:0E

SubIndex 014

-

UDINT

RW

-

1A84:0F

SubIndex 015

-

UDINT

RW

-

1A84:10

SubIndex 016

-

UDINT

RW

-

1A85 DS402 TxPDO-Map Info data 2 Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A85:0

DS402 TxPDO-Map Info data 2 Ch.2

 

USINT

RO

0x1 (1dec)

1A85:01

SubIndex 001

PDO Mapping Entry for “Info data 2”.

UDINT

RW

0x2808:02, 16

1A85:02

SubIndex 002

-

UDINT

RW

-

1A85:03

SubIndex 003

-

UDINT

RW

-

1A85:04

SubIndex 004

-

UDINT

RW

-

1A85:05

SubIndex 005

-

UDINT

RW

-

1A85:06

SubIndex 006

-

UDINT

RW

-

1A85:07

SubIndex 007

-

UDINT

RW

-

1A85:08

SubIndex 008

-

UDINT

RW

-

1A85:09

SubIndex 009

-

UDINT

RW

-

1A85:0A

SubIndex 010

-

UDINT

RW

-

1A85:0B

SubIndex 011

-

UDINT

RW

-

1A85:0C

SubIndex 012

-

UDINT

RW

-

1A85:0D

SubIndex 013

-

UDINT

RW

-

1A85:0E

SubIndex 014

-

UDINT

RW

-

1A85:0F

SubIndex 015

-

UDINT

RW

-

1A85:10

SubIndex 016

-

UDINT

RW

-

1A86 DS402 TxPDO-Map Following error actual value Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A86:0

DS402 TxPDO-Map Following error actual value Ch.2

 

USINT

RO

0x1 (1dec)

1A86:01

SubIndex 001

 

UDINT

RO

0x68f4:00, 32

1A87 DS402 TxPDO-Map Touch probe status Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A87:0

DS402 TxPDO-Map Touch probe status Ch.2

 

USINT

RO

0x1 (1dec)

1A87:01

SubIndex 001

 

UDINT

RO

0x68b9:00, 16

1A88 DS402 TxPDO-Map Touch probe 1 positive edge Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A88:0

DS402 TxPDO-Map Touch probe 1 positive edge Ch.2

 

USINT

RO

0x1 (1dec)

1A88:01

SubIndex 001

 

UDINT

RO

0x68ba:00, 32

1A89 DS402 TxPDO-Map Touch probe 1 negative edge Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A89:0

DS402 TxPDO-Map Touch probe 1 negative edge Ch.2

 

USINT

RO

0x1 (1dec)

1A89:01

SubIndex 001

 

UDINT

RO

0x68bb:00, 32

1A8A DS402 TxPDO-Map Touch probe 2 positive edge Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A8A:0

DS402 TxPDO-Map Touch probe 2 positive edge Ch.2

 

USINT

RO

0x1 (1dec)

1A8A:01

SubIndex 001

 

UDINT

RO

0x68bc:00, 32

1A8B DS402 TxPDO-Map Touch probe 2 negative edge Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A8B:0

DS402 TxPDO-Map Touch probe 2 negative edge Ch.2

 

USINT

RO

0x1 (1dec)

1A8B:01

SubIndex 001

 

UDINT

RO

0x68bd:00, 32

1A8C DS402 TxPDO-Map TxPDO Data Invalid Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A8C:0

DS402 TxPDO-Map TxPDO Data Invalid Ch.2

 

USINT

RO

0x3 (3dec)

1A8C:01

SubIndex 001

 

UDINT

RO

0x0000:00, 1

1A8C:02

SubIndex 002

PDO Mapping Entry for “Position actual value”.

UDINT

RO

0x683e:02, 1

1A8C:03

SubIndex 003

 

UDINT

RO

0x0000:00, 14

1A8D DS402 TxPDO-Map Info data 3 Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A8D:0

DS402 TxPDO-Map Info data 3 Ch.2

 

USINT

RO

0x1 (1dec)

1A8D:01

SubIndex 001

PDO Mapping Entry for “Info data 3”.

