Standard objects

Index 1000 Device type

Index (hex)

Name

Meaning

Data type

Flags

Default

1000:0

Device type

Device type of the EtherCAT slave: the Lo-Word contains the used CoE profile (5001). The Hi-Word contains the module profile according to the modular device profile.

UINT32

RO

0x00001389 (5001dec)

Index 1008 Device name

Index (hex)

Name

Meaning

Data type

Flags

Default

1008:0

Device name

Device name of the EtherCAT slave

STRING

RO

EP3751-0260

Index 1009 Hardware version

Index (hex)

Name

Meaning

Data type

Flags

Default

1009:0

Hardware version

Hardware version of the EtherCAT slave

STRING

RO

 

Index 100A Software version

Index (hex)

Name

Meaning

Data type

Flags

Default

100A:0

Software version

Firmware version of the EtherCAT slave

STRING

RO

01

Index 100B Bootloader version

Index (hex)

Name

Meaning

Data type

Flags

Default

100B:0

Bootloader version

 

STRING

RO

N/A

Index 1011 Restore default parameters

Index (hex)

Name

Meaning

Data type

Flags

Default

1011:0

Restore default parameters

Restore default parameters

UINT8

RO

0x01 (1dec)

1011:01

SubIndex 001

If this object is set to "0x64616F6C" in the set value dialog, all backup objects are reset to their delivery state.

UINT32

RW

0x00000000 (0dec)

Index 1018 Identity

Index (hex)

Name

Meaning

Data type

Flags

Default

1018:0

Identity

Information for identifying the slave

UINT8

RO

0x04 (4dec)

1018:01

Vendor ID

Vendor ID of the EtherCAT slave

UINT32

RO

0x00000002 (2dec)

1018:02

Product code

Product code of the EtherCAT slave

UINT32

RO

0x0EA74052 (245842002dec)

1018:03

Revision

Revision number of the EtherCAT slave; the Low Word (bit 0-15) indicates the special terminal number, the High Word (bit 16-31) refers to the device description

UINT32

RO

0x00000000 (0dec)

1018:04

Serial number

Serial number of the EtherCAT slave; the Low Byte (bit 0-7) of the Low Word contains the year of production, the High Byte (bit 8-15) of the Low Word contains the week of production, the High Word (bit 16-31) is 0

UINT32

RO

0x00000000 (0dec)

Index 10E2 Manufacturer-specific Identification Code

Index (hex)

Name

Meaning

Data type

Flags

Default

10E2:0

Manufacturer-specific Identification Code

 

UINT8

RO

0x01 (1dec)

10E2:01

SubIndex 001

 

STRING

RO

 

Index 10F0 Backup parameter handling

Index (hex)

Name

Meaning

Data type

Flags

Default

10F0:01

Checksum

Checksum across all backup entries of the EtherCAT slave

UINT32

RO

0x00000000 (0dec)

Index 1660 DIG RxPDO-Map

Index (hex)

Name

Meaning

Data type

Flags

Default

1660:0

DIG RxPDO-Map

PDO Mapping RxPDO 97

UINT8

RO

0x04 (4dec)

1660:01

SubIndex 001

1. PDO Mapping entry (2 bits align)

UINT32

RO

0x7070:01, 1

1660:02

SubIndex 002

2. PDO Mapping entry (object 0x7070 (AI Acc Outputs), entry 0x03 (Start self test))

UINT32

RO

0x7070:02, 1

1660:03

SubIndex 003

3. PDO Mapping entry (object 0x7070 (AI Acc Outputs), entry 0x04 (Tare))

UINT32

RO

0x7070:03, 1

1660:04

SubIndex 004

4. PDO Mapping entry (13 bits align)

UINT32

RO

0x0000:00, 13

Index 18C0 AI Sensor Temperature TxPDO-Par (Real)

Index (hex)

Name

Meaning

Data type

Flags

Default

18C0:0

AI Sensor Temperature TxPDO-Par (Real)

PDO parameter TxPDO 193

UINT8

RO

0x06 (6dec)

18C0:06

Exclude TxPDOs

Specifies the TxPDOs (index of TxPDO mapping objects) that must not be transferred together with TxPDO 193

OCTET-STRING[2]

RO

C1 1A

Index 18C1 AI Sensor Temperature TxPDO-Par Int

Index (hex)

Name

Meaning

Data type

Flags

Default

18C1:0

AI Sensor Temperature TxPDO-Par Int

PDO parameter TxPDO 194

UINT8

RO

0x06 (6dec)

18C1:06

Exclude TxPDOs

Specifies the TxPDOs (index of TxPDO mapping objects) that must not be transferred together with TxPDO 194

OCTET-STRING[2]

RO

C0 1A

Index 1A00 AI Acc X TxPDO-Map Status

Index (hex)

Name

Meaning

Data type

Flags

Default

1A00:01

SubIndex 001

1. PDO Mapping entry (8 bits align)

UINT32

RO

0x0000:00, 8

1A00:02

SubIndex 002

2. PDO Mapping entry (object 0x6000 (AI Acc Inputs X), entry 0x09 (Self test status))

UINT32

RO

0x6000:09, 2

1A00:03

SubIndex 003

3. PDO Mapping entry (object 0x6000 (AI Acc Inputs X), entry 0x0B (Slope detected))

UINT32

RO

0x6000:0B, 1

1A00:04

SubIndex 004

4. PDO Mapping entry (3 bits align)

UINT32

RO

0x0000:00, 2

1A00:05

SubIndex 005

5. PDO Mapping entry (object 0x6000 (AI Acc Inputs), entry 0x0F (TxPDO State))

UINT32

RO

0x6000:0E, 1

1A00:06

SubIndex 006

6. PDO Mapping entry (object 0x6000 (AI Acc Inputs), entry 0x10 (TxPDO Toggle))

UINT32

RO

0x6000:0F, 1

1A00:07

SubIndex 007

7. PDO Mapping entry (16 bits align)

UINT32

RO

0x6000:10, 1

1A00:08

SubIndex 008

8. PDO Mapping entry (16 bits align)

UINT32

RO

0x0000:00, 16

Index 1A00 AI Acc X TxPDO-Map Status

Index (hex)

Name

Meaning

Data type

Flags

Default

1A00:0

AI Acc X TxPDO-Map Status

PDO Mapping TxPDO 1

UINT8

RO

0x08 (8dec)

1A00:01

SubIndex 001

1. PDO Mapping entry (8 bits align)

UINT32

RO

0x0000:00, 8

1A00:02

SubIndex 002

2. PDO Mapping entry (object 0x6000 (AI Acc Inputs), entry 0x09 (Self test status))

UINT32

RO

0x6000:09, 2

1A00:03

SubIndex 003

3. PDO Mapping entry (object 0x6000 (AI Acc Inputs), entry 0x0B (Slope detected))

UINT32

RO

0x6000:0B, 1

1A00:04

SubIndex 004

4. PDO Mapping entry (3 bits align)

UINT32

RO

0x0000:00, 2

1A00:05

SubIndex 005

5. PDO Mapping entry (object 0x6000 (AI Acc Inputs), entry 0x0F (TxPDO State))

UINT32

RO

0x6000:0E, 1

1A00:06

SubIndex 006

6. PDO Mapping entry (object 0x6000 (AI Acc Inputs), entry 0x10 (TxPDO Toggle))

UINT32

RO

0x6000:0F, 1

1A00:07

SubIndex 007

7. PDO Mapping entry (16 bits align)

UINT32

RO

0x6000:10, 1

1A00:08

SubIndex 008

8. PDO Mapping entry (16 bits align)

UINT32

RO

0x0000:00, 16

Index 1A01 AI Acc X TxPDO-Map Input Cycle Counter

Index (hex)

Name

Meaning

Data type

Flags

Default

1A01:0

AI Acc X TxPDO-Map Input Cycle Counter

PDO Mapping TxPDO 2

UINT8

RO

0x01 (1dec)

1A01:01

SubIndex 001

1. PDO Mapping entry (8 bits align)

UINT32

RO

0x6000:14, 16

Index 1A03 AI Acc X TxPDO-Map Input Legacy Int

Index (hex)

Name

Meaning

Data type

Flags

Default

1A03:0

AI Acc X TxPDO-Map Input Legacy Int

PDO Mapping TxPDO 4

UINT8

RO

0x09 (9dec)

1A03:01

SubIndex 001

1. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x01 (Sample))

UINT32

RO

0x0000:00, 8

1A03:02

SubIndex 002

2. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x02 (Sample))

UINT32

RO

0x6000:09, 2

1A03:03

SubIndex 003

3. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x03 (Sample))

UINT32

RO

0x6000:0B, 1

1A03:04

SubIndex 004

4. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x04 (Sample))

UINT32

RO

0x0000:00, 2

1A03:05

SubIndex 005

5. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x05 (Sample))

UINT32

RO

0x6000:0E, 1

1A03:06

SubIndex 006

6. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x06 (Sample))

UINT32

RO

0x6000:0F, 1

1A03:07

SubIndex 007

7. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x07 (Sample))

UINT32

RO

0x6000:10, 1

1A03:08

SubIndex 008

8. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x08 (Sample))

UINT32

RO

0x0000:00, 16

1A03:09

SubIndex 009

9. PDO Mapping entry (object 0x6000 (AI Acc Inputs), entry 0x12 (Value))

UINT32

RO

0x6000:12, 32

Index 1A04 AI Acc X TxPDO-Map Samples 1 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A04:0

AI Acc X TxPDO-Map Samples 1 (Real32)

PDO Mapping TxPDO 5

UINT8

RO

0x01 (1dec)

1A04:01

SubIndex 001

1. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6003:01, 32

Index 1A05 AI Acc X TxPDO-Map Samples 1

Index (hex)

Name

Meaning

Data type

Flags

Default

1A05:0

AI Acc X TxPDO-Map Samples 1

PDO Mapping TxPDO 6

UINT8

RO

0x01 (1dec)

1A05:01

SubIndex 001

1. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x01 (Sample))

UINT32

RO

0x6001:01, 32

Index 1A06 AI Acc X TxPDO-Map Samples 2 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A06:0

AI Acc X TxPDO-Map Samples 2 (Real32)

PDO Mapping TxPDO 7

UINT8

RO

0x02 (2dec)

1A06:01

SubIndex 001

1. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6003:01, 32

1A06:02

SubIndex 002

2. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6003:02, 32

Index 1A07 AI Acc X TxPDO-Map Samples 2

Index (hex)

Name

Meaning

Data type

Flags

Default

1A07:0

AI Acc X TxPDO-Map Samples 2

PDO Mapping TxPDO 8

UINT8

RO

0x02 (2dec)

1A07:01

SubIndex 001

1. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x01 (Sample))

UINT32

RO

0x6001:01, 32

1A07:02

SubIndex 002

2. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x02 (Sample))

UINT32

RO

0x6001:02, 32

Index 1A08 AI Acc X TxPDO-Map Samples 4 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A08:0

AI Acc X TxPDO-Map Samples 4 (Real32)

PDO Mapping TxPDO 9

UINT8

RO

0x04 (4dec)

1A08:01

SubIndex 001

1. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6003:01, 32

1A08:02

SubIndex 002

2. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6003:02, 32

1A08:03

SubIndex 003

3. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6003:03, 32

1A08:04

SubIndex 004

4. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6003:04, 32

Index 1A09 AI Acc X TxPDO-Map Samples 4

Index (hex)

Name

Meaning

Data type

Flags

Default

1A09:0

AI Acc X TxPDO-Map Samples 4

PDO Mapping TxPDO 10

UINT8

RO

0x04 (4dec)

1A09:01

SubIndex 001

1. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x01 (Sample))

UINT32

RO

0x6001:01, 32

1A09:02

SubIndex 002

2. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x02 (Sample))

UINT32

RO

0x6001:02, 32

1A09:03

SubIndex 003

3. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x03 (Sample))

UINT32

RO

0x6001:03, 32

1A09:04

SubIndex 004

4. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x04 (Sample))

UINT32

RO

0x6001:04, 32

Index 1A0A AI Acc X TxPDO-Map Samples 8 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A0A:0

AI Acc X TxPDO-Map Samples 8 (Real32)

PDO Mapping TxPDO 11

UINT8

RO

0x08 (8dec)

1A0A:01

SubIndex 001

1. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6003:01, 32

1A0A:02

SubIndex 002

2. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6003:02, 32

1A0A:03

SubIndex 003

3. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6003:03, 32

1A0A:04

SubIndex 004

4. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6003:04, 32

1A0A:05

SubIndex 005

5. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x05 (Sample))

UINT32

RO

0x6003:05, 32

1A0A:06

SubIndex 006

6. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x06 (Sample))

UINT32

RO

0x6003:06, 32

1A0A:07

SubIndex 007

7. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x07 (Sample))

UINT32

RO

0x6003:07, 32

1A0A:08

SubIndex 008

8. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x08 (Sample))

UINT32

RO

0x6003:08, 32

Index 1A0B AI Acc X TxPDO-Map Samples 8

Index (hex)

Name

Meaning

Data type

Flags

Default

1A0B:0

AI Acc X TxPDO-Map Samples 8

PDO Mapping TxPDO 12

UINT8

RO

0x08 (8dec)

1A0B:01

SubIndex 001

1. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x01 (Sample))

UINT32

RO

0x6001:01, 32

1A0B:02

SubIndex 002

2. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x02 (Sample))

UINT32

RO

0x6001:02, 32

1A0B:03

SubIndex 003

3. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x03 (Sample))

UINT32

RO

0x6001:03, 32

1A0B:04

SubIndex 004

4. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x04 (Sample))

UINT32

RO

0x6001:04, 32

1A0B:05

SubIndex 005

5. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x05 (Sample))

UINT32

RO

0x6001:05, 32

1A0B:06

SubIndex 006

6. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x06 (Sample))

UINT32

RO

0x6001:06, 32

1A0B:07

SubIndex 007

7. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x07 (Sample))

UINT32

RO

0x6001:07, 32

1A0B:08

SubIndex 008

8. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x08 (Sample))

UINT32

RO

0x6001:08, 32

Index 1A0C AI Acc X TxPDO-Map Samples 10 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A0C:0

AI Acc X TxPDO-Map Samples 10 (Real32)

PDO Mapping TxPDO 13

UINT8

RO

0x0A (10dec)

1A0C:01

SubIndex 001

1. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6003:01, 32

1A0C:02

SubIndex 002

2. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6003:02, 32

1A0C:03

SubIndex 003

3. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6003:03, 32

1A0C:04

SubIndex 004

4. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6003:04, 32

1A0C:05

SubIndex 005

5. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x05 (Sample))

UINT32

RO

0x6003:05, 32

1A0C:06

SubIndex 006

6. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x06 (Sample))

UINT32

RO

0x6003:06, 32

1A0C:07

SubIndex 007

7. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x07 (Sample))

UINT32

RO

0x6003:07, 32

1A0C:08

SubIndex 008

8. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x08 (Sample))

UINT32

RO

0x6003:08, 32

1A0C:09

SubIndex 009

9. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x09 (Sample))

UINT32

RO

0x6003:09, 32

1A0C:0A

SubIndex 010

10. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x0A (Sample))

UINT32

RO

0x6003:0A, 32

Index 1A0D AI Acc X TxPDO-Map Samples 10

Index (hex)

Name

Meaning

Data type

Flags

Default

1A0D:0

AI Acc X TxPDO-Map Samples 10

PDO Mapping TxPDO 14

UINT8

RO

0x0A (10dec)

1A0D:01

SubIndex 001

1. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x01 (Sample))

UINT32

RO

0x6001:01, 32

1A0D:02

SubIndex 002

2. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x02 (Sample))

UINT32

RO

0x6001:02, 32

1A0D:03

SubIndex 003

3. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x03 (Sample))

UINT32

RO

0x6001:03, 32

1A0D:04

SubIndex 004

4. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x04 (Sample))

UINT32

RO

0x6001:04, 32

1A0D:05

SubIndex 005

5. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x05 (Sample))

UINT32

RO

0x6001:05, 32

1A0D:06

SubIndex 006

6. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x06 (Sample))

UINT32

RO

0x6001:06, 32

1A0D:07

SubIndex 007

7. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x07 (Sample))

UINT32

RO

0x6001:07, 32

1A0D:08

SubIndex 008

8. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x08 (Sample))

UINT32

RO

0x6001:08, 32

1A0D:09

SubIndex 009

9. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x09 (Sample))

UINT32

RO

0x6001:09, 32

1A0D:0A

SubIndex 010

10. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x0A (Sample))

UINT32

RO

0x6001:0A, 32

Index 1A0E AI Acc X TxPDO-Map Samples 16 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A0E:0

AI Acc X TxPDO-Map Samples 16 (Real32)

PDO Mapping TxPDO 15

UINT8

RO

0x10 (16dec)

1A0E:01

SubIndex 001

1. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6003:01, 32

1A0E:02

SubIndex 002

2. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6003:02, 32

1A0E:03

SubIndex 003

3. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6003:03, 32

1A0E:04

SubIndex 004

4. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6003:04, 32

1A0E:05

SubIndex 005

5. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x05 (Sample))

UINT32

RO

0x6003:05, 32

1A0E:06

SubIndex 006

6. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x06 (Sample))

UINT32

RO

0x6003:06, 32

1A0E:07

SubIndex 007

7. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x07 (Sample))

UINT32

RO

0x6003:07, 32

1A0E:08

SubIndex 008

8. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x08 (Sample))

UINT32

RO

0x6003:08, 32

1A0E:09

SubIndex 009

9. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x09 (Sample))

UINT32

RO

0x6003:09, 32

1A0E:0A

SubIndex 010

10. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x0A (Sample))

UINT32

RO

0x6003:0A, 32

1A0E:0B

SubIndex 011

11. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x0B (Sample))

UINT32

RO

0x6003:0B, 32

1A0E:0C

SubIndex 012

12. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x0C (Sample))

UINT32

RO

0x6003:0C, 32

1A0E:0D

SubIndex 013

13. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x0D (Sample))

UINT32

RO

0x6003:0D, 32

1A0E:0E

SubIndex 014

14. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x0E (Sample))

UINT32

RO

0x6003:0E, 32

1A0E:0F

SubIndex 015

15. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x0F (Sample))

UINT32

RO

0x6003:0F, 32

1A0E:10

SubIndex 016

16. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x10 (Sample))

UINT32

RO

0x6003:10, 32

Index 1A0F AI Acc X TxPDO-Map Samples 16

Index (hex)

Name

Meaning

Data type

Flags

Default

1A0F:0

AI Acc X TxPDO-Map Samples 16

PDO Mapping TxPDO 16

UINT8

RO

0x10 (16dec)

1A0F:01

SubIndex 001

1. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x01 (Sample))

UINT32

RO

0x6001:01, 32

1A0F:02

SubIndex 002

2. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x02 (Sample))

