Configuration data
Index 2002 Amplifier Settings
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
2002:0 | Amplifier Settings | Maximum subindex | UINT8 | RO | 0x49 (73dec) |
2002:11 | Device type | 1: Servo drive (cannot be changed) | UINT32 | RW | 0x00000001 (1dec) |
2002:12* | Current loop integral time | Integral component of current controller | UINT16 | RW | 0x000A (10dec) |
2002:13* | Current loop proportional gain | Proportional component of current controller | UINT16 | RW | 0x0064 (100dec) |
2002:14 | Velocity loop integral time | Integral component of velocity controller | UINT32 | RW | 0x00000032 (50dec) |
2002:15 | Velocity loop proportional gain | Proportional component of velocity controller | UINT32 | RW | 0x00000096 (150dec) |
2002:17 | Position loop proportional gain | Proportional component position controller | UINT32 | RW | 0x0000000A (10dec) |
2002:19 | Nominal DC link voltage | Nominal DC link voltage | UINT32 | RW | 0x0000BB80 (48000dec) |
2002:1A | Min DC link voltage | Minimum DC link voltage | UINT32 | RW | 0x00001A90 (6800dec) |
2002:1B | Max DC link voltage | Maximum DC link voltage | UINT32 | RW | 0x0000EA60 (60000dec) |
2002:29 | Amplifier I2T warn level | I²T model warning threshold | UINT8 | RW | 0x50 (80dec) |
2002:2A | Amplifier I2T error level | I²T model error threshold | UINT8 | RW | 0x69 (105dec) |
2002:2B | Amplifier temperature warn level | Overtemperature warning threshold | UINT16 | RW | 0x0320 (800dec) |
2002:2C | Amplifier temperature error level | Overtemperature error threshold | UINT16 | RW | 0x03E8 (1000dec) |
2002:31 | Velocity limitation | Velocity limitation | UINT32 | RW | 0x00040000 (262144dec) |
2002:32 | Short circuit brake duration max | Max. duration of armature short circuit brake | UINT16 | RW | 0x03E8 (1000dec) |
2002:33 | Stand still window | Standstill window | UINT16 | RW | 0x0000 (0dec) |
2002:41 | Low-pass filter frequency | Low-pass filter frequency | UINT16 | RW | 0x0140 (320dec) |
2002:49 | Halt ramp deceleration | Halt ramp deceleration | UINT32 | RW | 0x0000F570 (62832dec) |
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
2002:53 | Position loop proportional gain | Proportional component position controller | UINT32 | RW | 0x00000000 (0 dec) |
2002:54 | Feature bits | The adjustable motor current values can be interpreted as peak values or rms values. The feature bit (2002:54) enables the conversion. Peak value → Bit 0 = 0 (default) normal output current → Bit 1 = 0 (default) From these, the following combinations can be set: 0dec → normal output current interpreted as peak value 1dec → normal output current interpreted as rms value 2dec → increased output current interpreted as peak value 3dec → increased output current interpreted as rms value | UINT32 | RW | 0x00000000 (0 dec) |
2002:55 | Select info data 1 | Selection "Info data 1" | UINT8 | RW | 0x00 (0 dec) |
Torque current (filtered 1ms) [1000th of rated current] | |||||
DC link voltage [mV] | |||||
PCB temperature [0.1 °C] | |||||
Errors: | |||||
Warnings: Bit2: Undervoltage | |||||
I2T Motor [%] | |||||
I2T Amplifier [%] | |||||
Input Level: Bit0: Digital Input 1 Level | |||||
Feature Bits: Bit0: Referenced (Parameter 2010:02) | |||||
2002:56 | Select info data 2 | Selection "Info data 2" | UINT8 | RW | 0x00 (0 dec) |
Torque current (filtered 1ms) [1000th of rated current] | |||||
DC link voltage [mV] | |||||
PCB temperature [0.1 °C] | |||||
Errors: | |||||
Warnings: Bit2: Undervoltage | |||||
I2T Motor [%] | |||||
I2T Amplifier [%] | |||||
Input Level: Bit0: Digital Input 1 Level | |||||
Feature Bits: Bit0: Referenced (Parameter 2010:02) |
*) see index 2059 FB OCT Nameplate
Index 2003 Motor Settings
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
2003:0 | Motor Settings | Maximum subindex | UINT8 | RO | 0x2D (45dec) |
2003:11* | Max current | Peak current The adjustable motor current values can be interpreted as peak values or rms values. The feature bit (2002:54) enables the conversion. Peak value → Bit 0 = 0 (default) RMS value → Bit 0 = 1 | UINT32 | RW | 0x00001770 (6000dec) |