UDINT

RW

0x2808:03, 16

1A8D:02

SubIndex 002

-

UDINT

RW

-

1A8D:03

SubIndex 003

-

UDINT

RW

-

1A8D:04

SubIndex 004

-

UDINT

RW

-

1A8D:05

SubIndex 005

-

UDINT

RW

-

1A8D:06

SubIndex 006

-

UDINT

RW

-

1A8D:07

SubIndex 007

-

UDINT

RW

-

1A8D:08

SubIndex 008

-

UDINT

RW

-

1A8D:09

SubIndex 009

-

UDINT

RW

-

1A8D:0A

SubIndex 010

-

UDINT

RW

-

1A8D:0B

SubIndex 011

-

UDINT

RW

-

1A8D:0C

SubIndex 012

-

UDINT

RW

-

1A8D:0D

SubIndex 013

-

UDINT

RW

-

1A8D:0E

SubIndex 014

-

UDINT

RW

-

1A8D:0F

SubIndex 015

-

UDINT

RW

-

1A8D:10

SubIndex 016

-

UDINT

RW

-

1A8E DS402 TxPDO-Map Modes of operation display Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A8E:0

DS402 TxPDO-Map Modes of operation display Ch.2

 

USINT

RO

0x1 (1dec)

1A8E:01

SubIndex 001

 

UDINT

RO

0x6861:00, 8

1A90 DS402 TxPDO-Map Digital Inputs Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A90:0

DS402 TxPDO-Map Digital Inputs Ch.2

 

USINT

RO

0x1 (1dec)

1A90:01

SubIndex 001

 

UDINT

RO

0x68fd:00, 32

1A91 DS402 TxPDO-Map Touch probe time stamp 1 positive value Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A91:0

DS402 TxPDO-Map Touch probe time stamp 1 positive value Ch.2

 

USINT

RO

0x1 (1dec)

1A91:01

SubIndex 001

 

UDINT

RO

0x68d1:00, 32

1A92 DS402 TxPDO-Map Touch probe time stamp 1 negative value Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A92:0

DS402 TxPDO-Map Touch probe time stamp 1 negative value Ch.2

 

USINT

RO

0x1 (1dec)

1A92:01

SubIndex 001

 

UDINT

RO

0x68d2:00, 32

1A93 DS402 TxPDO-Map Touch probe time stamp 2 positive value Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A93:0

DS402 TxPDO-Map Touch probe time stamp 2 positive value Ch.2

 

USINT

RO

0x1 (1dec)

1A93:01

SubIndex 001

 

UDINT

RO

0x68d3:00, 32

1A94 DS402 TxPDO-Map Touch probe time stamp 2 negative value Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1A94:0

DS402 TxPDO-Map Touch probe time stamp 2 negative value Ch.2

 

USINT

RO

0x1 (1dec)

1A94:01

SubIndex 001

 

UDINT

RO

0x68d4:00, 32

1AE0 DS402 TxPDO-Map Inputs Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1AE0:0

DS402 TxPDO-Map Inputs Ch.2

 

USINT

RO

0x26 (38dec)

1AE0:01

SubIndex 001

 

UDINT

RO

0x0000:00, 1

1AE0:02

SubIndex 002

PDO Mapping Entry for “DMC__FeedbackStatus__Latch extern valid”.

UDINT

RO

0x2900:02, 1

1AE0:03

SubIndex 003

PDO Mapping Entry for “DMC__FeedbackStatus__Set counter done”.

UDINT

RO

0x2900:03, 1

1AE0:04

SubIndex 004

 

UDINT

RO

0x0000:00, 9

1AE0:05

SubIndex 005

PDO Mapping Entry for “DMC__FeedbackStatus__Status of extern latch”.