UINT32

RO

0x6001:02, 32

1A0F:03

SubIndex 003

3. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x03 (Sample))

UINT32

RO

0x6001:03, 32

1A0F:04

SubIndex 004

4. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x04 (Sample))

UINT32

RO

0x6001:04, 32

1A0F:05

SubIndex 005

5. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x05 (Sample))

UINT32

RO

0x6001:05, 32

1A0F:06

SubIndex 006

6. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x06 (Sample))

UINT32

RO

0x6001:06, 32

1A0F:07

SubIndex 007

7. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x07 (Sample))

UINT32

RO

0x6001:07, 32

1A0F:08

SubIndex 008

8. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x08 (Sample))

UINT32

RO

0x6001:08, 32

1A0F:09

SubIndex 009

9. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x09 (Sample))

UINT32

RO

0x6001:09, 32

1A0F:0A

SubIndex 010

10. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x0A (Sample))

UINT32

RO

0x6001:0A, 32

1A0F:0B

SubIndex 011

11. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x0B (Sample))

UINT32

RO

0x6001:0B, 32

1A0F:0C

SubIndex 012

12. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x0C (Sample))

UINT32

RO

0x6001:0C, 32

1A0F:0D

SubIndex 013

13. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x0D (Sample))

UINT32

RO

0x6001:0D, 32

1A0F:0E

SubIndex 014

14. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x0E (Sample))

UINT32

RO

0x6001:0E, 32

1A0F:0F

SubIndex 015

15. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x0F (Sample))

UINT32

RO

0x6001:0F, 32

1A0F:10

SubIndex 016

16. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x10 (Sample))

UINT32

RO

0x6001:10, 32

Index 1A10 AI Acc X TxPDO-Map Samples 20 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A10:0

AI Acc X TxPDO-Map Samples 20 (Real32)

PDO Mapping TxPDO 17

UINT8

RO

0x14 (20dec)

1A10:01

SubIndex 001

1. PDO Mapping entry (8 bits align)

UINT32

RO

0x6003:01, 32

1A10:02

SubIndex 002

2. PDO Mapping entry (object 0x6010 (AI Acc Inputs), entry 0x09 (Self test status))

UINT32

RO

0x6003:02, 32

1A10:03

SubIndex 003

3. PDO Mapping entry (object 0x6010 (AI Acc Inputs), entry 0x0B (Slope detected))

UINT32

RO

0x6003:03, 32

1A10:04

SubIndex 004

4. PDO Mapping entry (3 bits align)

UINT32

RO

0x6003:04, 32

1A10:05

SubIndex 005

5. PDO Mapping entry (object 0x6010 (AI Acc Inputs), entry 0x0F (TxPDO State))

UINT32

RO

0x6003:05, 32

1A10:06

SubIndex 006

6. PDO Mapping entry (object 0x6010 (AI Acc Inputs), entry 0x10 (TxPDO Toggle))

UINT32

RO

0x6003:06, 32

1A10:07

SubIndex 007

7. PDO Mapping entry (16 bits align)

UINT32

RO

0x6003:07, 32

1A10:08

SubIndex 008

8. PDO Mapping entry (object 0x6010 (AI Acc Inputs), entry 0x13 (Value (Real32)))

UINT32

RO

0x6003:08, 32

1A10:09

SubIndex 009

9. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x09 (Sample))

UINT32

RO

0x6003:09, 32

1A10:0A

SubIndex 010

10. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x0A (Sample))

UINT32

RO

0x6003:0A, 32

1A10:0B

SubIndex 011

11. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x0B (Sample))

UINT32

RO

0x6003:0B, 32

1A10:0C

SubIndex 012

12. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x0C (Sample))

UINT32

RO

0x6003:0C, 32

1A10:0D

SubIndex 013

13. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x0D (Sample))

UINT32

RO

0x6003:0D, 32

1A10:0E

SubIndex 014

14. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x0E (Sample))

UINT32

RO

0x6003:0E, 32

1A10:0F

SubIndex 015

15. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x0F (Sample))

UINT32

RO

0x6003:0F, 32

1A10:10

SubIndex 016

16. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x10 (Sample))

UINT32

RO

0x6003:10, 32

1A10:11

SubIndex 017

17. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x11 (Sample))

UINT32

RO

0x6003:11, 32

1A10:12

SubIndex 018

18. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x12 (Sample))

UINT32

RO

0x6003:12, 32

1A10:13

SubIndex 019

19. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x13 (Sample))

UINT32

RO

0x6003:13, 32

1A10:14

SubIndex 020

20. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x14 (Sample))

UINT32

RO

0x6003:14, 32

Index 1A11 AI Acc X TxPDO-Map Samples 20

Index (hex)

Name

Meaning

Data type

Flags

Default

1A11:0

AI Acc X TxPDO-Map Samples 20

PDO Mapping TxPDO 18

UINT8

RO

0x14 (20dec)

1A11:01

SubIndex 001

1. PDO Mapping entry (8 bits align)

UINT32

RO

0x6001:01, 32

1A11:02

SubIndex 002

2. PDO Mapping entry (object 0x6010 (AI Acc Inputs), entry 0x09 (Self test status))

UINT32

RO

0x6001:02, 32

1A11:03

SubIndex 003

3. PDO Mapping entry (object 0x6010 (AI Acc Inputs), entry 0x0B (Slope detected))

UINT32

RO

0x6001:03, 32

1A11:04

SubIndex 004

4. PDO Mapping entry (3 bits align)

UINT32

RO

0x6001:04, 32

1A11:05

SubIndex 005

5. PDO Mapping entry (object 0x6010 (AI Acc Inputs), entry 0x0F (TxPDO State))

UINT32

RO

0x6001:05, 32

1A11:06

SubIndex 006

6. PDO Mapping entry (object 0x6010 (AI Acc Inputs), entry 0x10 (TxPDO Toggle))

UINT32

RO

0x6001:06, 32

1A11:07

SubIndex 007

7. PDO Mapping entry (16 bits align)

UINT32

RO

0x6001:07, 32

1A11:08

SubIndex 008

8. PDO Mapping entry (object 0x6010 (AI Acc Inputs), entry 0x12 (Value))

UINT32

RO

0x6001:08, 32

1A11:09

SubIndex 009

9. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x09 (Sample))

UINT32

RO

0x6001:09, 32

1A11:0A

SubIndex 010

10. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x0A (Sample))

UINT32

RO

0x6001:0A, 32

1A11:0B

SubIndex 011

11. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x0B (Sample))

UINT32

RO

0x6001:0B, 32

1A11:0C

SubIndex 012

12. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x0C (Sample))

UINT32

RO

0x6001:0C, 32

1A11:0D

SubIndex 013

13. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x0D (Sample))

UINT32

RO

0x6001:0D, 32

1A11:0E

SubIndex 014

14. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x0E (Sample))

UINT32

RO

0x6001:0E, 32

1A11:0F

SubIndex 015

15. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x0F (Sample))

UINT32

RO

0x6001:0F, 32

1A11:10

SubIndex 016

16. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x10 (Sample))

UINT32

RO

0x6001:10, 32

1A11:11

SubIndex 017

17. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x11 (Sample))

UINT32

RO

0x6001:11, 32

1A11:12

SubIndex 018

18. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x12 (Sample))

UINT32

RO

0x6001:12, 32

1A11:13

SubIndex 019

19. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x13 (Sample))

UINT32

RO

0x6001:13, 32

1A11:14

SubIndex 020

20. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x14 (Sample))

UINT32

RO

0x6001:14, 32

Index 1A12 AI Acc X TxPDO-Map Samples 40 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A12:0

AI Acc X TxPDO-Map Samples 40 (Real32)

PDO Mapping TxPDO 19

UINT8

RO

0x28 (40dec)

1A12:01

SubIndex 001

1. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6003:01, 32

1A12:02

SubIndex 002

2. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6003:02, 32

1A12:03

SubIndex 003

3. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6003:03, 32

1A12:04

SubIndex 004

4. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6003:04, 32

1A12:05

SubIndex 005

5. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x05 (Sample))

UINT32

RO

0x6003:05, 32

1A12:06

SubIndex 006

6. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x06 (Sample))

UINT32

RO

0x6003:06, 32

1A12:07

SubIndex 007

7. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x07 (Sample))

UINT32

RO

0x6003:07, 32

1A12:08

SubIndex 008

8. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x08 (Sample))

UINT32

RO

0x6003:08, 32

1A12:09

SubIndex 009

9. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x09 (Sample))

UINT32

RO

0x6003:09, 32

1A12:0A

SubIndex 010

10. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x0A (Sample))

UINT32

RO

0x6003:0A, 32

1A12:0B

SubIndex 011

11. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x0B (Sample))

UINT32

RO

0x6003:0B, 32

1A12:0C

SubIndex 012

12. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x0C (Sample))

UINT32

RO

0x6003:0C, 32

1A12:0D

SubIndex 013

13. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x0D (Sample))

UINT32

RO

0x6003:0D, 32

1A12:0E

SubIndex 014

14. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x0E (Sample))

UINT32

RO

0x6003:0E, 32

1A12:0F

SubIndex 015

15. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x0F (Sample))

UINT32

RO

0x6003:0F, 32

1A12:10

SubIndex 016

16. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x10 (Sample))

UINT32

RO

0x6003:10, 32

1A12:11

SubIndex 017

17. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x11 (Sample))

UINT32

RO

0x6003:11, 32

1A12:12

SubIndex 018

18. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x12 (Sample))

UINT32

RO

0x6003:12, 32

1A12:13

SubIndex 019

19. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x13 (Sample))

UINT32

RO

0x6003:13, 32

1A12:14

SubIndex 020

20. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x14 (Sample))

UINT32

RO

0x6003:14, 32

1A12:15

SubIndex 021

21. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x15 (Sample))

UINT32

RO

0x6003:15, 32

1A12:16

SubIndex 022

22. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x16 (Sample))

UINT32

RO

0x6003:16, 32

1A12:17

SubIndex 023

23. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x17 (Sample))

UINT32

RO

0x6003:17, 32

1A12:18

SubIndex 024

24. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x18 (Sample))

UINT32

RO

0x6003:18, 32

1A12:19

SubIndex 025

25. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x19 (Sample))

UINT32

RO

0x6003:19, 32

1A12:1A

SubIndex 026

26. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x1A (Sample))

UINT32

RO

0x6003:1A, 32

1A12:1B

SubIndex 027

27. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x1B (Sample))

UINT32

RO

0x6003:1B, 32

1A12:1C

SubIndex 028

28. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x1C (Sample))

UINT32

RO

0x6003:1C, 32

1A12:1D

SubIndex 029

29. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x1D (Sample))

UINT32

RO

0x6003:1D, 32

Index (hex)

Name

Meaning

Data type

Flags

Default

1A12:1E

SubIndex 030

30. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x1E (Sample))

UINT32

RO

0x6003:1E, 32

1A12:1F

SubIndex 031

31. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x1F (Sample))

UINT32

RO

0x6003:1F, 32

1A12:20

SubIndex 032

32. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x20 (Sample))

UINT32

RO

0x6003:20, 32

1A12:21

SubIndex 033

33. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x21 (Sample))

UINT32

RO

0x6003:21, 32

1A12:22

SubIndex 034

34. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x22 (Sample))

UINT32

RO

0x6003:22, 32

1A12:23

SubIndex 035

35. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x23 (Sample))

UINT32

RO

0x6003:23, 32

1A12:24

SubIndex 036

36. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x24 (Sample))

UINT32

RO

0x6003:24, 32

1A12:25

SubIndex 037

37. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x25 (Sample))

UINT32

RO

0x6003:25, 32

1A12:26

SubIndex 038

38. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x26 (Sample))

UINT32

RO

0x6003:26, 32

1A12:27

SubIndex 039

39. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x27 (Sample))

UINT32

RO

0x6003:27, 32

1A12:28

SubIndex 040

40. PDO Mapping entry (object 0x6003 (AI Acc Samples (Real32)), entry 0x28 (Sample))

UINT32

RO

0x6003:28, 32

Index 1A13 AI Acc X TxPDO-Map Samples 40

Index (hex)

Name

Meaning

Data type

Flags

Default

1A13:0

AI Acc X TxPDO-Map Samples 40

PDO Mapping TxPDO 20

UINT8

RO

0x28 (40dec)

1A13:01

SubIndex 001

1. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x01 (Sample))

UINT32

RO

0x6001:01, 32

1A13:02

SubIndex 002

2. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x02 (Sample))

UINT32

RO

0x6001:02, 32

1A13:03

SubIndex 003

3. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x03 (Sample))

UINT32

RO

0x6001:03, 32

1A13:04

SubIndex 004

4. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x04 (Sample))

UINT32

RO

0x6001:04, 32

1A13:05

SubIndex 005

5. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x05 (Sample))

UINT32

RO

0x6001:05, 32

1A13:06

SubIndex 006

6. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x06 (Sample))

UINT32

RO

0x6001:06, 32

1A13:07

SubIndex 007

7. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x07 (Sample))

UINT32

RO

0x6001:07, 32

1A13:08

SubIndex 008

8. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x08 (Sample))

UINT32

RO

0x6001:08, 32

1A13:09

SubIndex 009

9. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x09 (Sample))

UINT32

RO

0x6001:09, 32

1A13:0A

SubIndex 010

10. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x0A (Sample))

UINT32

RO

0x6001:0A, 32

1A13:0B

SubIndex 011

11. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x0B (Sample))

UINT32

RO

0x6001:0B, 32

1A13:0C

SubIndex 012

12. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x0C (Sample))

UINT32

RO

0x6001:0C, 32

1A13:0D

SubIndex 013

13. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x0D (Sample))

UINT32

RO

0x6001:0D, 32

Index (hex)

Name

Meaning

Data type

Flags

Default

1A13:0E

SubIndex 014

14. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x0E (Sample))

UINT32

RO

0x6001:0E, 32

1A13:0F

SubIndex 015

15. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x0F (Sample))

UINT32

RO

0x6001:0F, 32

1A13:10

SubIndex 016

16. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x10 (Sample))

UINT32

RO

0x6001:10, 32

1A13:11

SubIndex 017

17. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x11 (Sample))

UINT32

RO

0x6001:11, 32

1A13:12

SubIndex 018

18. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x12 (Sample))

UINT32

RO

0x6001:12, 32

1A13:13

SubIndex 019

19. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x13 (Sample))

UINT32

RO

0x6001:13, 32

1A13:14

SubIndex 020

20. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x14 (Sample))

UINT32

RO

0x6001:14, 32

1A13:15

SubIndex 021

21. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x15 (Sample))

UINT32

RO

0x6001:15, 32

1A13:16

SubIndex 022

22. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x16 (Sample))

UINT32

RO

0x6001:16, 32

1A13:17

SubIndex 023

23. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x17 (Sample))

UINT32

RO

0x6001:17, 32

1A13:18

SubIndex 024

24. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x18 (Sample))

UINT32

RO

0x6001:18, 32

1A13:19

SubIndex 025

25. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x19 (Sample))

UINT32

RO

0x6001:19, 32

1A13:1A

SubIndex 026

26. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x1A (Sample))

UINT32

RO

0x6001:1A, 32

1A13:1B

SubIndex 027

27. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x1B (Sample))

UINT32

RO

0x6001:1B, 32

1A13:1C

SubIndex 028

28. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x1C (Sample))

UINT32

RO

0x6001:1C, 32

1A13:1D

SubIndex 029

29. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x1D (Sample))

UINT32

RO

0x6001:1D, 32

1A13:1E

SubIndex 030

30. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x1E (Sample))

UINT32

RO

0x6001:1E, 32

1A13:1F

SubIndex 031

31. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x1F (Sample))

UINT32

RO

0x6001:1F, 32

1A13:20

SubIndex 032

32. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x20 (Sample))

UINT32

RO

0x6001:20, 32

1A13:21

SubIndex 033

33. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x21 (Sample))

UINT32

RO

0x6001:21, 32

1A13:22

SubIndex 034

34. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x22 (Sample))

UINT32

RO

0x6001:22, 32

1A13:23

SubIndex 035

35. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x23 (Sample))

UINT32

RO

0x6001:23, 32

1A13:24

SubIndex 036

36. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x24 (Sample))

UINT32

RO

0x6001:24, 32

1A13:25

SubIndex 037

37. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x25 (Sample))

UINT32

RO

0x6001:25, 32

1A13:26

SubIndex 038

38. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x26 (Sample))

UINT32

RO

0x6001:26, 32

1A13:27

SubIndex 039

39. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x27 (Sample))

UINT32

RO

0x6001:27, 32

1A13:28

SubIndex 040

40. PDO Mapping entry (object 0x6001 (AI Acc Samples), entry 0x28 (Sample))

UINT32

RO

0x6001:28, 32

Index 1A20 AI Acc Y TxPDO-Map Status

Index (hex)

Name

Meaning

Data type

Flags

Default

1A20:0

AI Acc Y TxPDO-Map Status

PDO Mapping TxPDO 33

UINT8

RO

0x08 (8dec)

1A20:01

SubIndex 001

1. PDO Mapping entry (8 bits align)

UINT32

RO

0x0000:00, 8

1A20:02

SubIndex 002

2. PDO Mapping entry (object 0x6020 (AI Acc Inputs), entry 0x09 (Self test status))

UINT32

RO

0x6010:09, 2

1A20:03

SubIndex 003

3. PDO Mapping entry (object 0x6020 (AI Acc Inputs), entry 0x0B (Slope detected))

UINT32

RO

0x6010:0B, 1

1A20:04

SubIndex 004

4. PDO Mapping entry (3 bits align)

UINT32

RO

0x0000:00, 2

1A20:05

SubIndex 005

5. PDO Mapping entry (object 0x6020 (AI Acc Inputs), entry 0x0F (TxPDO State))

UINT32

RO

0x6010:0E, 1

1A20:06

SubIndex 006

6. PDO Mapping entry (object 0x6020 (AI Acc Inputs), entry 0x10 (TxPDO Toggle))

UINT32

RO

0x6010:0F, 1

1A20:07

SubIndex 007

7. PDO Mapping entry (16 bits align)

UINT32

RO

0x6010:10, 1

1A20:08

SubIndex 008

8. PDO Mapping entry (16 bits align)

UINT32

RO

0x0000:00, 16

Index 1A21 AI Acc Y TxPDO-Map Input Cycle Counter

Index (hex)

Name

Meaning

Data type

Flags

Default

1A21:0

AI Acc Y TxPDO-Map Input Cycle Counter

PDO Mapping TxPDO 34

UINT8

RO

0x01 (1dec)

1A21:01

SubIndex 001

1. PDO Mapping entry (8 bits align)

UINT32

RO

0x6010:14, 16

Index 1A22 AI Acc Y TxPDO-Map Input Legacy Real

Index (hex)