2003:13* | Motor pole pairs | Number of pole pairs | UINT8 | RW | 0x03 (3dec) |
2003:15* | Commutation offset | Commutation offset (between electrical zero position and mechanical single-turn zero position) | INT16 | RW | 0x0000 (0dec) |
2003:16* | Torque constant | Torque constant | UINT32 | RW | 0x00000000 (0dec) |
2003:18* | Rotor moment of inertia | Mass moment of inertia of the motor | UINT32 | RW | 0x00000000 (0dec) |
2003:19* | Winding inductance | Inductance | UINT16 | RW | 0x000E (14dec) |
2003:29 | Motor I2T warn level | I2T model warning threshold | UINT8 | RW | 0x50 (80dec) |
2003:2A | Motor I2T error level | I2T model error threshold | UINT8 | RW | 0x69 (105dec) |
2003:2B* | Motor Temperature warn level | Overtemperature warning threshold | UINT16 | RW | 0x0000 (0dec) |
2003:2C* | Motor Temperature error level | Overtemperature error threshold | UINT16 | RW | 0x0000 (0dec) |
2003:2D* | Motor thermal time constant | Thermal time constant | UINT16 | RW | 0x0028 (40dec) |
*) see index 2059 FB OCT Nameplate
Index 2004 brake settings
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
2004:0 | Brake settings | Maximum subindex | UINT8 | RO | 0x14 (20dec) |
2004:01 | Manual override (release) | Manual release of the motor holding brake | BOOLEAN | RW | 0x00 (0dec) |
2004:11* | Release delay | Time required by the holding brake for opening (releasing) after the voltage was applied | UINT16 | RW | 0x0000 (0dec) |
2004:12* | Application delay | Time required by the holding brake for closing (holding) after the voltage was switched off | UINT16 | RW | 0x0000 (0dec) |
2004:13 | Emergency application timeout | Time that the amplifier waits until the speed has reached the standstill window after the stop request (set speed 0 after halt ramp or Torque off). The holding brake is triggered irrespective of the speed if the set waiting time is exceeded. With suspended axes and the Torque off setting for the error case, this parameter must be set to a very short time in order to prevent further sagging of the axis/load. | UINT16 | RW | 0x0000 (0dec) |
2004:14* | Brake moment of inertia | Mass moment of inertia of the brake | UINT16 | RW | 0x0000 (0dec) |
*) see index 2059 FB OCT Nameplate
Index 2010 feedback settings
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
2010:0 | Feedback settings | Maximum subindex | UINT8 | RO | 0x13 (19dec) |
2010:01 | Invert feedback direction | Inverting the count direction | BOOLEAN | RW | 0x00 (0dec) |
2010:02 | Referenced | The box sets this parameter to FALSE in two cases:
If you want to use this function, set the parameter to TRUE and monitor it. The value of this parameter is retained if the power supply is interrupted. | BOOLEAN | RW | 0x00 (0dec) |
2010:11 | Device type | 3: OCT (not changeable) | UINT32 | RW | 0x00000003 (3dec) |
2010:12 | Singleturn bits | Number of single-turn bits | UINT8 | RW | 0x14 (20dec) |
2010:13 | Multi-turn bits | Number of multi-turn bits | UINT8 | RW | 0x0C (12dec) |
2010:14 | Observer bandwidth | Bandwidth of the speed observer [Hz] | UINT16 | RW | 0x01F4 (500dec) |
2010:15 | Observer feed-forward | Load ratio [%] 50% = mass moments of inertia of input and output are equal | UINT8 | RW | 0x01 (0dec) |
2010:17 | Position Offset |
| UINT32 | RW | 0x00000000 (0dec) |
Index 2018 OCT Settings
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
2018:0 | OCT Settings | Maximum subindex | UINT8 | RO | 0x03 (3dec) |
2018:01 | Enable auto config | Configuration takes place automatically after the reading of the electronic identification plate | BOOLEAN | RW | 0x00 (0dec) |
2018:02 | Reconfig identical motor | When replacing identical motors, reconfiguration takes place automatically after reading the electronic identification plate. Enable autoconfig must be activated. | BOOLEAN | RW | 0x00 (0dec) |
2018:03 | Reconfig non-identical motor | When replacing non-identical motors, reconfiguration takes place automatically after reading the electronic identification plate. Enable autoconfig must be activated. | BOOLEAN | RW | 0x00 (0dec) |