UDINT

RO

0x2900:0d, 1

1AE0:06

SubIndex 006

 

UDINT

RO

0x0000:00, 3

1AE0:07

SubIndex 007

PDO Mapping Entry for “DMC__DriveStatus__Ready to enable”.

UDINT

RO

0x2900:11, 1

1AE0:08

SubIndex 008

PDO Mapping Entry for “DMC__DriveStatus__Ready”.

UDINT

RO

0x2900:12, 1

1AE0:09

SubIndex 009

PDO Mapping Entry for “DMC__DriveStatus__Warning”.

UDINT

RO

0x2900:13, 1

1AE0:0A

SubIndex 010

PDO Mapping Entry for “DMC__DriveStatus__Error”.

UDINT

RO

0x2900:14, 1

1AE0:0B

SubIndex 011

PDO Mapping Entry for “DMC__DriveStatus__Moving positive”.

UDINT

RO

0x2900:15, 1

1AE0:0C

SubIndex 012

PDO Mapping Entry for “DMC__DriveStatus__Moving negative”.

UDINT

RO

0x2900:16, 1

1AE0:0D

SubIndex 013

 

UDINT

RO

0x0000:00, 5

1AE0:0E

SubIndex 014

PDO Mapping Entry for “DMC__DriveStatus__Digital input 1”.

UDINT

RO

0x2900:1c, 1

1AE0:0F

SubIndex 015

PDO Mapping Entry for “DMC__DriveStatus__Digital input 2”.

UDINT

RO

0x2900:1d, 1

1AE0:10

SubIndex 016

 

UDINT

RO

0x0000:00, 3

1AE0:11

SubIndex 017

PDO Mapping Entry for “DMC__PositioningStatus__Busy”.

UDINT

RO

0x2900:21, 1

1AE0:12

SubIndex 018

PDO Mapping Entry for “DMC__PositioningStatus__In-Target”.

UDINT

RO

0x2900:22, 1

1AE0:13

SubIndex 019

PDO Mapping Entry for “DMC__PositioningStatus__Warning”.

UDINT

RO

0x2900:23, 1

1AE0:14

SubIndex 020

PDO Mapping Entry for “DMC__PositioningStatus__Error”.

UDINT

RO

0x2900:24, 1

1AE0:15

SubIndex 021

PDO Mapping Entry for “DMC__PositioningStatus__Calibrated”.

UDINT

RO

0x2900:25, 1

1AE0:16

SubIndex 022

PDO Mapping Entry for “DMC__PositioningStatus__Accelerate”.

UDINT

RO

0x2900:26, 1

1AE0:17

SubIndex 023

PDO Mapping Entry for “DMC__PositioningStatus__Decelerate”.

UDINT

RO

0x2900:27, 1

1AE0:18

SubIndex 024

PDO Mapping Entry for “DMC__PositioningStatus__Ready to execute”.

UDINT

RO

0x2900:28, 1

1AE0:19

SubIndex 025

 

UDINT

RO

0x0000:00, 8

1AE0:1A

SubIndex 026

PDO Mapping Entry for “DMC__Set position”.

UDINT

RO

0x2900:31, 64

1AE0:1B

SubIndex 027

PDO Mapping Entry for “DMC__Set velocity”.

UDINT

RO

0x2900:32, 16

1AE0:1C

SubIndex 028

PDO Mapping Entry for “DMC__Actual drive time”.

UDINT

RO

0x2900:33, 32

1AE0:1D

SubIndex 029

PDO Mapping Entry for “DMC__Actual position lag”.

UDINT

RO

0x2900:34, 64

1AE0:1E

SubIndex 030

PDO Mapping Entry for “DMC__Actual velocity”.

UDINT

RO

0x2900:35, 16

1AE0:1F

SubIndex 031

PDO Mapping Entry for “DMC__Actual position”.

UDINT

RO

0x2900:36, 64

1AE0:20

SubIndex 032

PDO Mapping Entry for “DMC__Error id”.