Name

Meaning

Data type

Flags

Default

1A22:0

AI Acc Y TxPDO-Map Input Legacy Real

PDO Mapping TxPDO 35

UINT8

RO

0x09 (9dec)

1A22:01

SubIndex 001

1. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x0000:00, 8

1A22:02

SubIndex 002

2. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6010:09, 2

1A22:03

SubIndex 003

3. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6010:0B, 1

1A22:04

SubIndex 004

4. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x0000:00, 2

1A22:05

SubIndex 005

5. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x05 (Sample))

UINT32

RO

0x6010:0E, 1

1A22:06

SubIndex 006

6. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x06 (Sample))

UINT32

RO

0x6010:0F, 1

1A22:07

SubIndex 007

7. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x07 (Sample))

UINT32

RO

0x6010:10, 1

1A22:08

SubIndex 008

8. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x08 (Sample))

UINT32

RO

0x0000:00, 16

1A22:09

SubIndex 009

9. PDO Mapping entry (object 0x6010 (AI Acc Inputs), entry 0x13 (Value (Real32)))

UINT32

RO

0x6010:13, 32

Index 1A23 AI Acc Y TxPDO-Map Input Legacy Int

Index (hex)

Name

Meaning

Data type

Flags

Default

1A23:0

AI Acc Y TxPDO-Map Input Legacy Int

PDO Mapping TxPDO 36

UINT8

RO

0x09 (9dec)

1A23:01

SubIndex 001

1. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x01 (Sample))

UINT32

RO

0x0000:00, 8

1A23:02

SubIndex 002

2. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x02 (Sample))

UINT32

RO

0x6010:09, 2

1A23:03

SubIndex 003

3. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x03 (Sample))

UINT32

RO

0x6010:0B, 1

1A23:04

SubIndex 004

4. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x04 (Sample))

UINT32

RO

0x0000:00, 2

1A23:05

SubIndex 005

5. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x05 (Sample))

UINT32

RO

0x6010:0E, 1

1A23:06

SubIndex 006

6. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x06 (Sample))

UINT32

RO

0x6010:0F, 1

1A23:07

SubIndex 007

7. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x07 (Sample))

UINT32

RO

0x6010:10, 1

1A23:08

SubIndex 008

8. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x08 (Sample))

UINT32

RO

0x0000:00, 16

1A23:09

SubIndex 009

9. PDO Mapping entry (object 0x6010 (AI Acc Inputs), entry 0x12 (Value))

UINT32

RO

0x6010:12, 32

Index 1A24 AI Acc Y TxPDO-Map Samples 1 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A24:0

AI Acc Y TxPDO-Map Samples 1 (Real32)

PDO Mapping TxPDO 37

UINT8

RO

0x01 (1dec)

1A24:01

SubIndex 001

1. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6013:01, 32

Index 1A25 AI Acc Y TxPDO-Map Samples 1

Index (hex)

Name

Meaning

Data type

Flags

Default

1A25:0

AI Acc Y TxPDO-Map Samples 1

PDO Mapping TxPDO 38

UINT8

RO

0x01 (1dec)

1A25:01

SubIndex 001

1. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x01 (Sample))

UINT32

RO

0x6011:01, 32

Index 1A26 AI Acc Y TxPDO-Map Samples 2 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A26:0

AI Acc Y TxPDO-Map Samples 2 (Real32)

PDO Mapping TxPDO 39

UINT8

RO

0x02 (2dec)

1A26:01

SubIndex 001

1. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6013:01, 32

1A26:02

SubIndex 002

2. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6013:02, 32

Index 1A27 AI Acc Y TxPDO-Map Samples 2

Index (hex)

Name

Meaning

Data type

Flags

Default

1A27:0

AI Acc Y TxPDO-Map Samples 2

PDO Mapping TxPDO 40

UINT8

RO

0x02 (2dec)

1A27:01

SubIndex 001

1. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x01 (Sample))

UINT32

RO

0x6011:01, 32

1A27:02

SubIndex 002

2. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x02 (Sample))

UINT32

RO

0x6011:02, 32

Index 1A28 AI Acc Y TxPDO-Map Samples 4 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A28:0

AI Acc Y TxPDO-Map Samples 4 (Real32)

PDO Mapping TxPDO 41

UINT8

RO

0x04 (4dec)

1A28:01

SubIndex 001

1. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6013:01, 32

1A28:02

SubIndex 002

2. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6013:02, 32

1A28:03

SubIndex 003

3. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6013:03, 32

1A28:04

SubIndex 004

4. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6013:04, 32

Index 1A29 AI Acc Y TxPDO-Map Samples 4

Index (hex)

Name

Meaning

Data type

Flags

Default

1A29:0

AI Acc Y TxPDO-Map Samples 4

PDO Mapping TxPDO 42

UINT8

RO

0x04 (4dec)

1A29:01

SubIndex 001

1. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x01 (Sample))

UINT32

RO

0x6011:01, 32

1A29:02

SubIndex 002

2. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x02 (Sample))

UINT32

RO

0x6011:02, 32

1A29:03

SubIndex 003

3. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x03 (Sample))

UINT32

RO

0x6011:03, 32

1A29:04

SubIndex 004

4. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x04 (Sample))

UINT32

RO

0x6011:04, 32

Index 1A2A AI Acc Y TxPDO-Map Samples 8 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A2A:0

AI Acc Y TxPDO-Map Samples 8 (Real32)

PDO Mapping TxPDO 43

UINT8

RO

0x08 (8dec)

1A2A:01

SubIndex 001

1. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6013:01, 32

1A2A:02

SubIndex 002

2. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6013:02, 32

1A2A:03

SubIndex 003

3. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6013:03, 32

1A2A:04

SubIndex 004

4. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6013:04, 32

1A2A:05

SubIndex 005

5. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x05 (Sample))

UINT32

RO

0x6013:05, 32

1A2A:06

SubIndex 006

6. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x06 (Sample))

UINT32

RO

0x6013:06, 32

1A2A:07

SubIndex 007

7. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x07 (Sample))

UINT32

RO

0x6013:07, 32

1A2A:08

SubIndex 008

8. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x08 (Sample))

UINT32

RO

0x6013:08, 32

Index 1A2B AI Acc Y TxPDO-Map Samples 8

Index (hex)

Name

Meaning

Data type

Flags

Default

1A2B:0

AI Acc Y TxPDO-Map Samples 8

PDO Mapping TxPDO 44

UINT8

RO

0x08 (8dec)

1A2B:01

SubIndex 001

1. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x01 (Sample))

UINT32

RO

0x6011:01, 32

1A2B:02

SubIndex 002

2. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x02 (Sample))

UINT32

RO

0x6011:02, 32

1A2B:03

SubIndex 003

3. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x03 (Sample))

UINT32

RO

0x6011:03, 32

1A2B:04

SubIndex 004

4. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x04 (Sample))

UINT32

RO

0x6011:04, 32

1A2B:05

SubIndex 005

5. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x05 (Sample))

UINT32

RO

0x6011:05, 32

1A2B:06

SubIndex 006

6. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x06 (Sample))

UINT32

RO

0x6011:06, 32

1A2B:07

SubIndex 007

7. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x07 (Sample))

UINT32

RO

0x6011:07, 32

1A2B:08

SubIndex 008

8. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x08 (Sample))

UINT32

RO

0x6011:08, 32

Index 1A2C AI Acc Y TxPDO-Map Samples 10 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A2C:0

AI Acc Y TxPDO-Map Samples 10 (Real32)

PDO Mapping TxPDO 45

UINT8

RO

0x0A (10dec)

1A2C:01

SubIndex 001

1. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6013:01, 32

1A2C:02

SubIndex 002

2. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6013:02, 32

1A2C:03

SubIndex 003

3. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6013:03, 32

1A2C:04

SubIndex 004

4. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6013:04, 32

1A2C:05

SubIndex 005

5. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x05 (Sample))

UINT32

RO

0x6013:05, 32

1A2C:06

SubIndex 006

6. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x06 (Sample))

UINT32

RO

0x6013:06, 32

1A2C:07

SubIndex 007

7. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x07 (Sample))

UINT32

RO

0x6013:07, 32

1A2C:08

SubIndex 008

8. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x08 (Sample))

UINT32

RO

0x6013:08, 32

1A2C:09

SubIndex 009

9. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x09 (Sample))

UINT32

RO

0x6013:09, 32

1A2C:0A

SubIndex 010

10. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x0A (Sample))

UINT32

RO

0x6013:0A, 32

Index 1A2D AI Acc Y TxPDO-Map Samples 10

Index (hex)

Name

Meaning

Data type

Flags

Default

1A2D:0

AI Acc Y TxPDO-Map Samples 10

PDO Mapping TxPDO 46

UINT8

RO

0x0A (10dec)

1A2D:01

SubIndex 001

1. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x01 (Sample))

UINT32

RO

0x6011:01, 32

1A2D:02

SubIndex 002

2. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x02 (Sample))

UINT32

RO

0x6011:02, 32

1A2D:03

SubIndex 003

3. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x03 (Sample))

UINT32

RO

0x6011:03, 32

1A2D:04

SubIndex 004

4. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x04 (Sample))

UINT32

RO

0x6011:04, 32

1A2D:05

SubIndex 005

5. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x05 (Sample))

UINT32

RO

0x6011:05, 32

1A2D:06

SubIndex 006

6. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x06 (Sample))

UINT32

RO

0x6011:06, 32

1A2D:07

SubIndex 007

7. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x07 (Sample))

UINT32

RO

0x6011:07, 32

1A2D:08

SubIndex 008

8. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x08 (Sample))

UINT32

RO

0x6011:08, 32

1A2D:09

SubIndex 009

9. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x09 (Sample))

UINT32

RO

0x6011:09, 32

1A2D:0A

SubIndex 010

10. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x0A (Sample))

UINT32

RO

0x6011:0A, 32

Index 1A2E AI Acc Y TxPDO-Map Samples 16 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A2E:0

AI Acc Y TxPDO-Map Samples 16 (Real32)

PDO Mapping TxPDO 47

UINT8

RO

0x10 (16dec)

1A2E:01

SubIndex 001

1. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6013:01, 32

1A2E:02

SubIndex 002

2. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6013:02, 32

1A2E:03

SubIndex 003

3. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6013:03, 32

1A2E:04

SubIndex 004

4. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6013:04, 32

1A2E:05

SubIndex 005

5. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x05 (Sample))

UINT32

RO

0x6013:05, 32

1A2E:06

SubIndex 006

6. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x06 (Sample))

UINT32

RO

0x6013:06, 32

1A2E:07

SubIndex 007

7. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x07 (Sample))

UINT32

RO

0x6013:07, 32

1A2E:08

SubIndex 008

8. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x08 (Sample))

UINT32

RO

0x6013:08, 32

1A2E:09

SubIndex 009

9. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x09 (Sample))

UINT32

RO

0x6013:09, 32

1A2E:0A

SubIndex 010

10. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x0A (Sample))

UINT32

RO

0x6013:0A, 32

1A2E:0B

SubIndex 011

11. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x0B (Sample))

UINT32

RO

0x6013:0B, 32

1A2E:0C

SubIndex 012

12. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x0C (Sample))

UINT32

RO

0x6013:0C, 32

1A2E:0D

SubIndex 013

13. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x0D (Sample))

UINT32

RO

0x6013:0D, 32

1A2E:0E

SubIndex 014

14. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x0E (Sample))

UINT32

RO

0x6013:0E, 32

1A2E:0F

SubIndex 015

15. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x0F (Sample))

UINT32

RO

0x6013:0F, 32

1A2E:10

SubIndex 016

16. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x10 (Sample))

UINT32

RO

0x6013:10, 32

Index 1A2F AI Acc Y TxPDO-Map Samples 16

Index (hex)

Name

Meaning

Data type

Flags

Default

1A2F:0

AI Acc Y TxPDO-Map Samples 16

PDO Mapping TxPDO 48

UINT8

RO

0x10 (16dec)

1A2F:01

SubIndex 001

1. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x01 (Sample))

UINT32

RO

0x6011:01, 32

1A2F:02

SubIndex 002

2. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x02 (Sample))

UINT32

RO

0x6011:02, 32

1A2F:03

SubIndex 003

3. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x03 (Sample))

UINT32

RO

0x6011:03, 32

1A2F:04

SubIndex 004

4. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x04 (Sample))

UINT32

RO

0x6011:04, 32

1A2F:05

SubIndex 005

5. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x05 (Sample))

UINT32

RO

0x6011:05, 32

1A2F:06

SubIndex 006

6. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x06 (Sample))

UINT32

RO

0x6011:06, 32

1A2F:07

SubIndex 007

7. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x07 (Sample))

UINT32

RO

0x6011:07, 32

1A2F:08

SubIndex 008

8. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x08 (Sample))

UINT32

RO

0x6011:08, 32

1A2F:09

SubIndex 009

9. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x09 (Sample))

UINT32

RO

0x6011:09, 32

1A2F:0A

SubIndex 010

10. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x0A (Sample))

UINT32

RO

0x6011:0A, 32

1A2F:0B

SubIndex 011

11. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x0B (Sample))

UINT32

RO

0x6011:0B, 32

1A2F:0C

SubIndex 012

12. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x0C (Sample))

UINT32

RO

0x6011:0C, 32

1A2F:0D

SubIndex 013

13. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x0D (Sample))

UINT32

RO

0x6011:0D, 32

1A2F:0E

SubIndex 014

14. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x0E (Sample))

UINT32

RO

0x6011:0E, 32

1A2F:0F

SubIndex 015

15. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x0F (Sample))

UINT32

RO

0x6011:0F, 32

1A2F:10

SubIndex 016

16. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x10 (Sample))

UINT32

RO

0x6011:10, 32

Index 1A30 AI Acc Y TxPDO-Map Samples 20 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A30:0

AI Acc Y TxPDO-Map Samples 20 (Real32)

PDO Mapping TxPDO 49

UINT8

RO

0x14 (20dec)

1A30:01

SubIndex 001

1. PDO Mapping entry (8 bits align)

UINT32

RO

0x6013:01, 32

1A30:02

SubIndex 002

2. PDO Mapping entry (object 0x6030 (AI Gyro Inputs), entry 0x09 (Self test status))

UINT32

RO

0x6013:02, 32

1A30:03

SubIndex 003

3. PDO Mapping entry (object 0x6030 (AI Gyro Inputs), entry 0x0B (Slope detected))

UINT32

RO

0x6013:03, 32

1A30:04

SubIndex 004

4. PDO Mapping entry (3 bits align)

UINT32

RO

0x6013:04, 32

1A30:05

SubIndex 005

5. PDO Mapping entry (object 0x6030 (AI Gyro Inputs), entry 0x0F (TxPDO State))

UINT32

RO

0x6013:05, 32

1A30:06

SubIndex 006

6. PDO Mapping entry (object 0x6030 (AI Gyro Inputs), entry 0x10 (TxPDO Toggle))

UINT32

RO

0x6013:06, 32

1A30:07

SubIndex 007

7. PDO Mapping entry (16 bits align)

UINT32

RO

0x6013:07, 32

1A30:08

SubIndex 008

8. PDO Mapping entry (object 0x6030 (AI Gyro Inputs), entry 0x12 (Value))

UINT32

RO

0x6013:08, 32

1A30:09

SubIndex 009

9. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x09 (Sample))

UINT32

RO

0x6013:09, 32

1A30:0A

SubIndex 010

10. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x0A (Sample))

UINT32

RO

0x6013:0A, 32

1A30:0B

SubIndex 011

11. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x0B (Sample))

UINT32

RO

0x6013:0B, 32

1A30:0C

SubIndex 012

12. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x0C (Sample))

UINT32

RO

0x6013:0C, 32

1A30:0D

SubIndex 013

13. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x0D (Sample))

UINT32

RO

0x6013:0D, 32

1A30:0E

SubIndex 014

14. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x0E (Sample))

UINT32

RO

0x6013:0E, 32

1A30:0F

SubIndex 015

15. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x0F (Sample))

UINT32

RO

0x6013:0F, 32

1A30:10

SubIndex 016

16. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x10 (Sample))

UINT32

RO

0x6013:10, 32

1A30:11

SubIndex 017

17. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x11 (Sample))

UINT32

RO

0x6013:11, 32

1A30:12

SubIndex 018

18. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x12 (Sample))

UINT32

RO

0x6013:12, 32

1A30:13

SubIndex 019

19. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x13 (Sample))

UINT32

RO

0x6013:13, 32

1A30:14

SubIndex 020

20. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x14 (Sample))

UINT32

RO

0x6013:14, 32

Index 1A31 AI Acc Y TxPDO-Map Samples 20

Index (hex)

Name

Meaning

Data type

Flags

Default

1A31:0

AI Acc Y TxPDO-Map Samples 20

PDO Mapping TxPDO 50

UINT8

RO

0x14 (20dec)

1A31:01

SubIndex 001

1. PDO Mapping entry (8 bits align)

UINT32

RO

0x6011:01, 32

1A31:02

SubIndex 002

2. PDO Mapping entry (object 0x6040 (AI Gyro Inputs), entry 0x09 (Self test status))

UINT32

RO

0x6011:02, 32

1A31:03

SubIndex 003

3. PDO Mapping entry (object 0x6040 (AI Gyro Inputs), entry 0x0B (Slope detected))

UINT32

RO

0x6011:03, 32

1A31:04

SubIndex 004

4. PDO Mapping entry (3 bits align)

UINT32

RO

0x6011:04, 32

1A31:05

SubIndex 005

5. PDO Mapping entry (object 0x6040 (AI Gyro Inputs), entry 0x0F (TxPDO State))

UINT32

RO

0x6011:05, 32

1A31:06

SubIndex 006

6. PDO Mapping entry (object 0x6040 (AI Gyro Inputs), entry 0x10 (TxPDO Toggle))

UINT32

RO

0x6011:06, 32

1A31:07

SubIndex 007

7. PDO Mapping entry (16 bits align)

UINT32

RO

0x6011:07, 32

1A31:08

SubIndex 008

8. PDO Mapping entry (object 0x6040 (AI Gyro Inputs), entry 0x12 (Value))

UINT32

RO

0x6011:08, 32

1A31:09

SubIndex 009

9. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x09 (Sample))

UINT32

RO

0x6011:09, 32

1A31:0A

SubIndex 010

10. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x0A (Sample))

UINT32

RO

0x6011:0A, 32

1A31:0B

SubIndex 011

11. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x0B (Sample))

UINT32

RO

0x6011:0B, 32

1A31:0C

SubIndex 012

12. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x0C (Sample))

UINT32

RO

0x6011:0C, 32

1A31:0D

SubIndex 013

13. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x0D (Sample))

UINT32

RO

0x6011:0D, 32

1A31:0E

SubIndex 014

14. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x0E (Sample))

UINT32

RO

0x6011:0E, 32

1A31:0F

SubIndex 015

15. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x0F (Sample))

UINT32

RO

0x6011:0F, 32

1A31:10

SubIndex 016

16. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x10 (Sample))

UINT32

RO

0x6011:10, 32

1A31:11

SubIndex 017

17. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x11 (Sample))

UINT32

RO

0x6011:11, 32

1A31:12

SubIndex 018

18. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x12 (Sample))

UINT32

RO

0x6011:12, 32

1A31:13

SubIndex 019

19. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x13 (Sample))

UINT32

RO

0x6011:13, 32

1A31:14

SubIndex 020

20. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x14 (Sample))

UINT32

RO

0x6011:14, 32

Index 1A32 AI Acc Y TxPDO-Map Samples 40 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A32:0

AI Acc Y TxPDO-Map Samples 40 (Real32)

PDO Mapping TxPDO 51

UINT8

RO

0x28 (40dec)

1A32:01

SubIndex 001

1. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6013:01, 32

1A32:02

SubIndex 002

2. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6013:02, 32

1A32:03

SubIndex 003

3. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6013:03, 32

1A32:04

SubIndex 004

4. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6013:04, 32

1A32:05

SubIndex 005

5. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x05 (Sample))

UINT32

RO

0x6013:05, 32

1A32:06

SubIndex 006

6. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x06 (Sample))

UINT32

RO

0x6013:06, 32

1A32:07

SubIndex 007

7. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x07 (Sample))

UINT32

RO

0x6013:07, 32

1A32:08

SubIndex 008

8. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x08 (Sample))

UINT32

RO

0x6013:08, 32

1A32:09

SubIndex 009

9. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x09 (Sample))

UINT32

RO

0x6013:09, 32

1A32:0A

SubIndex 010

10. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x0A (Sample))

UINT32

RO

0x6013:0A, 32

1A32:0B

SubIndex 011

11. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x0B (Sample))

UINT32

RO

0x6013:0B, 32

1A32:0C

SubIndex 012

12. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x0C (Sample))

UINT32

RO

0x6013:0C, 32

1A32:0D

SubIndex 013

13. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x0D (Sample))

UINT32

RO

0x6013:0D, 32

1A32:0E

SubIndex 014

14. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x0E (Sample))

UINT32

RO

0x6013:0E, 32

1A32:0F

SubIndex 015

15. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x0F (Sample))

UINT32

RO

0x6013:0F, 32

1A32:10

SubIndex 016

16. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x10 (Sample))

UINT32

RO

0x6013:10, 32

1A32:11

SubIndex 017

17. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x11 (Sample))

UINT32

RO

0x6013:11, 32

1A32:12

SubIndex 018

18. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x12 (Sample))

UINT32

RO

0x6013:12, 32

1A32:13

SubIndex 019

19. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x13 (Sample))

UINT32

RO

0x6013:13, 32

1A32:14

SubIndex 020

20. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x14 (Sample))

UINT32

RO

0x6013:14, 32

1A32:15

SubIndex 021

21. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x15 (Sample))

UINT32

RO

0x6013:15, 32

1A32:16

SubIndex 022

22. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x16 (Sample))

UINT32

RO

0x6013:16, 32

1A32:17

SubIndex 023

23. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x17 (Sample))

UINT32

RO

0x6013:17, 32

1A32:18

SubIndex 024

24. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x18 (Sample))

UINT32

RO

0x6013:18, 32

1A32:19

SubIndex 025

25. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x19 (Sample))

UINT32

RO

0x6013:19, 32

1A32:1A

SubIndex 026

26. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x1A (Sample))

UINT32

RO

0x6013:1A, 32

1A32:1B

SubIndex 027

27. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x1B (Sample))

UINT32

RO

0x6013:1B, 32

1A32:1C

SubIndex 028

28. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x1C (Sample))

UINT32

RO

0x6013:1C, 32

1A32:1D

SubIndex 029

29. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x1D (Sample))

UINT32

RO

0x6013:1D, 32

Index (hex)

Name

Meaning

Data type

Flags

Default

1A32:1E

SubIndex 030

30. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x1E (Sample))

UINT32

RO

0x6013:1E, 32

1A32:1F

SubIndex 031

31. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x1F (Sample))

UINT32

RO

0x6013:1F, 32

1A32:20

SubIndex 032

32. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x20 (Sample))

UINT32

RO

0x6013:20, 32

1A32:21

SubIndex 033

33. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x21 (Sample))

UINT32

RO

0x6013:21, 32

1A32:22

SubIndex 034

34. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x22 (Sample))

UINT32

RO

0x6013:22, 32

1A32:23

SubIndex 035

35. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x23 (Sample))

UINT32

RO

0x6013:23, 32

1A32:24

SubIndex 036

36. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x24 (Sample))

UINT32

RO

0x6013:24, 32

1A32:25

SubIndex 037

37. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x25 (Sample))

UINT32

RO

0x6013:25, 32

1A32:26

SubIndex 038

38. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x26 (Sample))

UINT32

RO

0x6013:26, 32

1A32:27

SubIndex 039

39. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x27 (Sample))

UINT32

RO

0x6013:27, 32

1A32:28

SubIndex 040

40. PDO Mapping entry (object 0x6013 (AI Acc Samples (Real32)), entry 0x28 (Sample))

UINT32

RO

0x6013:28, 32

Index 1A33 AI Acc Y TxPDO-Map Samples 40

Index (hex)

Name

Meaning

Data type

Flags

Default

1A33:0

AI Acc Y TxPDO-Map Samples 40

PDO Mapping TxPDO 52

UINT8

RO

0x28 (40dec)

1A33:01

SubIndex 001

1. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x01 (Sample))

UINT32

RO

0x6011:01, 32

1A33:02

SubIndex 002

2. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x02 (Sample))

UINT32

RO

0x6011:02, 32

1A33:03

SubIndex 003

3. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x03 (Sample))

UINT32

RO

0x6011:03, 32

1A33:04

SubIndex 004

4. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x04 (Sample))

UINT32

RO

0x6011:04, 32

1A33:05

SubIndex 005

5. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x05 (Sample))

UINT32

RO

0x6011:05, 32

1A33:06

SubIndex 006

6. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x06 (Sample))

UINT32

RO

0x6011:06, 32

1A33:07

SubIndex 007

7. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x07 (Sample))

UINT32

RO

0x6011:07, 32

1A33:08

SubIndex 008

8. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x08 (Sample))

UINT32

RO

0x6011:08, 32

1A33:09

SubIndex 009

9. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x09 (Sample))

UINT32

RO

0x6011:09, 32

1A33:0A

SubIndex 010

10. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x0A (Sample))

UINT32

RO

0x6011:0A, 32

1A33:0B

SubIndex 011

11. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x0B (Sample))

UINT32

RO

0x6011:0B, 32

1A33:0C

SubIndex 012

12. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x0C (Sample))

UINT32

RO

0x6011:0C, 32

1A33:0D

SubIndex 013

13. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x0D (Sample))

UINT32

RO

0x6011:0D, 32

Index (hex)

Name

Meaning

Data type

Flags

Default

1A33:0E

SubIndex 014

14. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x0E (Sample))

UINT32

RO

0x6011:0E, 32

1A33:0F

SubIndex 015

15. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x0F (Sample))

UINT32

RO

0x6011:0F, 32

1A33:10

SubIndex 016

16. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x10 (Sample))

UINT32

RO

0x6011:10, 32

1A33:11

SubIndex 017

17. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x11 (Sample))

UINT32

RO

0x6011:11, 32

1A33:12

SubIndex 018

18. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x12 (Sample))

UINT32

RO

0x6011:12, 32

1A33:13

SubIndex 019

19. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x13 (Sample))

UINT32

RO

0x6011:13, 32

1A33:14

SubIndex 020

20. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x14 (Sample))

UINT32

RO

0x6011:14, 32

1A33:15

SubIndex 021

21. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x15 (Sample))

UINT32

RO

0x6011:15, 32

1A33:16

SubIndex 022

22. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x16 (Sample))

UINT32

RO

0x6011:16, 32

1A33:17

SubIndex 023

23. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x17 (Sample))

UINT32

RO

0x6011:17, 32

1A33:18

SubIndex 024

24. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x18 (Sample))

UINT32

RO

0x6011:18, 32

1A33:19

SubIndex 025

25. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x19 (Sample))

UINT32

RO

0x6011:19, 32

1A33:1A

SubIndex 026

26. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x1A (Sample))

UINT32

RO

0x6011:1A, 32

1A33:1B

SubIndex 027

27. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x1B (Sample))

UINT32

RO

0x6011:1B, 32

1A33:1C

SubIndex 028

28. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x1C (Sample))

UINT32

RO

0x6011:1C, 32

1A33:1D

SubIndex 029

29. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x1D (Sample))

UINT32

RO

0x6011:1D, 32

1A33:1E

SubIndex 030

30. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x1E (Sample))

UINT32

RO

0x6011:1E, 32

1A33:1F

SubIndex 031

31. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x1F (Sample))

UINT32

RO

0x6011:1F, 32

1A33:20

SubIndex 032

32. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x20 (Sample))

UINT32

RO

0x6011:20, 32

1A33:21

SubIndex 033

33. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x21 (Sample))

UINT32

RO

0x6011:21, 32

1A33:22

SubIndex 034

34. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x22 (Sample))

UINT32

RO

0x6011:22, 32

1A33:23

SubIndex 035

35. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x23 (Sample))

UINT32

RO

0x6011:23, 32

1A33:24

SubIndex 036

36. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x24 (Sample))

UINT32

RO

0x6011:24, 32

1A33:25

SubIndex 037

37. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x25 (Sample))

UINT32

RO

0x6011:25, 32

1A33:26

SubIndex 038

38. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x26 (Sample))

UINT32

RO

0x6011:26, 32

1A33:27

SubIndex 039

39. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x27 (Sample))

UINT32

RO

0x6011:27, 32

1A33:28

SubIndex 040

40. PDO Mapping entry (object 0x6011 (AI Acc Samples), entry 0x28 (Sample))

UINT32

RO

0x6011:28, 32

Index 1A40 AI Acc Z TxPDO-Map Status

Index (hex)

Name

Meaning

Data type

Flags

Default

1A40:0

AI Acc Z TxPDO-Map Status

PDO Mapping TxPDO 65

UINT8

RO

0x08 (8dec)

1A40:01

SubIndex 001

1. PDO Mapping entry (8 bits align)

UINT32

RO

0x0000:00, 8

1A40:02

SubIndex 002

2. PDO Mapping entry (object 0x6040 (AI Gyro Inputs), entry 0x09 (Self test status))

UINT32

RO

0x6020:09, 2

1A40:03

SubIndex 003

3. PDO Mapping entry (object 0x6040 (AI Gyro Inputs), entry 0x0B (Slope detected))

UINT32

RO

0x6020:0B, 1

1A40:04

SubIndex 004

4. PDO Mapping entry (3 bits align)

UINT32

RO

0x0000:00, 2

1A40:05

SubIndex 005

5. PDO Mapping entry (object 0x6040 (AI Gyro Inputs), entry 0x0F (TxPDO State))

UINT32

RO

0x6020:0E, 1

1A40:06

SubIndex 006

6. PDO Mapping entry (object 0x6040 (AI Gyro Inputs), entry 0x10 (TxPDO Toggle))

UINT32

RO

0x6020:0F, 1

1A40:07

SubIndex 007

7. PDO Mapping entry (16 bits align)

UINT32

RO

0x6020:10, 1

1A40:08

SubIndex 008

8. PDO Mapping entry (16 bits align)

UINT32

RO

0x0000:00, 16

Index 1A41 AI Acc Z TxPDO-Map Input Cycle Counter

Index (hex)

Name

Meaning

Data type

Flags

Default

1A41:0

AI Acc Z TxPDO-Map Input Cycle Counter

PDO Mapping TxPDO 66

UINT8

RO

0x01 (1dec)

1A41:01

SubIndex 001

1. PDO Mapping entry (8 bits align)

UINT32

RO

0x6020:14, 16

Index 1A42 AI Acc Z TxPDO-Map Input Legacy Real

Index (hex)

Name

Meaning

Data type

Flags

Default

1A42:0

AI Acc Z TxPDO-Map Input Legacy Real

PDO Mapping TxPDO 67

UINT8

RO

0x09 (9dec)

1A42:01

SubIndex 001

1. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x0000:00, 8

1A42:02

SubIndex 002

2. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6020:09, 2

1A42:03

SubIndex 003

3. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6020:0B, 1

1A42:04

SubIndex 004

4. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x0000:00, 2

1A42:05

SubIndex 005

5. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x05 (Sample))

UINT32

RO

0x6020:0E, 1

1A42:06

SubIndex 006

6. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x06 (Sample))

UINT32

RO

0x6020:0F, 1

1A42:07

SubIndex 007

7. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x07 (Sample))

UINT32

RO

0x6020:10, 1

1A42:08

SubIndex 008

8. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x08 (Sample))

UINT32

RO

0x0000:00, 16

1A42:09

SubIndex 009

9. PDO Mapping entry (object 0x6020 (AI Acc Inputs), entry 0x13 (Value (Real32)))

UINT32

RO

0x6020:13, 32

Index 1A43 AI Acc Z TxPDO-Map Input Legacy Int

Index (hex)

Name

Meaning

Data type

Flags

Default

1A43:0

AI Acc Z TxPDO-Map Input Legacy Int

PDO Mapping TxPDO 68

UINT8

RO

0x09 (9dec)

1A43:01

SubIndex 001

1. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x01 (Sample))

UINT32

RO

0x0000:00, 8

1A43:02

SubIndex 002

2. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x02 (Sample))

UINT32

RO

0x6020:09, 2

1A43:03

SubIndex 003

3. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x03 (Sample))

UINT32

RO

0x6020:0B, 1

1A43:04

SubIndex 004

4. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x04 (Sample))

UINT32

RO

0x0000:00, 2

1A43:05

SubIndex 005

5. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x05 (Sample))

UINT32

RO

0x6020:0E, 1

1A43:06

SubIndex 006

6. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x06 (Sample))

UINT32

RO

0x6020:0F, 1

1A43:07

SubIndex 007

7. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x07 (Sample))

UINT32

RO

0x6020:10, 1

1A43:08

SubIndex 008

8. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x08 (Sample))

UINT32

RO

0x0000:00, 16

1A43:09

SubIndex 009

9. PDO Mapping entry (object 0x6020 (AI Acc Inputs), entry 0x12 (Value))

UINT32

RO

0x6020:12, 32

Index 1A44 AI Acc Z TxPDO-Map Samples 1 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A44:0

AI Acc Z TxPDO-Map Samples 1 (Real32)

PDO Mapping TxPDO 69

UINT8

RO

0x01 (1dec)

1A44:01

SubIndex 001

1. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6023:01, 32

Index 1A45 AI Acc Z TxPDO-Map Samples 1

Index (hex)

Name

Meaning

Data type

Flags

Default

1A45:0

AI Acc Z TxPDO-Map Samples 1

PDO Mapping TxPDO 70

UINT8

RO

0x01 (1dec)

1A45:01

SubIndex 001

1. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x01 (Sample))

UINT32

RO

0x6021:01, 32

Index 1A46 AI Acc Z TxPDO-Map Samples 2 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A46:0

AI Acc Z TxPDO-Map Samples 2 (Real32)

PDO Mapping TxPDO 71

UINT8

RO

0x02 (2dec)

1A46:01

SubIndex 001

1. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6023:01, 32

1A46:02

SubIndex 002

2. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6023:02, 32

Index 1A47 AI Acc Z TxPDO-Map Samples 2

Index (hex)

Name

Meaning

Data type

Flags

Default

1A47:0

AI Acc Z TxPDO-Map Samples 2

PDO Mapping TxPDO 72

UINT8

RO

0x02 (2dec)

1A47:01

SubIndex 001

1. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x01 (Sample))

UINT32

RO

0x6021:01, 32

1A47:02

SubIndex 002

2. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x02 (Sample))

UINT32

RO

0x6021:02, 32

Index 1A48 AI Acc Z TxPDO-Map Samples 4 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A48:0

AI Acc Z TxPDO-Map Samples 4 (Real32)

PDO Mapping TxPDO 73

UINT8

RO

0x04 (4dec)

1A48:01

SubIndex 001

1. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6023:01, 32

1A48:02

SubIndex 002

2. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6023:02, 32

1A48:03

SubIndex 003

3. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6023:03, 32

1A48:04

SubIndex 004

4. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6023:04, 32

Index 1A49 AI Acc Z TxPDO-Map Samples 4

Index (hex)

Name

Meaning

Data type

Flags

Default

1A49:0

AI Acc Z TxPDO-Map Samples 4

PDO Mapping TxPDO 74

UINT8

RO

0x04 (4dec)

1A49:01

SubIndex 001

1. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x01 (Sample))

UINT32

RO

0x6021:01, 32

1A49:02

SubIndex 002

2. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x02 (Sample))

UINT32

RO

0x6021:02, 32

1A49:03

SubIndex 003

3. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x03 (Sample))

UINT32

RO

0x6021:03, 32

1A49:04

SubIndex 004

4. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x04 (Sample))

UINT32

RO

0x6021:04, 32

Index 1A4A AI Acc Z TxPDO-Map Samples 8 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A4A:0

AI Acc Z TxPDO-Map Samples 8 (Real32)

PDO Mapping TxPDO 75

UINT8

RO

0x08 (8dec)

1A4A:01

SubIndex 001

1. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6023:01, 32

1A4A:02

SubIndex 002

2. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6023:02, 32

1A4A:03

SubIndex 003

3. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6023:03, 32

1A4A:04

SubIndex 004

4. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6023:04, 32

1A4A:05

SubIndex 005

5. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x05 (Sample))

UINT32

RO

0x6023:05, 32

1A4A:06

SubIndex 006

6. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x06 (Sample))

UINT32

RO

0x6023:06, 32

1A4A:07

SubIndex 007

7. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x07 (Sample))

UINT32

RO

0x6023:07, 32

1A4A:08

SubIndex 008

8. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x08 (Sample))

UINT32

RO

0x6023:08, 32

Index 1A4B AI Acc Z TxPDO-Map Samples 8

Index (hex)

Name

Meaning

Data type

Flags

Default

1A4B:0

AI Acc Z TxPDO-Map Samples 8

PDO Mapping TxPDO 76

UINT8

RO

0x08 (8dec)

1A4B:01

SubIndex 001

1. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x01 (Sample))

UINT32

RO

0x6021:01, 32

1A4B:02

SubIndex 002

2. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x02 (Sample))

UINT32

RO

0x6021:02, 32

1A4B:03

SubIndex 003

3. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x03 (Sample))

UINT32

RO

0x6021:03, 32

1A4B:04

SubIndex 004

4. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x04 (Sample))

UINT32

RO

0x6021:04, 32

1A4B:05

SubIndex 005

5. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x05 (Sample))