UDINT

RO

0x2900:37, 32

1AE0:21

SubIndex 033

PDO Mapping Entry for “DMC__Input cycle counter”.

UDINT

RO

0x2900:38, 8

1AE0:22

SubIndex 034

PDO Mapping Entry for “DMC__Channel id”.

UDINT

RO

0x2900:39, 8

1AE0:23

SubIndex 035

PDO Mapping Entry for “DMC__Latch value”.

UDINT

RO

0x2900:3a, 64

1AE0:24

SubIndex 036

PDO Mapping Entry for “DMC__Cyclic info data 1”.

UDINT

RO

0x2900:3b, 16

1AE0:25

SubIndex 037

PDO Mapping Entry for “DMC__Cyclic info data 2”.

UDINT

RO

0x2900:3c, 16

1AE0:26

SubIndex 038

 

UDINT

RO

0x0000:00, 64

1AE1 DS402 TxPDO-Map Inputs 32 Bit Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1AE1:0

DS402 TxPDO-Map Inputs 32 Bit Ch.2

 

USINT

RO

0x2A (42dec)

1AE1:01

SubIndex 001

 

UDINT

RO

0x0000:00, 1

1AE1:02

SubIndex 002

PDO Mapping Entry for “DMC__FeedbackStatus__Latch extern valid”.

UDINT

RO

0x2900:02, 1

1AE1:03

SubIndex 003

PDO Mapping Entry for “DMC__FeedbackStatus__Set counter done”.

UDINT

RO

0x2900:03, 1

1AE1:04

SubIndex 004

 

UDINT

RO

0x0000:00, 9

1AE1:05

SubIndex 005

PDO Mapping Entry for “DMC__FeedbackStatus__Status of extern latch”.

UDINT

RO

0x2900:0d, 1

1AE1:06

SubIndex 006

 

UDINT

RO

0x0000:00, 3

1AE1:07

SubIndex 007

PDO Mapping Entry for “DMC__DriveStatus__Ready to enable”.

UDINT

RO

0x2900:11, 1

1AE1:08

SubIndex 008

PDO Mapping Entry for “DMC__DriveStatus__Ready”.

UDINT

RO

0x2900:12, 1

1AE1:09

SubIndex 009

PDO Mapping Entry for “DMC__DriveStatus__Warning”.

UDINT

RO

0x2900:13, 1

1AE1:0A

SubIndex 010

PDO Mapping Entry for “DMC__DriveStatus__Error”.

UDINT

RO

0x2900:14, 1

1AE1:0B

SubIndex 011

PDO Mapping Entry for “DMC__DriveStatus__Moving positive”.

UDINT

RO

0x2900:15, 1

1AE1:0C

SubIndex 012

PDO Mapping Entry for “DMC__DriveStatus__Moving negative”.

UDINT

RO

0x2900:16, 1

1AE1:0D

SubIndex 013

 

UDINT

RO

0x0000:00, 5

1AE1:0E

SubIndex 014

PDO Mapping Entry for “DMC__DriveStatus__Digital input 1”.

UDINT

RO

0x2900:1c, 1

1AE1:0F

SubIndex 015

PDO Mapping Entry for “DMC__DriveStatus__Digital input 2”.

UDINT

RO

0x2900:1d, 1

1AE1:10

SubIndex 016

 

UDINT

RO

0x0000:00, 3

1AE1:11

SubIndex 017

PDO Mapping Entry for “DMC__PositioningStatus__Busy”.

UDINT

RO

0x2900:21, 1

1AE1:12

SubIndex 018

PDO Mapping Entry for “DMC__PositioningStatus__In-Target”.

UDINT

RO

0x2900:22, 1

1AE1:13

SubIndex 019

PDO Mapping Entry for “DMC__PositioningStatus__Warning”.

UDINT

RO

0x2900:23, 1

1AE1:14

SubIndex 020

PDO Mapping Entry for “DMC__PositioningStatus__Error”.

UDINT

RO

0x2900:24, 1

1AE1:15

SubIndex 021

PDO Mapping Entry for “DMC__PositioningStatus__Calibrated”.

UDINT

RO

0x2900:25, 1

1AE1:16

SubIndex 022

PDO Mapping Entry for “DMC__PositioningStatus__Accelerate”.

UDINT

RO

0x2900:26, 1

1AE1:17

SubIndex 023

PDO Mapping Entry for “DMC__PositioningStatus__Decelerate”.

UDINT

RO

0x2900:27, 1

1AE1:18

SubIndex 024

PDO Mapping Entry for “DMC__PositioningStatus__Ready to execute”.

UDINT

RO

0x2900:28, 1

1AE1:19

SubIndex 025

 

UDINT

RO

0x0000:00, 8

1AE1:1A

SubIndex 026

PDO Mapping Entry for “DMC__Set position”.

UDINT

RO

0x2900:31, 32

1AE1:1B

SubIndex 027

 

UDINT

RO

0x0000:00, 32

1AE1:1C

SubIndex 028

PDO Mapping Entry for “DMC__Set velocity”.

UDINT

RO

0x2900:32, 16

1AE1:1D

SubIndex 029

PDO Mapping Entry for “DMC__Actual drive time”.

UDINT

RO

0x2900:33, 32

1AE1:1E

SubIndex 030

PDO Mapping Entry for “DMC__Actual position lag”.

UDINT

RO

0x2900:34, 32

1AE1:1F

SubIndex 031

 

UDINT

RO

0x0000:00, 32

1AE1:20

SubIndex 032

PDO Mapping Entry for “DMC__Actual velocity”.

UDINT

RO

0x2900:35, 16

1AE1:21

SubIndex 033

PDO Mapping Entry for “DMC__Actual position”.

UDINT

RO

0x2900:36, 32

1AE1:22

SubIndex 034

 

UDINT

RO

0x0000:00, 32

1AE1:23

SubIndex 035

PDO Mapping Entry for “DMC__Error id”.

UDINT

RO

0x2900:37, 32

1AE1:24

SubIndex 036

PDO Mapping Entry for “DMC__Input cycle counter”.

UDINT

RO

0x2900:38, 8

1AE1:25

SubIndex 037

PDO Mapping Entry for “DMC__Channel id”.

UDINT

RO

0x2900:39, 8

1AE1:26

SubIndex 038

PDO Mapping Entry for “DMC__Latch value”.

UDINT

RO

0x2900:3a, 32

1AE1:27

SubIndex 039

 

UDINT

RO

0x0000:00, 32

1AE1:28

SubIndex 040

PDO Mapping Entry for “DMC__Cyclic info data 1”.

UDINT

RO

0x2900:3b, 16

Index (hex)

Name

Meaning

Data Type

Flags

Default

1AE1:29

SubIndex 041

PDO Mapping Entry for “DMC__Cyclic info data 2”.

UDINT

RO

0x2900:3c, 16

1AE1:2A

SubIndex 042

 

UDINT

RO

0x0000:00, 64

1AF0 DS402 TxPDO-Map Dynamic Inputs Ch.2

Index (hex)

Name

Meaning

Data Type

Flags

Default

1AF0:0

DS402 TxPDO-Map Dynamic Inputs Ch.2

 

USINT

RO

0x1 (1dec)

1AF0:01

SubIndex 001

PDO Mapping Entry for “Dyninput cycle counter”.