UINT32

RO

0x6021:05, 32

1A4B:06

SubIndex 006

6. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x06 (Sample))

UINT32

RO

0x6021:06, 32

1A4B:07

SubIndex 007

7. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x07 (Sample))

UINT32

RO

0x6021:07, 32

1A4B:08

SubIndex 008

8. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x08 (Sample))

UINT32

RO

0x6021:08, 32

Index 1A4C AI Acc Z TxPDO-Map Samples 10 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A4C:0

AI Acc Z TxPDO-Map Samples 10 (Real32)

PDO Mapping TxPDO 77

UINT8

RO

0x0A (10dec)

1A4C:01

SubIndex 001

1. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6023:01, 32

1A4C:02

SubIndex 002

2. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6023:02, 32

1A4C:03

SubIndex 003

3. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6023:03, 32

1A4C:04

SubIndex 004

4. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6023:04, 32

1A4C:05

SubIndex 005

5. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x05 (Sample))

UINT32

RO

0x6023:05, 32

1A4C:06

SubIndex 006

6. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x06 (Sample))

UINT32

RO

0x6023:06, 32

1A4C:07

SubIndex 007

7. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x07 (Sample))

UINT32

RO

0x6023:07, 32

1A4C:08

SubIndex 008

8. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x08 (Sample))

UINT32

RO

0x6023:08, 32

1A4C:09

SubIndex 009

9. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x09 (Sample))

UINT32

RO

0x6023:09, 32

1A4C:0A

SubIndex 010

10. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x0A (Sample))

UINT32

RO

0x6023:0A, 32

Index 1A4D AI Acc Z TxPDO-Map Samples 10

Index (hex)

Name

Meaning

Data type

Flags

Default

1A4D:0

AI Acc Z TxPDO-Map Samples 10

PDO Mapping TxPDO 78

UINT8

RO

0x0A (10dec)

1A4D:01

SubIndex 001

1. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x01 (Sample))

UINT32

RO

0x6021:01, 32

1A4D:02

SubIndex 002

2. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x02 (Sample))

UINT32

RO

0x6021:02, 32

1A4D:03

SubIndex 003

3. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x03 (Sample))

UINT32

RO

0x6021:03, 32

1A4D:04

SubIndex 004

4. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x04 (Sample))

UINT32

RO

0x6021:04, 32

1A4D:05

SubIndex 005

5. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x05 (Sample))

UINT32

RO

0x6021:05, 32

1A4D:06

SubIndex 006

6. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x06 (Sample))

UINT32

RO

0x6021:06, 32

1A4D:07

SubIndex 007

7. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x07 (Sample))

UINT32

RO

0x6021:07, 32

1A4D:08

SubIndex 008

8. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x08 (Sample))

UINT32

RO

0x6021:08, 32

1A4D:09

SubIndex 009

9. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x09 (Sample))

UINT32

RO

0x6021:09, 32

1A4D:0A

SubIndex 010

10. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x0A (Sample))

UINT32

RO

0x6021:0A, 32

Index 1A4E AI Acc Z TxPDO-Map Samples 16 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A4E:0

AI Acc Z TxPDO-Map Samples 16 (Real32)

PDO Mapping TxPDO 79

UINT8

RO

0x10 (16dec)

1A4E:01

SubIndex 001

1. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6023:01, 32

1A4E:02

SubIndex 002

2. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6023:02, 32

1A4E:03

SubIndex 003

3. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6023:03, 32

1A4E:04

SubIndex 004

4. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6023:04, 32

1A4E:05

SubIndex 005

5. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x05 (Sample))

UINT32

RO

0x6023:05, 32

1A4E:06

SubIndex 006

6. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x06 (Sample))

UINT32

RO

0x6023:06, 32

1A4E:07

SubIndex 007

7. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x07 (Sample))

UINT32

RO

0x6023:07, 32

1A4E:08

SubIndex 008

8. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x08 (Sample))

UINT32

RO

0x6023:08, 32

1A4E:09

SubIndex 009

9. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x09 (Sample))

UINT32

RO

0x6023:09, 32

1A4E:0A

SubIndex 010

10. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x0A (Sample))

UINT32

RO

0x6023:0A, 32

1A4E:0B

SubIndex 011

11. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x0B (Sample))

UINT32

RO

0x6023:0B, 32

1A4E:0C

SubIndex 012

12. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x0C (Sample))

UINT32

RO

0x6023:0C, 32

1A4E:0D

SubIndex 013

13. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x0D (Sample))

UINT32

RO

0x6023:0D, 32

1A4E:0E

SubIndex 014

14. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x0E (Sample))

UINT32

RO

0x6023:0E, 32

1A4E:0F

SubIndex 015

15. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x0F (Sample))

UINT32

RO

0x6023:0F, 32

1A4E:10

SubIndex 016

16. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x10 (Sample))

UINT32

RO

0x6023:10, 32

Index 1A4F AI Acc Z TxPDO-Map Samples 16

Index (hex)

Name

Meaning

Data type

Flags

Default

1A4F:0

AI Acc Z TxPDO-Map Samples 16

PDO Mapping TxPDO 80

UINT8

RO

0x10 (16dec)

1A4F:01

SubIndex 001

1. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x01 (Sample))

UINT32

RO

0x6021:01, 32

1A4F:02

SubIndex 002

2. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x02 (Sample))

UINT32

RO

0x6021:02, 32

1A4F:03

SubIndex 003

3. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x03 (Sample))

UINT32

RO

0x6021:03, 32

1A4F:04

SubIndex 004

4. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x04 (Sample))

UINT32

RO

0x6021:04, 32

1A4F:05

SubIndex 005

5. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x05 (Sample))

UINT32

RO

0x6021:05, 32

1A4F:06

SubIndex 006

6. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x06 (Sample))

UINT32

RO

0x6021:06, 32

1A4F:07

SubIndex 007

7. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x07 (Sample))

UINT32

RO

0x6021:07, 32

1A4F:08

SubIndex 008

8. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x08 (Sample))

UINT32

RO

0x6021:08, 32

1A4F:09

SubIndex 009

9. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x09 (Sample))

UINT32

RO

0x6021:09, 32

1A4F:0A

SubIndex 010

10. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x0A (Sample))

UINT32

RO

0x6021:0A, 32

1A4F:0B

SubIndex 011

11. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x0B (Sample))

UINT32

RO

0x6021:0B, 32

1A4F:0C

SubIndex 012

12. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x0C (Sample))

UINT32

RO

0x6021:0C, 32

1A4F:0D

SubIndex 013

13. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x0D (Sample))

UINT32

RO

0x6021:0D, 32

1A4F:0E

SubIndex 014

14. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x0E (Sample))

UINT32

RO

0x6021:0E, 32

1A4F:0F

SubIndex 015

15. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x0F (Sample))

UINT32

RO

0x6021:0F, 32

1A4F:10

SubIndex 016

16. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x10 (Sample))

UINT32

RO

0x6021:10, 32

Index 1A50 AI Acc Z TxPDO-Map Samples 20 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A50:0

AI Acc Z TxPDO-Map Samples 20 (Real32)

PDO Mapping TxPDO 81

UINT8

RO

0x14 (20dec)

1A50:01

SubIndex 001

1. PDO Mapping entry (8 bits align)

UINT32

RO

0x6023:01, 32

1A50:02

SubIndex 002

2. PDO Mapping entry (object 0x6050 (AI Gyro Inputs), entry 0x09 (Self test status))

UINT32

RO

0x6023:02, 32

1A50:03

SubIndex 003

3. PDO Mapping entry (object 0x6050 (AI Gyro Inputs), entry 0x0B (Slope detected))

UINT32

RO

0x6023:03, 32

1A50:04

SubIndex 004

4. PDO Mapping entry (3 bits align)

UINT32

RO

0x6023:04, 32

1A50:05

SubIndex 005

5. PDO Mapping entry (object 0x6050 (AI Gyro Inputs), entry 0x0F (TxPDO State))

UINT32

RO

0x6023:05, 32

1A50:06

SubIndex 006

6. PDO Mapping entry (object 0x6050 (AI Gyro Inputs), entry 0x10 (TxPDO Toggle))

UINT32

RO

0x6023:06, 32

1A50:07

SubIndex 007

7. PDO Mapping entry (16 bits align)

UINT32

RO

0x6023:07, 32

1A50:08

SubIndex 008

8. PDO Mapping entry (object 0x6050 (AI Gyro Inputs), entry 0x13 (Value (Real32)))

UINT32

RO

0x6023:08, 32

1A50:09

SubIndex 009

9. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x09 (Sample))

UINT32

RO

0x6023:09, 32

1A50:0A

SubIndex 010

10. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x0A (Sample))

UINT32

RO

0x6023:0A, 32

1A50:0B

SubIndex 011

11. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x0B (Sample))

UINT32

RO

0x6023:0B, 32

1A50:0C

SubIndex 012

12. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x0C (Sample))

UINT32

RO

0x6023:0C, 32

1A50:0D

SubIndex 013

13. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x0D (Sample))

UINT32

RO

0x6023:0D, 32

1A50:0E

SubIndex 014

14. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x0E (Sample))

UINT32

RO

0x6023:0E, 32

1A50:0F

SubIndex 015

15. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x0F (Sample))

UINT32

RO

0x6023:0F, 32

1A50:10

SubIndex 016

16. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x10 (Sample))

UINT32

RO

0x6023:10, 32

1A50:11

SubIndex 017

17. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x11 (Sample))

UINT32

RO

0x6023:11, 32

1A50:12

SubIndex 018

18. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x12 (Sample))

UINT32

RO

0x6023:12, 32

1A50:13

SubIndex 019

19. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x13 (Sample))

UINT32

RO

0x6023:13, 32

1A50:14

SubIndex 020

20. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x14 (Sample))

UINT32

RO

0x6023:14, 32

Index 1A51 AI Acc Z TxPDO-Map Samples 20

Index (hex)

Name

Meaning

Data type

Flags

Default

1A51:0

AI Acc Z TxPDO-Map Samples 20

PDO Mapping TxPDO 82

UINT8

RO

0x14 (20dec)

1A51:01

SubIndex 001

1. PDO Mapping entry (8 bits align)

UINT32

RO

0x6021:01, 32

1A51:02

SubIndex 002

2. PDO Mapping entry (object 0x6050 (AI Gyro Inputs), entry 0x09 (Self test status))

UINT32

RO

0x6021:02, 32

1A51:03

SubIndex 003

3. PDO Mapping entry (object 0x6050 (AI Gyro Inputs), entry 0x0B (Slope detected))

UINT32

RO

0x6021:03, 32

1A51:04

SubIndex 004

4. PDO Mapping entry (3 bits align)

UINT32

RO

0x6021:04, 32

1A51:05

SubIndex 005

5. PDO Mapping entry (object 0x6050 (AI Gyro Inputs), entry 0x0F (TxPDO State))

UINT32

RO

0x6021:05, 32

1A51:06

SubIndex 006

6. PDO Mapping entry (object 0x6050 (AI Gyro Inputs), entry 0x10 (TxPDO Toggle))

UINT32

RO

0x6021:06, 32

1A51:07

SubIndex 007

7. PDO Mapping entry (16 bits align)

UINT32

RO

0x6021:07, 32

1A51:08

SubIndex 008

8. PDO Mapping entry (object 0x6050 (AI Gyro Inputs), entry 0x12 (Value))

UINT32

RO

0x6021:08, 32

1A51:09

SubIndex 009

9. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x09 (Sample))

UINT32

RO

0x6021:09, 32

1A51:0A

SubIndex 010

10. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x0A (Sample))

UINT32

RO

0x6021:0A, 32

1A51:0B

SubIndex 011

11. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x0B (Sample))

UINT32

RO

0x6021:0B, 32

1A51:0C

SubIndex 012

12. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x0C (Sample))

UINT32

RO

0x6021:0C, 32

1A51:0D

SubIndex 013

13. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x0D (Sample))

UINT32

RO

0x6021:0D, 32

1A51:0E

SubIndex 014

14. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x0E (Sample))

UINT32

RO

0x6021:0E, 32

1A51:0F

SubIndex 015

15. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x0F (Sample))

UINT32

RO

0x6021:0F, 32

1A51:10

SubIndex 016

16. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x10 (Sample))

UINT32

RO

0x6021:10, 32

1A51:11

SubIndex 017

17. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x11 (Sample))

UINT32

RO

0x6021:11, 32

1A51:12

SubIndex 018

18. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x12 (Sample))

UINT32

RO

0x6021:12, 32

1A51:13

SubIndex 019

19. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x13 (Sample))

UINT32

RO

0x6021:13, 32

1A51:14

SubIndex 020

20. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x14 (Sample))

UINT32

RO

0x6021:14, 32

Index 1A52 AI Acc Z TxPDO-Map Samples 40 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A52:0

AI Acc Z TxPDO-Map Samples 40 (Real32)

PDO Mapping TxPDO 83

UINT8

RO

0x28 (40dec)

1A52:01

SubIndex 001

1. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6023:01, 32

1A52:02

SubIndex 002

2. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6023:02, 32

1A52:03

SubIndex 003

3. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6023:03, 32

1A52:04

SubIndex 004

4. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6023:04, 32

1A52:05

SubIndex 005

5. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x05 (Sample))

UINT32

RO

0x6023:05, 32

1A52:06

SubIndex 006

6. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x06 (Sample))

UINT32

RO

0x6023:06, 32

1A52:07

SubIndex 007

7. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x07 (Sample))

UINT32

RO

0x6023:07, 32

1A52:08

SubIndex 008

8. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x08 (Sample))

UINT32

RO

0x6023:08, 32

1A52:09

SubIndex 009

9. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x09 (Sample))

UINT32

RO

0x6023:09, 32

1A52:0A

SubIndex 010

10. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x0A (Sample))

UINT32

RO

0x6023:0A, 32

1A52:0B

SubIndex 011

11. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x0B (Sample))

UINT32

RO

0x6023:0B, 32

1A52:0C

SubIndex 012

12. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x0C (Sample))

UINT32

RO

0x6023:0C, 32

1A52:0D

SubIndex 013

13. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x0D (Sample))

UINT32

RO

0x6023:0D, 32

1A52:0E

SubIndex 014

14. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x0E (Sample))

UINT32

RO

0x6023:0E, 32

1A52:0F

SubIndex 015

15. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x0F (Sample))

UINT32

RO

0x6023:0F, 32

1A52:10

SubIndex 016

16. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x10 (Sample))

UINT32

RO

0x6023:10, 32

1A52:11

SubIndex 017

17. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x11 (Sample))

UINT32

RO

0x6023:11, 32

1A52:12

SubIndex 018

18. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x12 (Sample))

UINT32

RO

0x6023:12, 32

1A52:13

SubIndex 019

19. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x13 (Sample))

UINT32

RO

0x6023:13, 32

1A52:14

SubIndex 020

20. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x14 (Sample))

UINT32

RO

0x6023:14, 32

1A52:15

SubIndex 021

21. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x15 (Sample))

UINT32

RO

0x6023:15, 32

1A52:16

SubIndex 022

22. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x16 (Sample))

UINT32

RO

0x6023:16, 32

1A52:17

SubIndex 023

23. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x17 (Sample))

UINT32

RO

0x6023:17, 32

1A52:18

SubIndex 024

24. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x18 (Sample))

UINT32

RO

0x6023:18, 32

1A52:19

SubIndex 025

25. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x19 (Sample))

UINT32

RO

0x6023:19, 32

1A52:1A

SubIndex 026

26. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x1A (Sample))

UINT32

RO

0x6023:1A, 32

1A52:1B

SubIndex 027

27. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x1B (Sample))

UINT32

RO

0x6023:1B, 32

1A52:1C

SubIndex 028

28. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x1C (Sample))

UINT32

RO

0x6023:1C, 32

1A52:1D

SubIndex 029

29. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x1D (Sample))

UINT32

RO

0x6023:1D, 32

Index (hex)

Name

Meaning

Data type

Flags

Default

1A52:1E

SubIndex 030

30. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x1E (Sample))

UINT32

RO

0x6023:1E, 32

1A52:1F

SubIndex 031

31. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x1F (Sample))

UINT32

RO

0x6023:1F, 32

1A52:20

SubIndex 032

32. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x20 (Sample))

UINT32

RO

0x6023:20, 32

1A52:21

SubIndex 033

33. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x21 (Sample))

UINT32

RO

0x6023:21, 32

1A52:22

SubIndex 034

34. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x22 (Sample))

UINT32

RO

0x6023:22, 32

1A52:23

SubIndex 035

35. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x23 (Sample))

UINT32

RO

0x6023:23, 32

1A52:24

SubIndex 036

36. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x24 (Sample))

UINT32

RO

0x6023:24, 32

1A52:25

SubIndex 037

37. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x25 (Sample))

UINT32

RO

0x6023:25, 32

1A52:26

SubIndex 038

38. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x26 (Sample))

UINT32

RO

0x6023:26, 32

1A52:27

SubIndex 039

39. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x27 (Sample))

UINT32

RO

0x6023:27, 32

1A52:28

SubIndex 040

40. PDO Mapping entry (object 0x6023 (AI Acc Samples (Real32)), entry 0x28 (Sample))

UINT32

RO

0x6023:28, 32

Index 1A53 AI Acc Z TxPDO-Map Samples 40

Index (hex)

Name

Meaning

Data type

Flags

Default

1A53:0

AI Acc Z TxPDO-Map Samples 40

PDO Mapping TxPDO 84

UINT8

RO

0x28 (40dec)

1A53:01

SubIndex 001

1. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x01 (Sample))

UINT32

RO

0x6021:01, 32

1A53:02

SubIndex 002

2. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x02 (Sample))

UINT32

RO

0x6021:02, 32

1A53:03

SubIndex 003

3. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x03 (Sample))

UINT32

RO

0x6021:03, 32

1A53:04

SubIndex 004

4. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x04 (Sample))

UINT32

RO

0x6021:04, 32

1A53:05

SubIndex 005

5. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x05 (Sample))

UINT32

RO

0x6021:05, 32

1A53:06

SubIndex 006

6. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x06 (Sample))

UINT32

RO

0x6021:06, 32

1A53:07

SubIndex 007

7. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x07 (Sample))

UINT32

RO

0x6021:07, 32

1A53:08

SubIndex 008

8. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x08 (Sample))

UINT32

RO

0x6021:08, 32

1A53:09

SubIndex 009

9. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x09 (Sample))

UINT32

RO

0x6021:09, 32

1A53:0A

SubIndex 010

10. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x0A (Sample))

UINT32

RO

0x6021:0A, 32

1A53:0B

SubIndex 011

11. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x0B (Sample))

UINT32

RO

0x6021:0B, 32

1A53:0C

SubIndex 012

12. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x0C (Sample))