UDINT

RW

0x2808:04, 8

1AF0:02

SubIndex 002

-

UDINT

RW

-

1AF0:03

SubIndex 003

-

UDINT

RW

-

…

…

…

…

…

…

1AF0:FD

SubIndex 253

-

UDINT

RW

-

1AF0:FE

SubIndex 254

-

UDINT

RW

-

1AF0:FF

SubIndex 255

-

UDINT

RW

-

1C00 Sync manager type

Index (hex)

Name

Meaning

Data Type

Flags

Default

1C00:0

Sync manager type

 

USINT

RO

0x6 (6dec)

1C00:01

SubIndex 001

 

USINT

RO

0x1 (1dec)

1C00:02

SubIndex 002

 

USINT

RO

0x2 (2dec)

1C00:03

SubIndex 003

 

USINT

RO

0x3 (3dec)

1C00:04

SubIndex 004

 

USINT

RO

0x4 (4dec)

1C00:05

SubIndex 005

 

USINT

RO

0x5 (5dec)

1C00:06

SubIndex 006

 

USINT

RO

0x6 (6dec)

1C12 RxPDO assign

Index (hex)

Name

Meaning

Data Type

Flags

Default

1C12:0

RxPDO assign

 

USINT

RO

0x4 (4dec)

1C12:01

SubIndex 001

 

UINT

RW

0x16 (22dec)

1C12:02

SubIndex 002

 

UINT

RW

0x616 (1558dec)

1C12:03

SubIndex 003

 

UINT

RW

0x8016 (32790dec)

1C12:04

SubIndex 004

 

UINT

RW

0x8616 (34326dec)

1C12:05

SubIndex 005

 

UINT

RW

0x0 (0dec)

1C12:06

SubIndex 006

 

UINT

RW

0x0 (0dec)

1C12:07

SubIndex 007

 

UINT

RW

0x0 (0dec)

1C12:08

SubIndex 008

 

UINT

RW

0x0 (0dec)

1C12:09

SubIndex 009

 

UINT

RW

0x0 (0dec)

1C12:0A

SubIndex 010

 

UINT

RW

0x0 (0dec)

1C12:0B

SubIndex 011

 

UINT

RW

0x0 (0dec)

1C12:0C

SubIndex 012

 

UINT

RW

0x0 (0dec)

1C12:0D

SubIndex 013

 

UINT

RW

0x0 (0dec)

1C12:0E

SubIndex 014

 

UINT

RW

0x0 (0dec)

1C12:0F

SubIndex 015

 

UINT

RW

0x0 (0dec)

1C12:10

SubIndex 016

 

UINT

RW

0x0 (0dec)

1C12:11

SubIndex 017

 

UINT

RW

0x0 (0dec)

1C12:12

SubIndex 018

 

UINT

RW

0x0 (0dec)

1C12:13

SubIndex 019

 

UINT

RW

0x0 (0dec)

1C12:14

SubIndex 020

 

UINT

RW

0x0 (0dec)

1C12:15

SubIndex 021

 

UINT

RW

0x0 (0dec)

1C12:16

SubIndex 022

 

UINT

RW

0x0 (0dec)

1C12:17

SubIndex 023

 

UINT

RW

0x0 (0dec)

1C12:18

SubIndex 024

 

UINT

RW

0x0 (0dec)

1C12:19

SubIndex 025

 

UINT

RW

0x0 (0dec)

1C12:1A

SubIndex 026

 

UINT

RW

0x0 (0dec)

1C12:1B

SubIndex 027

 

UINT

RW

0x0 (0dec)

1C12:1C

SubIndex 028

 

UINT

RW

0x0 (0dec)

1C13 TxPDO assign

Index (hex)

Name

Meaning

Data Type

Flags

Default

1C13:0

TxPDO assign

 

USINT

RO

0x6 (6dec)

1C13:01

SubIndex 001

 

UINT

RW

0x1A (26dec)

1C13:02

SubIndex 002

 

UINT

RW

0x11A (282dec)

1C13:03

SubIndex 003

 

UINT

RW

0x61A (1562dec)

1C13:04

SubIndex 004

 

UINT

RW

0x801A (32794dec)

1C13:05

SubIndex 005

 

UINT

RW

0x811A (33050dec)

1C13:06

SubIndex 006

 