UINT32

RO

0x6021:0C, 32

1A53:0D

SubIndex 013

13. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x0D (Sample))

UINT32

RO

0x6021:0D, 32

Index (hex)

Name

Meaning

Data type

Flags

Default

1A53:0E

SubIndex 014

14. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x0E (Sample))

UINT32

RO

0x6021:0E, 32

1A53:0F

SubIndex 015

15. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x0F (Sample))

UINT32

RO

0x6021:0F, 32

1A53:10

SubIndex 016

16. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x10 (Sample))

UINT32

RO

0x6021:10, 32

1A53:11

SubIndex 017

17. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x11 (Sample))

UINT32

RO

0x6021:11, 32

1A53:12

SubIndex 018

18. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x12 (Sample))

UINT32

RO

0x6021:12, 32

1A53:13

SubIndex 019

19. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x13 (Sample))

UINT32

RO

0x6021:13, 32

1A53:14

SubIndex 020

20. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x14 (Sample))

UINT32

RO

0x6021:14, 32

1A53:15

SubIndex 021

21. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x15 (Sample))

UINT32

RO

0x6021:15, 32

1A53:16

SubIndex 022

22. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x16 (Sample))

UINT32

RO

0x6021:16, 32

1A53:17

SubIndex 023

23. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x17 (Sample))

UINT32

RO

0x6021:17, 32

1A53:18

SubIndex 024

24. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x18 (Sample))

UINT32

RO

0x6021:18, 32

1A53:19

SubIndex 025

25. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x19 (Sample))

UINT32

RO

0x6021:19, 32

1A53:1A

SubIndex 026

26. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x1A (Sample))

UINT32

RO

0x6021:1A, 32

1A53:1B

SubIndex 027

27. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x1B (Sample))

UINT32

RO

0x6021:1B, 32

1A53:1C

SubIndex 028

28. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x1C (Sample))

UINT32

RO

0x6021:1C, 32

1A53:1D

SubIndex 029

29. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x1D (Sample))

UINT32

RO

0x6021:1D, 32

1A53:1E

SubIndex 030

30. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x1E (Sample))

UINT32

RO

0x6021:1E, 32

1A53:1F

SubIndex 031

31. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x1F (Sample))

UINT32

RO

0x6021:1F, 32

1A53:20

SubIndex 032

32. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x20 (Sample))

UINT32

RO

0x6021:20, 32

1A53:21

SubIndex 033

33. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x21 (Sample))

UINT32

RO

0x6021:21, 32

1A53:22

SubIndex 034

34. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x22 (Sample))

UINT32

RO

0x6021:22, 32

1A53:23

SubIndex 035

35. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x23 (Sample))

UINT32

RO

0x6021:23, 32

1A53:24

SubIndex 036

36. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x24 (Sample))

UINT32

RO

0x6021:24, 32

1A53:25

SubIndex 037

37. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x25 (Sample))

UINT32

RO

0x6021:25, 32

1A53:26

SubIndex 038

38. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x26 (Sample))

UINT32

RO

0x6021:26, 32

1A53:27

SubIndex 039

39. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x27 (Sample))

UINT32

RO

0x6021:27, 32

1A53:28

SubIndex 040

40. PDO Mapping entry (object 0x6021 (AI Acc Samples), entry 0x28 (Sample))

UINT32

RO

0x6021:28, 32

Index 1A60 AI Gyro X TxPDO-Map Status

Index (hex)

Name

Meaning

Data type

Flags

Default

1A60:0

AI Gyro X TxPDO-Map Status

PDO Mapping TxPDO 97

UINT8

RO

0x08 (8dec)

1A60:01

SubIndex 001

1. PDO Mapping entry (14 bits align)

UINT32

RO

0x0000:00, 8

1A60:02

SubIndex 002

2. PDO Mapping entry (object 0x6060 (AI Temp Inputs Ch.1), entry 0x0F (TxPDO State))

UINT32

RO

0x6030:09, 2

1A60:03

SubIndex 003

3. PDO Mapping entry (object 0x6060 (AI Temp Inputs Ch.1), entry 0x10 (TxPDO Toggle))

UINT32

RO

0x6030:0B, 1

1A60:04

SubIndex 004

4. PDO Mapping entry (16 bits align)

UINT32

RO

0x0000:00, 2

1A60:05

SubIndex 005

5. PDO Mapping entry (object 0x6060 (AI Temp Inputs Ch.1), entry 0x13 (Value (Real32)))

UINT32

RO

0x6030:0E, 1

1A60:06

SubIndex 006

6. PDO Mapping entry (object 0x6030 (AI Gyro Inputs), entry 0x10 (TxPDO Toggle))

UINT32

RO

0x6030:0F, 1

1A60:07

SubIndex 007

7. PDO Mapping entry (16 bits align)

UINT32

RO

0x6030:10, 1

1A60:08

SubIndex 008

8. PDO Mapping entry (16 bits align)

UINT32

RO

0x0000:00, 16

Index 1A61 AI Gyro X TxPDO-Map Input Cycle Counter

Index (hex)

Name

Meaning

Data type

Flags

Default

1A61:0

AI Gyro X TxPDO-Map Input Cycle Counter

PDO Mapping TxPDO 98

UINT8

RO

0x01 (1dec)

1A61:01

SubIndex 001

1. PDO Mapping entry (14 bits align)

UINT32

RO

0x6030:14, 16

Index 1A62 AI Gyro X TxPDO-Map Inputs Legacy Real

Index (hex)

Name

Meaning

Data type

Flags

Default

1A62:0

AI Gyro X TxPDO-Map Inputs Legacy Real

PDO Mapping TxPDO 99

UINT8

RO

0x09 (9dec)

1A62:01

SubIndex 001

1. PDO Mapping entry (8 bits align)

UINT32

RO

0x0000:00, 8

1A62:02

SubIndex 002

2. PDO Mapping entry (object 0x6030 (AI Gyro Inputs), entry 0x09 (Self test status))

UINT32

RO

0x6030:09, 2

1A62:03

SubIndex 003

3. PDO Mapping entry (object 0x6030 (AI Gyro Inputs), entry 0x0B (Slope detected))

UINT32

RO

0x6030:0B, 1

1A62:04

SubIndex 004

4. PDO Mapping entry (3 bits align)

UINT32

RO

0x0000:00, 2

1A62:05

SubIndex 005

5. PDO Mapping entry (object 0x6030 (AI Gyro Inputs), entry 0x0F (TxPDO State))

UINT32

RO

0x6030:0E, 1

1A62:06

SubIndex 006

6. PDO Mapping entry (object 0x6030 (AI Gyro Inputs), entry 0x10 (TxPDO Toggle))

UINT32

RO

0x6030:0F, 1

1A62:07

SubIndex 007

7. PDO Mapping entry (16 bits align)

UINT32

RO

0x6030:10, 1

1A62:08

SubIndex 008

8. PDO Mapping entry (object 0x6030 (AI Gyro Inputs), entry 0x13 (Value (Real32)))

UINT32

RO

0x0000:00, 16

1A62:09

SubIndex 009

9. PDO Mapping entry (object 0x6030 (AI Gyro Inputs), entry 0x13 (Value (Real32)))

UINT32

RO

0x6030:13, 32

Index 1A63 AI Gyro X TxPDO-Map Inputs Legacy Int

Index (hex)

Name

Meaning

Data type

Flags

Default

1A63:0

AI Gyro X TxPDO-Map Inputs Legacy Int

PDO Mapping TxPDO 100

UINT8

RO

0x09 (9dec)

1A63:01

SubIndex 001

1. PDO Mapping entry (8 bits align)

UINT32

RO

0x0000:00, 8

1A63:02

SubIndex 002

2. PDO Mapping entry (object 0x6030 (AI Gyro Inputs), entry 0x09 (Self test status))

UINT32

RO

0x6030:09, 2

1A63:03

SubIndex 003

3. PDO Mapping entry (object 0x6030 (AI Gyro Inputs), entry 0x0B (Slope detected))

UINT32

RO

0x6030:0B, 1

1A63:04

SubIndex 004

4. PDO Mapping entry (3 bits align)

UINT32

RO

0x0000:00, 2

1A63:05

SubIndex 005

5. PDO Mapping entry (object 0x6030 (AI Gyro Inputs), entry 0x0F (TxPDO State))

UINT32

RO

0x6030:0E, 1

1A63:06

SubIndex 006

6. PDO Mapping entry (object 0x6030 (AI Gyro Inputs), entry 0x10 (TxPDO Toggle))

UINT32

RO

0x6030:0F, 1

1A63:07

SubIndex 007

7. PDO Mapping entry (16 bits align)

UINT32

RO

0x6030:10, 1

1A63:08

SubIndex 008

8. PDO Mapping entry (object 0x6030 (AI Gyro Inputs), entry 0x12 (Value))

UINT32

RO

0x0000:00, 16

1A63:09

SubIndex 009

9. PDO Mapping entry (object 0x6030 (AI Gyro Inputs), entry 0x12 (Value))

UINT32

RO

0x6030:12, 32

Index 1A64 AI Gyro X TxPDO-Map Samples 1 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A64:0

AI Gyro X TxPDO-Map Samples 1 (Real32)

PDO Mapping TxPDO 101

UINT8

RO

0x01 (1dec)

1A64:01

SubIndex 001

1. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6033:01, 32

Index 1A65 AI Gyro X TxPDO-Map Samples 1

Index (hex)

Name

Meaning

Data type

Flags

Default

1A65:0

AI Gyro X TxPDO-Map Samples 1

PDO Mapping TxPDO 102

UINT8

RO

0x01 (1dec)

1A65:01

SubIndex 001

1. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x01 (Sample))

UINT32

RO

0x6031:01, 32

Index 1A66 AI Gyro X TxPDO-Map Samples 2 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A66:0

AI Gyro X TxPDO-Map Samples 2 (Real32)

PDO Mapping TxPDO 103

UINT8

RO

0x02 (2dec)

1A66:01

SubIndex 001

1. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6033:01, 32

1A66:02

SubIndex 002

2. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6033:02, 32

Index 1A67 AI Gyro X TxPDO-Map Samples 2

Index (hex)

Name

Meaning

Data type

Flags

Default

1A67:0

AI Gyro X TxPDO-Map Samples 2

PDO Mapping TxPDO 104

UINT8

RO

0x02 (2dec)

1A67:01

SubIndex 001

1. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x01 (Sample))

UINT32

RO

0x6031:01, 32

1A67:02

SubIndex 002

2. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x02 (Sample))

UINT32

RO

0x6031:02, 32

Index 1A68 AI Gyro X TxPDO-Map Samples 4 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A68:0

AI Gyro X TxPDO-Map Samples 4 (Real32)

PDO Mapping TxPDO 105

UINT8

RO

0x04 (4dec)

1A68:01

SubIndex 001

1. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6033:01, 32

1A68:02

SubIndex 002

2. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6033:02, 32

1A68:03

SubIndex 003

3. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6033:03, 32

1A68:04

SubIndex 004

4. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6033:04, 32

Index 1A69 AI Gyro X TxPDO-Map Samples 4

Index (hex)

Name

Meaning

Data type

Flags

Default

1A69:0

AI Gyro X TxPDO-Map Samples 4

PDO Mapping TxPDO 106

UINT8

RO

0x04 (4dec)

1A69:01

SubIndex 001

1. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x01 (Sample))

UINT32

RO

0x6031:01, 32

1A69:02

SubIndex 002

2. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x02 (Sample))

UINT32

RO

0x6031:02, 32

1A69:03

SubIndex 003

3. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x03 (Sample))

UINT32

RO

0x6031:03, 32

1A69:04

SubIndex 004

4. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x04 (Sample))

UINT32

RO

0x6031:04, 32

Index 1A6A AI Gyro X TxPDO-Map Samples 8 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A6A:0

AI Gyro X TxPDO-Map Samples 8 (Real32)

PDO Mapping TxPDO 107

UINT8

RO

0x08 (8dec)

1A6A:01

SubIndex 001

1. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6033:01, 32

1A6A:02

SubIndex 002

2. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6033:02, 32

1A6A:03

SubIndex 003

3. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6033:03, 32

1A6A:04

SubIndex 004

4. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6033:04, 32

1A6A:05

SubIndex 005

5. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x05 (Sample))

UINT32

RO

0x6033:05, 32

1A6A:06

SubIndex 006

6. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x06 (Sample))

UINT32

RO

0x6033:06, 32

1A6A:07

SubIndex 007

7. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x07 (Sample))

UINT32

RO

0x6033:07, 32

1A6A:08

SubIndex 008

8. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x08 (Sample))

UINT32

RO

0x6033:08, 32

Index 1A6B AI Gyro X TxPDO-Map Samples 8

Index (hex)

Name

Meaning

Data type

Flags

Default

1A6B:0

AI Gyro X TxPDO-Map Samples 8

PDO Mapping TxPDO 108

UINT8

RO

0x08 (8dec)

1A6B:01

SubIndex 001

1. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x01 (Sample))

UINT32

RO

0x6031:01, 32

1A6B:02

SubIndex 002

2. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x02 (Sample))

UINT32

RO

0x6031:02, 32

1A6B:03

SubIndex 003

3. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x03 (Sample))

UINT32

RO

0x6031:03, 32

1A6B:04

SubIndex 004

4. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x04 (Sample))

UINT32

RO

0x6031:04, 32

1A6B:05

SubIndex 005

5. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x05 (Sample))

UINT32

RO

0x6031:05, 32

1A6B:06

SubIndex 006

6. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x06 (Sample))

UINT32

RO

0x6031:06, 32

1A6B:07

SubIndex 007

7. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x07 (Sample))

UINT32

RO

0x6031:07, 32

1A6B:08

SubIndex 008

8. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x08 (Sample))

UINT32

RO

0x6031:08, 32

Index 1A6C AI Gyro X TxPDO-Map Samples 10 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A6C:0

AI Gyro X TxPDO-Map Samples 10 (Real32)

PDO Mapping TxPDO 109

UINT8

RO

0x0A (10dec)

1A6C:01

SubIndex 001

1. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6033:01, 32

1A6C:02

SubIndex 002

2. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6033:02, 32

1A6C:03

SubIndex 003

3. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6033:03, 32

1A6C:04

SubIndex 004

4. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6033:04, 32

1A6C:05

SubIndex 005

5. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x05 (Sample))

UINT32

RO

0x6033:05, 32

1A6C:06

SubIndex 006

6. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x06 (Sample))

UINT32

RO

0x6033:06, 32

1A6C:07

SubIndex 007

7. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x07 (Sample))

UINT32

RO

0x6033:07, 32

1A6C:08

SubIndex 008

8. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x08 (Sample))

UINT32

RO

0x6033:08, 32

1A6C:09

SubIndex 009

9. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x09 (Sample))

UINT32

RO

0x6033:09, 32

1A6C:0A

SubIndex 010

10. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x0A (Sample))

UINT32

RO

0x6033:0A, 32

Index 1A6D AI Gyro X TxPDO-Map Samples 10

Index (hex)

Name

Meaning

Data type

Flags

Default

1A6D:0

AI Gyro X TxPDO-Map Samples 10

PDO Mapping TxPDO 110

UINT8

RO

0x0A (10dec)

1A6D:01

SubIndex 001

1. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x01 (Sample))

UINT32

RO

0x6031:01, 32

1A6D:02

SubIndex 002

2. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x02 (Sample))

UINT32

RO

0x6031:02, 32

1A6D:03

SubIndex 003

3. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x03 (Sample))

UINT32

RO

0x6031:03, 32

1A6D:04

SubIndex 004

4. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x04 (Sample))

UINT32

RO

0x6031:04, 32

1A6D:05

SubIndex 005

5. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x05 (Sample))

UINT32

RO

0x6031:05, 32

1A6D:06

SubIndex 006

6. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x06 (Sample))

UINT32

RO

0x6031:06, 32

1A6D:07

SubIndex 007

7. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x07 (Sample))

UINT32

RO

0x6031:07, 32

1A6D:08

SubIndex 008

8. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x08 (Sample))

UINT32

RO

0x6031:08, 32

1A6D:09

SubIndex 009

9. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x09 (Sample))

UINT32

RO

0x6031:09, 32

1A6D:0A

SubIndex 010

10. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x0A (Sample))

UINT32

RO

0x6031:0A, 32

Index 1A6E AI Gyro X TxPDO-Map Samples 16 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A6E:0

AI Gyro X TxPDO-Map Samples 16 (Real32)

PDO Mapping TxPDO 111

UINT8

RO

0x10 (16dec)

1A6E:01

SubIndex 001

1. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6033:01, 32

1A6E:02

SubIndex 002

2. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6033:02, 32

1A6E:03

SubIndex 003

3. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6033:03, 32

1A6E:04

SubIndex 004

4. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6033:04, 32

1A6E:05

SubIndex 005

5. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x05 (Sample))

UINT32

RO

0x6033:05, 32

1A6E:06

SubIndex 006

6. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x06 (Sample))

UINT32

RO

0x6033:06, 32

1A6E:07

SubIndex 007

7. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x07 (Sample))

UINT32

RO

0x6033:07, 32

1A6E:08

SubIndex 008

8. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x08 (Sample))

UINT32

RO

0x6033:08, 32

1A6E:09

SubIndex 009

9. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x09 (Sample))

UINT32

RO

0x6033:09, 32

1A6E:0A

SubIndex 010

10. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x0A (Sample))

UINT32

RO

0x6033:0A, 32

1A6E:0B

SubIndex 011

11. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x0B (Sample))

UINT32

RO

0x6033:0B, 32

1A6E:0C

SubIndex 012

12. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x0C (Sample))

UINT32

RO

0x6033:0C, 32

1A6E:0D

SubIndex 013

13. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x0D (Sample))

UINT32

RO

0x6033:0D, 32

1A6E:0E

SubIndex 014

14. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x0E (Sample))

UINT32

RO

0x6033:0E, 32

1A6E:0F

SubIndex 015

15. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x0F (Sample))

UINT32

RO

0x6033:0F, 32

1A6E:10

SubIndex 016

16. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x10 (Sample))

UINT32

RO

0x6033:10, 32

Index 1A6F AI Gyro X TxPDO-Map Samples 16

Index (hex)

Name

Meaning

Data type

Flags

Default

1A6F:0

AI Gyro X TxPDO-Map Samples 16

PDO Mapping TxPDO 112

UINT8

RO

0x10 (16dec)

1A6F:01

SubIndex 001

1. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x01 (Sample))

UINT32

RO

0x6031:01, 32

1A6F:02

SubIndex 002

2. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x02 (Sample))

UINT32

RO

0x6031:02, 32

1A6F:03

SubIndex 003

3. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x03 (Sample))

UINT32

RO

0x6031:03, 32

1A6F:04

SubIndex 004

4. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x04 (Sample))

UINT32

RO

0x6031:04, 32

1A6F:05

SubIndex 005

5. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x05 (Sample))