UINT

RW

0x861A (34330dec)

1C13:07

SubIndex 007

 

UINT

RW

0x0 (0dec)

1C13:08

SubIndex 008

 

UINT

RW

0x0 (0dec)

1C13:09

SubIndex 009

 

UINT

RW

0x0 (0dec)

1C13:0A

SubIndex 010

 

UINT

RW

0x0 (0dec)

1C13:0B

SubIndex 011

 

UINT

RW

0x0 (0dec)

1C13:0C

SubIndex 012

 

UINT

RW

0x0 (0dec)

1C13:0D

SubIndex 013

 

UINT

RW

0x0 (0dec)

1C13:0E

SubIndex 014

 

UINT

RW

0x0 (0dec)

1C13:0F

SubIndex 015

 

UINT

RW

0x0 (0dec)

1C13:10

SubIndex 016

 

UINT

RW

0x0 (0dec)

1C13:11

SubIndex 017

 

UINT

RW

0x0 (0dec)

1C13:12

SubIndex 018

 

UINT

RW

0x0 (0dec)

1C13:13

SubIndex 019

 

UINT

RW

0x0 (0dec)

1C13:14

SubIndex 020

 

UINT

RW

0x0 (0dec)

1C13:15

SubIndex 021

 

UINT

RW

0x0 (0dec)

1C13:16

SubIndex 022

 

UINT

RW

0x0 (0dec)

1C13:17

SubIndex 023

 

UINT

RW

0x0 (0dec)

1C13:18

SubIndex 024

 

UINT

RW

0x0 (0dec)

1C13:19

SubIndex 025

 

UINT

RW

0x0 (0dec)

1C13:1A

SubIndex 026

 

UINT

RW

0x0 (0dec)

1C13:1B

SubIndex 027

 

UINT

RW

0x0 (0dec)

1C13:1C

SubIndex 028

 

UINT

RW

0x0 (0dec)

1C13:1D

SubIndex 029

 

UINT

RW

0x0 (0dec)

1C13:1E

SubIndex 030

 

UINT

RW

0x0 (0dec)

1C13:1F

SubIndex 031

 

UINT

RW

0x0 (0dec)

1C13:20

SubIndex 032

 

UINT

RW

0x0 (0dec)

1C13:21

SubIndex 033

 

UINT

RW

0x0 (0dec)

1C13:22

SubIndex 034

 

UINT

RW

0x0 (0dec)

1C13:23

SubIndex 035

 

UINT

RW

0x0 (0dec)

1C13:24

SubIndex 036

 

UINT

RW

0x0 (0dec)

1C13:25

SubIndex 037

 

UINT

RW

0x0 (0dec)

1C13:26

SubIndex 038

 

UINT

RW

0x0 (0dec)

1C13:27

SubIndex 039

 

UINT

RW

0x0 (0dec)

1C13:28

SubIndex 040

 

UINT

RW

0x0 (0dec)

1C13:29

SubIndex 041

 

UINT

RW

0x0 (0dec)

1C13:2A

SubIndex 042

 

UINT

RW

0x0 (0dec)

1C14 Dynamic RxPDO assign

Index (hex)

Name

Meaning

Data Type

Flags

Default

1C14:0

Dynamic RxPDO assign

-

USINT

RO

-

1C14:01

SubIndex 001

 

UINT

RW

0x0 (0dec)

1C14:02

SubIndex 002

 

UINT

RW

0x0 (0dec)

1C15 Dynamic TxPDO assign

Index (hex)

Name

Meaning

Data Type

Flags

Default

1C15:0

Dynamic TxPDO assign

-

USINT

RO

-

1C15:01

SubIndex 001

 

UINT

RW

0x0 (0dec)

1C15:02

SubIndex 002

 

UINT

RW

0x0 (0dec)

1C32 SM output parameter

Index (hex)

Name

Meaning

Data Type

Flags

Default

1C32:0

SM output parameter

 

USINT

RO

0x20 (32dec)

1C32:01

Sync mode

 

UINT

RW

0x3 (3dec)

1C32:02

Cycle time

 

UDINT

RW

0xF4240 (1000000dec)

1C32:03

Shift time

 

UDINT

RO

0x0 (0dec)

1C32:04

Sync modes supported

 

UINT

RO

0x812 (2066dec)

1C32:05

Minimum cycle time

 

UDINT

RO

0x1E848 (125000dec)

1C32:06

Calc and copy time

 

UDINT

RO

0x7530 (30000dec)

1C32:07

Minimum delay time

 

UDINT

RO

0x7A12 (31250dec)

1C32:08

Get Cycle Time

 

UINT

RW

0x0 (0dec)

1C32:09

Maximum delay time

 

UDINT

RO

0x7A12 (31250dec)

1C32:0A

Sync0 Cycle Time

 

UDINT

RO

0xF424 (62500dec)

1C32:0B

SM event missed counter

-

UINT

RO

-

1C32:0C

Cycle exceeded counter

-

UINT

RO

-

1C32:0D

Shift too short counter

-

UINT

RO

-

1C32:20

Sync error

-

BOOL

RO

-

1C33 SM input parameter

Index (hex)

Name

Meaning

Data Type

Flags

Default

1C33:0

SM input parameter

 

USINT

RO

0x20 (32dec)

1C33:01

Sync mode

 

UINT

RW

0x3 (3dec)

1C33:02

Cycle time

 

UDINT

RW

0xF4240 (1000000dec)

1C33:03

Shift time

 

UDINT

RO

0x0 (0dec)

1C33:04

Sync modes supported

 

UINT

RO

0x12 (18dec)

1C33:05

Minimum cycle time

 

UDINT

RO

0x1E848 (125000dec)

1C33:06

Calc and copy time

 

UDINT

RO

0x7530 (30000dec)

1C33:07

Minimum delay time

 

UDINT

RO

0x0 (0dec)

1C33:08

Get Cycle Time

 

UINT

RW

0x0 (0dec)

1C33:09

Maximum delay time

 

UDINT

RO

0x7A12 (31250dec)

1C33:0A

Sync0 Cycle Time

 

UDINT

RO

0xF424 (62500dec)

1C33:0B

SM event missed counter

-

UINT

RO

-

1C33:0C

Cycle exceeded counter

-

UINT

RO

-

1C33:0D

Shift too short counter

-

UINT

RO

-

1C33:20

Sync error

-

BOOL

RO

-

F008 Code word

Index (hex)

Name

Meaning

Data Type

Flags

Default

F008:0

Code word

-

UDINT

RO

-

F081 Download revision

Index (hex)

Name

Meaning

Data Type

Flags

Default

F081:0

Download revision

 

USINT

RO

0x1 (1dec)

F081:01

Revision number

-

UDINT

RW

-

FB00 Command

Index (hex)

Name

Meaning

Data Type

Flags

Default

FB00:0

Command

 

USINT

RO

0x3 (3dec)

FB00:01

Request

-

ARRAY [0..1] OF BYTE

RW

-

FB00:02

Status

-

USINT

RO

-

FB00:03

Response

-

ARRAY [0..5] OF BYTE

RO

-

FB13 DRV Key code

Index (hex)

Name

Meaning

Data Type

Flags

Default

FB13:0

DRV Key code

 

USINT

RO

0x1 (1dec)

FB13:01

Code

-

ARRAY [0..31] OF BYTE

RW

-

FB40 Memory interface

Index (hex)

Name

Meaning

Data Type

Flags

Default

FB40:0

Memory interface

 

USINT

RO

0x3 (3dec)

FB40:01

Address

-

UDINT

RW

-

FB40:02

Length

-

UINT

RW

-

FB40:03

Data

-

ARRAY [0..7] OF BYTE

RW

-