UINT32

RO

0x6031:05, 32

1A6F:06

SubIndex 006

6. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x06 (Sample))

UINT32

RO

0x6031:06, 32

1A6F:07

SubIndex 007

7. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x07 (Sample))

UINT32

RO

0x6031:07, 32

1A6F:08

SubIndex 008

8. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x08 (Sample))

UINT32

RO

0x6031:08, 32

1A6F:09

SubIndex 009

9. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x09 (Sample))

UINT32

RO

0x6031:09, 32

1A6F:0A

SubIndex 010

10. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x0A (Sample))

UINT32

RO

0x6031:0A, 32

1A6F:0B

SubIndex 011

11. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x0B (Sample))

UINT32

RO

0x6031:0B, 32

1A6F:0C

SubIndex 012

12. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x0C (Sample))

UINT32

RO

0x6031:0C, 32

1A6F:0D

SubIndex 013

13. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x0D (Sample))

UINT32

RO

0x6031:0D, 32

1A6F:0E

SubIndex 014

14. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x0E (Sample))

UINT32

RO

0x6031:0E, 32

1A6F:0F

SubIndex 015

15. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x0F (Sample))

UINT32

RO

0x6031:0F, 32

1A6F:10

SubIndex 016

16. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x10 (Sample))

UINT32

RO

0x6031:10, 32

Index 1A70 AI Gyro X TxPDO-Map Samples 20 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A70:0

AI Gyro X TxPDO-Map Samples 20 (Real32)

PDO Mapping TxPDO 113

UINT8

RO

0x14 (20dec)

1A70:01

SubIndex 001

1. PDO Mapping entry (object 0x6070 (AI Acc Inputs), entry 0x11 (Sync Indicator))

UINT32

RO

0x6033:01, 32

1A70:02

SubIndex 002

2. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6033:02, 32

1A70:03

SubIndex 003

3. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6033:03, 32

1A70:04

SubIndex 004

4. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6033:04, 32

1A70:05

SubIndex 005

5. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x05 (Sample))

UINT32

RO

0x6033:05, 32

1A70:06

SubIndex 006

6. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x06 (Sample))

UINT32

RO

0x6033:06, 32

1A70:07

SubIndex 007

7. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x07 (Sample))

UINT32

RO

0x6033:07, 32

1A70:08

SubIndex 008

8. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x08 (Sample))

UINT32

RO

0x6033:08, 32

1A70:09

SubIndex 009

9. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x09 (Sample))

UINT32

RO

0x6033:09, 32

1A70:0A

SubIndex 010

10. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x0A (Sample))

UINT32

RO

0x6033:0A, 32

1A70:0B

SubIndex 011

11. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x0B (Sample))

UINT32

RO

0x6033:0B, 32

1A70:0C

SubIndex 012

12. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x0C (Sample))

UINT32

RO

0x6033:0C, 32

1A70:0D

SubIndex 013

13. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x0D (Sample))

UINT32

RO

0x6033:0D, 32

1A70:0E

SubIndex 014

14. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x0E (Sample))

UINT32

RO

0x6033:0E, 32

1A70:0F

SubIndex 015

15. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x0F (Sample))

UINT32

RO

0x6033:0F, 32

1A70:10

SubIndex 016

16. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x10 (Sample))

UINT32

RO

0x6033:10, 32

1A70:11

SubIndex 017

17. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x11 (Sample))

UINT32

RO

0x6033:11, 32

1A70:12

SubIndex 018

18. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x12 (Sample))

UINT32

RO

0x6033:12, 32

1A70:13

SubIndex 019

19. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x13 (Sample))

UINT32

RO

0x6033:13, 32

1A70:14

SubIndex 020

20. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x14 (Sample))

UINT32

RO

0x6033:14, 32

Index 1A71 AI Gyro X TxPDO-Map Samples 20

Index (hex)

Name

Meaning

Data type

Flags

Default

1A71:0

AI Gyro X TxPDO-Map Samples 20

PDO Mapping TxPDO 114

UINT8

RO

0x14 (20dec)

1A71:01

SubIndex 001

1. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x01 (Sample))

UINT32

RO

0x6031:01, 32

1A71:02

SubIndex 002

2. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x02 (Sample))

UINT32

RO

0x6031:02, 32

1A71:03

SubIndex 003

3. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x03 (Sample))

UINT32

RO

0x6031:03, 32

1A71:04

SubIndex 004

4. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x04 (Sample))

UINT32

RO

0x6031:04, 32

1A71:05

SubIndex 005

5. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x05 (Sample))

UINT32

RO

0x6031:05, 32

1A71:06

SubIndex 006

6. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x06 (Sample))

UINT32

RO

0x6031:06, 32

1A71:07

SubIndex 007

7. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x07 (Sample))

UINT32

RO

0x6031:07, 32

1A71:08

SubIndex 008

8. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x08 (Sample))

UINT32

RO

0x6031:08, 32

1A71:09

SubIndex 009

9. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x09 (Sample))

UINT32

RO

0x6031:09, 32

1A71:0A

SubIndex 010

10. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x0A (Sample))

UINT32

RO

0x6031:0A, 32

1A71:0B

SubIndex 011

11. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x0B (Sample))

UINT32

RO

0x6031:0B, 32

1A71:0C

SubIndex 012

12. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x0C (Sample))

UINT32

RO

0x6031:0C, 32

1A71:0D

SubIndex 013

13. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x0D (Sample))

UINT32

RO

0x6031:0D, 32

1A71:0E

SubIndex 014

14. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x0E (Sample))

UINT32

RO

0x6031:0E, 32

1A71:0F

SubIndex 015

15. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x0F (Sample))

UINT32

RO

0x6031:0F, 32

1A71:10

SubIndex 016

16. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x10 (Sample))

UINT32

RO

0x6031:10, 32

1A71:11

SubIndex 017

17. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x11 (Sample))

UINT32

RO

0x6031:11, 32

1A71:12

SubIndex 018

18. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x12 (Sample))

UINT32

RO

0x6031:12, 32

1A71:13

SubIndex 019

19. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x13 (Sample))

UINT32

RO

0x6031:13, 32

1A71:14

SubIndex 020

20. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x14 (Sample))

UINT32

RO

0x6031:14, 32

Index 1A72 AI Gyro X TxPDO-Map Samples 40 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A72:0

AI Gyro X TxPDO-Map Samples 40 (Real32)

PDO Mapping TxPDO 115

UINT8

RO

0x28 (40dec)

1A72:01

SubIndex 001

1. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6033:01, 32

1A72:02

SubIndex 002

2. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6033:02, 32

1A72:03

SubIndex 003

3. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6033:03, 32

1A72:04

SubIndex 004

4. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6033:04, 32

1A72:05

SubIndex 005

5. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x05 (Sample))

UINT32

RO

0x6033:05, 32

1A72:06

SubIndex 006

6. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x06 (Sample))

UINT32

RO

0x6033:06, 32

1A72:07

SubIndex 007

7. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x07 (Sample))

UINT32

RO

0x6033:07, 32

1A72:08

SubIndex 008

8. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x08 (Sample))

UINT32

RO

0x6033:08, 32

1A72:09

SubIndex 009

9. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x09 (Sample))

UINT32

RO

0x6033:09, 32

1A72:0A

SubIndex 010

10. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x0A (Sample))

UINT32

RO

0x6033:0A, 32

1A72:0B

SubIndex 011

11. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x0B (Sample))

UINT32

RO

0x6033:0B, 32

1A72:0C

SubIndex 012

12. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x0C (Sample))

UINT32

RO

0x6033:0C, 32

1A72:0D

SubIndex 013

13. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x0D (Sample))

UINT32

RO

0x6033:0D, 32

1A72:0E

SubIndex 014

14. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x0E (Sample))

UINT32

RO

0x6033:0E, 32

1A72:0F

SubIndex 015

15. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x0F (Sample))

UINT32

RO

0x6033:0F, 32

1A72:10

SubIndex 016

16. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x10 (Sample))

UINT32

RO

0x6033:10, 32

1A72:11

SubIndex 017

17. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x11 (Sample))

UINT32

RO

0x6033:11, 32

1A72:12

SubIndex 018

18. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x12 (Sample))

UINT32

RO

0x6033:12, 32

1A72:13

SubIndex 019

19. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x13 (Sample))

UINT32

RO

0x6033:13, 32

1A72:14

SubIndex 020

20. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x14 (Sample))

UINT32

RO

0x6033:14, 32

1A72:15

SubIndex 021

21. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x15 (Sample))

UINT32

RO

0x6033:15, 32

1A72:16

SubIndex 022

22. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x16 (Sample))

UINT32

RO

0x6033:16, 32

1A72:17

SubIndex 023

23. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x17 (Sample))

UINT32

RO

0x6033:17, 32

1A72:18

SubIndex 024

24. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x18 (Sample))

UINT32

RO

0x6033:18, 32

1A72:19

SubIndex 025

25. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x19 (Sample))

UINT32

RO

0x6033:19, 32

1A72:1A

SubIndex 026

26. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x1A (Sample))

UINT32

RO

0x6033:1A, 32

1A72:1B

SubIndex 027

27. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x1B (Sample))

UINT32

RO

0x6033:1B, 32

1A72:1C

SubIndex 028

28. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x1C (Sample))

UINT32

RO

0x6033:1C, 32

1A72:1D

SubIndex 029

29. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x1D (Sample))

UINT32

RO

0x6033:1D, 32

Index (hex)

Name

Meaning

Data type

Flags

Default

1A72:1E

SubIndex 030

30. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x1E (Sample))

UINT32

RO

0x6033:1E, 32

1A72:1F

SubIndex 031

31. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x1F (Sample))

UINT32

RO

0x6033:1F, 32

1A72:20

SubIndex 032

32. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x20 (Sample))

UINT32

RO

0x6033:20, 32

1A72:21

SubIndex 033

33. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x21 (Sample))

UINT32

RO

0x6033:21, 32

1A72:22

SubIndex 034

34. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x22 (Sample))

UINT32

RO

0x6033:22, 32

1A72:23

SubIndex 035

35. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x23 (Sample))

UINT32

RO

0x6033:23, 32

1A72:24

SubIndex 036

36. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x24 (Sample))

UINT32

RO

0x6033:24, 32

1A72:25

SubIndex 037

37. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x25 (Sample))

UINT32

RO

0x6033:25, 32

1A72:26

SubIndex 038

38. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x26 (Sample))

UINT32

RO

0x6033:26, 32

1A72:27

SubIndex 039

39. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x27 (Sample))

UINT32

RO

0x6033:27, 32

1A72:28

SubIndex 040

40. PDO Mapping entry (object 0x6033 (AI Gyro Samples (Real32)), entry 0x28 (Sample))

UINT32

RO

0x6033:28, 32

Index 1A73 AI Gyro X TxPDO-Map Samples 40

Index (hex)

Name

Meaning

Data type

Flags

Default

1A73:0

AI Gyro X TxPDO-Map Samples 40

PDO Mapping TxPDO 116

UINT8

RO

0x28 (40dec)

1A73:01

SubIndex 001

1. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x01 (Sample))

UINT32

RO

0x6031:01, 32

1A73:02

SubIndex 002

2. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x02 (Sample))

UINT32

RO

0x6031:02, 32

1A73:03

SubIndex 003

3. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x03 (Sample))

UINT32

RO

0x6031:03, 32

1A73:04

SubIndex 004

4. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x04 (Sample))

UINT32

RO

0x6031:04, 32

1A73:05

SubIndex 005

5. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x05 (Sample))

UINT32

RO

0x6031:05, 32

1A73:06

SubIndex 006

6. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x06 (Sample))

UINT32

RO

0x6031:06, 32

1A73:07

SubIndex 007

7. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x07 (Sample))

UINT32

RO

0x6031:07, 32

1A73:08

SubIndex 008

8. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x08 (Sample))

UINT32

RO

0x6031:08, 32

1A73:09

SubIndex 009

9. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x09 (Sample))

UINT32

RO

0x6031:09, 32

1A73:0A

SubIndex 010

10. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x0A (Sample))

UINT32

RO

0x6031:0A, 32

1A73:0B

SubIndex 011

11. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x0B (Sample))

UINT32

RO

0x6031:0B, 32

1A73:0C

SubIndex 012

12. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x0C (Sample))

UINT32

RO

0x6031:0C, 32

1A73:0D

SubIndex 013

13. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x0D (Sample))

UINT32

RO

0x6031:0D, 32

Index (hex)

Name

Meaning

Data type

Flags

Default

1A73:0E

SubIndex 014

14. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x0E (Sample))

UINT32

RO

0x6031:0E, 32

1A73:0F

SubIndex 015

15. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x0F (Sample))

UINT32

RO

0x6031:0F, 32

1A73:10

SubIndex 016

16. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x10 (Sample))

UINT32

RO

0x6031:10, 32

1A73:11

SubIndex 017

17. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x11 (Sample))

UINT32

RO

0x6031:11, 32

1A73:12

SubIndex 018

18. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x12 (Sample))

UINT32

RO

0x6031:12, 32

1A73:13

SubIndex 019

19. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x13 (Sample))

UINT32

RO

0x6031:13, 32

1A73:14

SubIndex 020

20. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x14 (Sample))

UINT32

RO

0x6031:14, 32

1A73:15

SubIndex 021

21. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x15 (Sample))

UINT32

RO

0x6031:15, 32

1A73:16

SubIndex 022

22. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x16 (Sample))

UINT32

RO

0x6031:16, 32

1A73:17

SubIndex 023

23. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x17 (Sample))

UINT32

RO

0x6031:17, 32

1A73:18

SubIndex 024

24. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x18 (Sample))

UINT32

RO

0x6031:18, 32

1A73:19

SubIndex 025

25. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x19 (Sample))

UINT32

RO

0x6031:19, 32

1A73:1A

SubIndex 026

26. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x1A (Sample))

UINT32

RO

0x6031:1A, 32

1A73:1B

SubIndex 027

27. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x1B (Sample))

UINT32

RO

0x6031:1B, 32

1A73:1C

SubIndex 028

28. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x1C (Sample))

UINT32

RO

0x6031:1C, 32

1A73:1D

SubIndex 029

29. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x1D (Sample))

UINT32

RO

0x6031:1D, 32

1A73:1E

SubIndex 030

30. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x1E (Sample))

UINT32

RO

0x6031:1E, 32

1A73:1F

SubIndex 031

31. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x1F (Sample))

UINT32

RO

0x6031:1F, 32

1A73:20

SubIndex 032

32. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x20 (Sample))

UINT32

RO

0x6031:20, 32

1A73:21

SubIndex 033

33. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x21 (Sample))

UINT32

RO

0x6031:21, 32

1A73:22

SubIndex 034

34. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x22 (Sample))

UINT32

RO

0x6031:22, 32

1A73:23

SubIndex 035

35. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x23 (Sample))

UINT32

RO

0x6031:23, 32

1A73:24

SubIndex 036

36. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x24 (Sample))

UINT32

RO

0x6031:24, 32

1A73:25

SubIndex 037

37. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x25 (Sample))

UINT32

RO

0x6031:25, 32

1A73:26

SubIndex 038

38. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x26 (Sample))

UINT32

RO

0x6031:26, 32

1A73:27

SubIndex 039

39. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x27 (Sample))

UINT32

RO

0x6031:27, 32

1A73:28

SubIndex 040

40. PDO Mapping entry (object 0x6031 (AI Gyro Samples), entry 0x28 (Sample))

UINT32

RO

0x6031:28, 32

Index 1A80 AI Gyro Y TxPDO-Map Status

Index (hex)

Name

Meaning

Data type

Flags

Default

1A80:0

AI Gyro Y TxPDO-Map Status

PDO Mapping TxPDO 129

UINT8

RO

0x08 (8dec)

1A80:01

SubIndex 001

1. PDO Mapping entry (8 bits align)

UINT32

RO

0x0000:00, 8

1A80:02

SubIndex 002

2. PDO Mapping entry (object 0x6040 (AI Gyro Inputs), entry 0x09 (Self test status))

UINT32

RO

0x6040:09, 2

1A80:03

SubIndex 003

3. PDO Mapping entry (object 0x6040 (AI Gyro Inputs), entry 0x0B (Slope detected))

UINT32

RO

0x6040:0B, 1

1A80:04

SubIndex 004

4. PDO Mapping entry (3 bits align)

UINT32

RO

0x0000:00, 2

1A80:05

SubIndex 005

5. PDO Mapping entry (object 0x6040 (AI Gyro Inputs), entry 0x0F (TxPDO State))

UINT32

RO

0x6040:0E, 1

1A80:06

SubIndex 006

6. PDO Mapping entry (object 0x6040 (AI Gyro Inputs), entry 0x10 (TxPDO Toggle))

UINT32

RO

0x6040:0F, 1

1A80:07

SubIndex 007

7. PDO Mapping entry (16 bits align)

UINT32

RO

0x6040:10, 1

1A80:08

SubIndex 008

8. PDO Mapping entry (16 bits align)

UINT32

RO

0x0000:00, 16

Index 1A81 AI Gyro Y TxPDO-Map Input Cycle Counter

Index (hex)

Name

Meaning

Data type

Flags

Default

1A81:0

AI Gyro Y TxPDO-Map Input Cycle Counter

PDO Mapping TxPDO 130

UINT8

RO

0x01 (1dec)

1A81:01

SubIndex 001

1. PDO Mapping entry (8 bits align)

UINT32

RO

0x6040:14, 16

Index 1A82 AI Gyro Y TxPDO-Map Inputs Legacy Real

Index (hex)

Name

Meaning

Data type

Flags

Default

1A82:0

AI Gyro Y TxPDO-Map Inputs Legacy Real

PDO Mapping TxPDO 131

UINT8

RO

0x09 (9dec)

1A82:01

SubIndex 001

1. PDO Mapping entry (8 bits align)

UINT32

RO

0x0000:00, 8

1A82:02

SubIndex 002

2. PDO Mapping entry (object 0x6040 (AI Gyro Inputs), entry 0x09 (Self test status))

UINT32

RO

0x6040:09, 2

1A82:03

SubIndex 003

3. PDO Mapping entry (object 0x6040 (AI Gyro Inputs), entry 0x0B (Slope detected))

UINT32

RO

0x6040:0B, 1

1A82:04

SubIndex 004

4. PDO Mapping entry (3 bits align)

UINT32

RO

0x0000:00, 2

1A82:05

SubIndex 005

5. PDO Mapping entry (object 0x6040 (AI Gyro Inputs), entry 0x0F (TxPDO State))

UINT32

RO

0x6040:0E, 1

1A82:06

SubIndex 006

6. PDO Mapping entry (object 0x6040 (AI Gyro Inputs), entry 0x10 (TxPDO Toggle))

UINT32

RO

0x6040:0F, 1

1A82:07

SubIndex 007

7. PDO Mapping entry (16 bits align)

UINT32

RO

0x6040:10, 1

1A82:08

SubIndex 008

8. PDO Mapping entry (object 0x6040 (AI Gyro Inputs), entry 0x13 (Value (Real32)))

UINT32

RO

0x0000:00, 16

1A82:09

SubIndex 009

9. PDO Mapping entry (object 0x6040 (AI Gyro Inputs), entry 0x13 (Value (Real32)))

UINT32

RO

0x6040:13, 32

Index 1A83 AI Gyro Y TxPDO-Map Inputs Legacy Int

Index (hex)

Name

Meaning

Data type

Flags

Default

1A83:0

AI Gyro Y TxPDO-Map Inputs Legacy Int

PDO Mapping TxPDO 132

UINT8

RO

0x09 (9dec)

1A83:01

SubIndex 001

1. PDO Mapping entry (8 bits align)

UINT32

RO

0x0000:00, 8

1A83:02

SubIndex 002

2. PDO Mapping entry (object 0x6040 (AI Gyro Inputs), entry 0x09 (Self test status))

UINT32

RO

0x6040:09, 2

1A83:03

SubIndex 003

3. PDO Mapping entry (object 0x6040 (AI Gyro Inputs), entry 0x0B (Slope detected))

UINT32

RO

0x6040:0B, 1

1A83:04

SubIndex 004

4. PDO Mapping entry (3 bits align)

UINT32

RO

0x0000:00, 2

1A83:05

SubIndex 005

5. PDO Mapping entry (object 0x6040 (AI Gyro Inputs), entry 0x0F (TxPDO State))

UINT32

RO

0x6040:0E, 1

1A83:06

SubIndex 006

6. PDO Mapping entry (object 0x6040 (AI Gyro Inputs), entry 0x10 (TxPDO Toggle))

UINT32

RO

0x6040:0F, 1

1A83:07

SubIndex 007

7. PDO Mapping entry (16 bits align)

UINT32

RO

0x6040:10, 1

1A83:08

SubIndex 008

8. PDO Mapping entry (object 0x6040 (AI Gyro Inputs), entry 0x12 (Value))

UINT32

RO

0x0000:00, 16

1A83:09

SubIndex 009

9. PDO Mapping entry (object 0x6040 (AI Gyro Inputs), entry 0x12 (Value))

UINT32

RO

0x6040:12, 32

Index 1A84 AI Gyro Y TxPDO-Map Samples 1 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A84:0

AI Gyro Y TxPDO-Map Samples 1 (Real32)

PDO Mapping TxPDO 133

UINT8

RO

0x01 (1dec)

1A84:01

SubIndex 001

1. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6043:01, 32

Index 1A85 AI Gyro Y TxPDO-Map Samples 1

Index (hex)

Name

Meaning

Data type

Flags

Default

1A85:0

AI Gyro Y TxPDO-Map Samples 1

PDO Mapping TxPDO 134

UINT8

RO

0x01 (1dec)

1A85:01

SubIndex 001

1. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x01 (Sample))

UINT32

RO

0x6041:01, 32

Index 1A86 AI Gyro Y TxPDO-Map Samples 2 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A86:0

AI Gyro Y TxPDO-Map Samples 2 (Real32)

PDO Mapping TxPDO 135

UINT8

RO

0x02 (2dec)

1A86:01

SubIndex 001

1. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6043:01, 32

1A86:02

SubIndex 002

2. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6043:02, 32

Index 1A87 AI Gyro Y TxPDO-Map Samples 2

Index (hex)

Name

Meaning

Data type

Flags

Default

1A87:0

AI Gyro Y TxPDO-Map Samples 2

PDO Mapping TxPDO 136

UINT8

RO

0x02 (2dec)

1A87:01

SubIndex 001

1. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x01 (Sample))

UINT32

RO

0x6041:01, 32

1A87:02

SubIndex 002

2. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x02 (Sample))

UINT32

RO

0x6041:02, 32

Index 1A88 AI Gyro Y TxPDO-Map Samples 4 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A88:0

AI Gyro Y TxPDO-Map Samples 4 (Real32)

PDO Mapping TxPDO 137

UINT8

RO

0x04 (4dec)

1A88:01

SubIndex 001

1. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6043:01, 32

1A88:02

SubIndex 002

2. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6043:02, 32

1A88:03

SubIndex 003

3. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6043:03, 32

1A88:04

SubIndex 004

4. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6043:04, 32

Index 1A89 AI Gyro Y TxPDO-Map Samples 4

Index (hex)

Name

Meaning

Data type

Flags

Default

1A89:0

AI Gyro Y TxPDO-Map Samples 4

PDO Mapping TxPDO 138

UINT8

RO

0x04 (4dec)

1A89:01

SubIndex 001

1. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x01 (Sample))

UINT32

RO

0x6041:01, 32

1A89:02

SubIndex 002

2. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x02 (Sample))

UINT32

RO

0x6041:02, 32

1A89:03

SubIndex 003

3. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x03 (Sample))

UINT32

RO

0x6041:03, 32

1A89:04

SubIndex 004

4. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x04 (Sample))

UINT32

RO

0x6041:04, 32

Index 1A8A AI Gyro Y TxPDO-Map Samples 8 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A8A:0

AI Gyro Y TxPDO-Map Samples 8 (Real32)

PDO Mapping TxPDO 139

UINT8

RO

0x08 (8dec)

1A8A:01

SubIndex 001

1. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6043:01, 32

1A8A:02

SubIndex 002

2. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6043:02, 32

1A8A:03

SubIndex 003

3. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6043:03, 32

1A8A:04

SubIndex 004

4. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6043:04, 32

1A8A:05

SubIndex 005

5. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x05 (Sample))

UINT32

RO

0x6043:05, 32

1A8A:06

SubIndex 006

6. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x06 (Sample))

UINT32

RO

0x6043:06, 32

1A8A:07

SubIndex 007

7. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x07 (Sample))

UINT32

RO

0x6043:07, 32

1A8A:08

SubIndex 008

8. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x08 (Sample))

UINT32

RO

0x6043:08, 32

Index 1A8B AI Gyro Y TxPDO-Map Samples 8

Index (hex)

Name

Meaning

Data type

Flags

Default

1A8B:0

AI Gyro Y TxPDO-Map Samples 8

PDO Mapping TxPDO 140

UINT8

RO

0x08 (8dec)

1A8B:01

SubIndex 001

1. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x01 (Sample))

UINT32

RO

0x6041:01, 32

1A8B:02

SubIndex 002

2. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x02 (Sample))

UINT32

RO

0x6041:02, 32

1A8B:03

SubIndex 003

3. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x03 (Sample))

UINT32

RO

0x6041:03, 32

1A8B:04

SubIndex 004

4. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x04 (Sample))

UINT32

RO

0x6041:04, 32

1A8B:05

SubIndex 005

5. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x05 (Sample))

UINT32

RO

0x6041:05, 32

1A8B:06

SubIndex 006

6. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x06 (Sample))

UINT32

RO

0x6041:06, 32

1A8B:07

SubIndex 007

7. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x07 (Sample))

UINT32

RO

0x6041:07, 32

1A8B:08

SubIndex 008

8. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x08 (Sample))

UINT32

RO

0x6041:08, 32

Index 1A8C AI Gyro Y TxPDO-Map Samples 10 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A8C:0

AI Gyro Y TxPDO-Map Samples 10 (Real32)

PDO Mapping TxPDO 141

UINT8

RO

0x0A (10dec)

1A8C:01

SubIndex 001

1. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6043:01, 32

1A8C:02

SubIndex 002

2. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6043:02, 32

1A8C:03

SubIndex 003

3. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6043:03, 32

1A8C:04

SubIndex 004

4. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6043:04, 32

1A8C:05

SubIndex 005

5. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x05 (Sample))

UINT32

RO

0x6043:05, 32

1A8C:06

SubIndex 006

6. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x06 (Sample))

UINT32

RO

0x6043:06, 32

1A8C:07

SubIndex 007

7. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x07 (Sample))

UINT32

RO

0x6043:07, 32

1A8C:08

SubIndex 008

8. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x08 (Sample))

UINT32

RO

0x6043:08, 32

1A8C:09

SubIndex 009

9. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x09 (Sample))

UINT32

RO

0x6043:09, 32

1A8C:0A

SubIndex 010

10. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x0A (Sample))

UINT32

RO

0x6043:0A, 32

Index 1A8D AI Gyro Y TxPDO-Map Samples 10

Index (hex)

Name

Meaning

Data type

Flags

Default

1A8D:0

AI Gyro Y TxPDO-Map Samples 10

PDO Mapping TxPDO 142

UINT8

RO

0x0A (10dec)

1A8D:01

SubIndex 001

1. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x01 (Sample))

UINT32

RO

0x6041:01, 32

1A8D:02

SubIndex 002

2. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x02 (Sample))

UINT32

RO

0x6041:02, 32

1A8D:03

SubIndex 003

3. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x03 (Sample))

UINT32

RO

0x6041:03, 32

1A8D:04

SubIndex 004

4. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x04 (Sample))

UINT32

RO

0x6041:04, 32

1A8D:05

SubIndex 005

5. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x05 (Sample))

UINT32

RO

0x6041:05, 32

1A8D:06

SubIndex 006

6. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x06 (Sample))

UINT32

RO

0x6041:06, 32

1A8D:07

SubIndex 007

7. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x07 (Sample))

UINT32

RO

0x6041:07, 32

1A8D:08

SubIndex 008

8. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x08 (Sample))

UINT32

RO

0x6041:08, 32

1A8D:09

SubIndex 009

9. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x09 (Sample))

UINT32

RO

0x6041:09, 32

1A8D:0A

SubIndex 010

10. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x0A (Sample))

UINT32

RO

0x6041:0A, 32

Index 1A8E AI Gyro Y TxPDO-Map Samples 16 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A8E:0

AI Gyro Y TxPDO-Map Samples 16 (Real32)

PDO Mapping TxPDO 143

UINT8

RO

0x10 (16dec)

1A8E:01

SubIndex 001

1. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6043:01, 32

1A8E:02

SubIndex 002

2. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6043:02, 32

1A8E:03

SubIndex 003

3. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6043:03, 32

1A8E:04

SubIndex 004

4. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6043:04, 32

1A8E:05

SubIndex 005

5. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x05 (Sample))

UINT32

RO

0x6043:05, 32

1A8E:06

SubIndex 006

6. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x06 (Sample))

UINT32

RO

0x6043:06, 32

1A8E:07

SubIndex 007

7. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x07 (Sample))

UINT32

RO

0x6043:07, 32

1A8E:08

SubIndex 008

8. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x08 (Sample))

UINT32

RO

0x6043:08, 32

1A8E:09

SubIndex 009

9. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x09 (Sample))

UINT32

RO

0x6043:09, 32

1A8E:0A

SubIndex 010

10. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x0A (Sample))

UINT32

RO

0x6043:0A, 32

1A8E:0B

SubIndex 011

11. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x0B (Sample))

UINT32

RO

0x6043:0B, 32

1A8E:0C

SubIndex 012

12. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x0C (Sample))

UINT32

RO

0x6043:0C, 32

1A8E:0D

SubIndex 013

13. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x0D (Sample))

UINT32

RO

0x6043:0D, 32

1A8E:0E

SubIndex 014

14. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x0E (Sample))

UINT32

RO

0x6043:0E, 32

1A8E:0F

SubIndex 015

15. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x0F (Sample))

UINT32

RO

0x6043:0F, 32

1A8E:10

SubIndex 016

16. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x10 (Sample))

UINT32

RO

0x6043:10, 32

Index 1A8F AI Gyro Y TxPDO-Map Samples 16

Index (hex)

Name

Meaning

Data type

Flags

Default

1A8F:0

AI Gyro Y TxPDO-Map Samples 16

PDO Mapping TxPDO 144

UINT8

RO

0x10 (16dec)

1A8F:01

SubIndex 001

1. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x01 (Sample))

UINT32

RO

0x6041:01, 32

1A8F:02

SubIndex 002

2. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x02 (Sample))

UINT32

RO

0x6041:02, 32

1A8F:03

SubIndex 003

3. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x03 (Sample))

UINT32

RO

0x6041:03, 32

1A8F:04

SubIndex 004

4. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x04 (Sample))

UINT32

RO

0x6041:04, 32

1A8F:05

SubIndex 005

5. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x05 (Sample))

UINT32

RO

0x6041:05, 32

1A8F:06

SubIndex 006

6. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x06 (Sample))

UINT32

RO

0x6041:06, 32

1A8F:07

SubIndex 007

7. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x07 (Sample))

UINT32

RO

0x6041:07, 32

1A8F:08

SubIndex 008

8. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x08 (Sample))

UINT32

RO

0x6041:08, 32

1A8F:09

SubIndex 009

9. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x09 (Sample))

UINT32

RO

0x6041:09, 32

1A8F:0A

SubIndex 010

10. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x0A (Sample))

UINT32

RO

0x6041:0A, 32

1A8F:0B

SubIndex 011

11. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x0B (Sample))

UINT32

RO

0x6041:0B, 32

1A8F:0C

SubIndex 012

12. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x0C (Sample))

UINT32

RO

0x6041:0C, 32

1A8F:0D

SubIndex 013

13. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x0D (Sample))

UINT32

RO

0x6041:0D, 32

1A8F:0E

SubIndex 014

14. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x0E (Sample))

UINT32

RO

0x6041:0E, 32

1A8F:0F

SubIndex 015

15. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x0F (Sample))

UINT32

RO

0x6041:0F, 32

1A8F:10

SubIndex 016

16. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x10 (Sample))

UINT32

RO

0x6041:10, 32

Index 1A90 AI Gyro Y TxPDO-Map Samples 20 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A90:0

AI Gyro Y TxPDO-Map Samples 20 (Real32)

PDO Mapping TxPDO 145

UINT8

RO

0x14 (20dec)

1A90:01

SubIndex 001

1. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6043:01, 32

1A90:02

SubIndex 002

2. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6043:02, 32

1A90:03

SubIndex 003

3. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6043:03, 32

1A90:04

SubIndex 004

4. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6043:04, 32

1A90:05

SubIndex 005

5. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x05 (Sample))

UINT32

RO

0x6043:05, 32

1A90:06

SubIndex 006

6. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x06 (Sample))

UINT32

RO

0x6043:06, 32

1A90:07

SubIndex 007

7. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x07 (Sample))

UINT32

RO

0x6043:07, 32

1A90:08

SubIndex 008

8. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x08 (Sample))

UINT32

RO

0x6043:08, 32

1A90:09

SubIndex 009

9. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x09 (Sample))

UINT32

RO

0x6043:09, 32

1A90:0A

SubIndex 010

10. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x0A (Sample))

UINT32

RO

0x6043:0A, 32

1A90:0B

SubIndex 011

11. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x0B (Sample))

UINT32

RO

0x6043:0B, 32

1A90:0C

SubIndex 012

12. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x0C (Sample))

UINT32

RO

0x6043:0C, 32

1A90:0D

SubIndex 013

13. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x0D (Sample))

UINT32

RO

0x6043:0D, 32

1A90:0E

SubIndex 014

14. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x0E (Sample))

UINT32

RO

0x6043:0E, 32

1A90:0F

SubIndex 015

15. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x0F (Sample))

UINT32

RO

0x6043:0F, 32

1A90:10

SubIndex 016

16. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x10 (Sample))

UINT32

RO

0x6043:10, 32

1A90:11

SubIndex 017

17. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x11 (Sample))

UINT32

RO

0x6043:11, 32

1A90:12

SubIndex 018

18. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x12 (Sample))

UINT32

RO

0x6043:12, 32

1A90:13

SubIndex 019

19. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x13 (Sample))

UINT32

RO

0x6043:13, 32

1A90:14

SubIndex 020

20. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x14 (Sample))

UINT32

RO

0x6043:14, 32

Index 1A91 AI Gyro Y TxPDO-Map Samples 20

Index (hex)

Name

Meaning

Data type

Flags

Default

1A91:0

AI Gyro Y TxPDO-Map Samples 20

PDO Mapping TxPDO 146

UINT8

RO

0x14 (20dec)

1A91:01

SubIndex 001

1. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x01 (Sample))

UINT32

RO

0x6041:01, 32

1A91:02

SubIndex 002

2. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x02 (Sample))

UINT32

RO

0x6041:02, 32

1A91:03

SubIndex 003

3. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x03 (Sample))

UINT32

RO

0x6041:03, 32

1A91:04

SubIndex 004

4. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x04 (Sample))

UINT32

RO

0x6041:04, 32

1A91:05

SubIndex 005

5. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x05 (Sample))

UINT32

RO

0x6041:05, 32

1A91:06

SubIndex 006

6. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x06 (Sample))

UINT32

RO

0x6041:06, 32

1A91:07

SubIndex 007

7. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x07 (Sample))

UINT32

RO

0x6041:07, 32

1A91:08

SubIndex 008

8. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x08 (Sample))

UINT32

RO

0x6041:08, 32

1A91:09

SubIndex 009

9. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x09 (Sample))

UINT32

RO

0x6041:09, 32

1A91:0A

SubIndex 010

10. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x0A (Sample))

UINT32

RO

0x6041:0A, 32

1A91:0B

SubIndex 011

11. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x0B (Sample))

UINT32

RO

0x6041:0B, 32

1A91:0C

SubIndex 012

12. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x0C (Sample))

UINT32

RO

0x6041:0C, 32

1A91:0D

SubIndex 013

13. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x0D (Sample))

UINT32

RO

0x6041:0D, 32

1A91:0E

SubIndex 014

14. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x0E (Sample))

UINT32

RO

0x6041:0E, 32

1A91:0F

SubIndex 015

15. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x0F (Sample))

UINT32

RO

0x6041:0F, 32

1A91:10

SubIndex 016

16. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x10 (Sample))

UINT32

RO

0x6041:10, 32

1A91:11

SubIndex 017

17. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x11 (Sample))

UINT32

RO

0x6041:11, 32

1A91:12

SubIndex 018

18. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x12 (Sample))

UINT32

RO

0x6041:12, 32

1A91:13

SubIndex 019

19. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x13 (Sample))

UINT32

RO

0x6041:13, 32

1A91:14

SubIndex 020

20. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x14 (Sample))

UINT32

RO

0x6041:14, 32

Index 1A92 AI Gyro Y TxPDO-Map Samples 40 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A92:0

AI Gyro Y TxPDO-Map Samples 40 (Real32)

PDO Mapping TxPDO 147

UINT8

RO

0x28 (40dec)

1A92:01

SubIndex 001

1. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6043:01, 32

1A92:02

SubIndex 002

2. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6043:02, 32

1A92:03

SubIndex 003

3. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6043:03, 32

1A92:04

SubIndex 004

4. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6043:04, 32

1A92:05

SubIndex 005

5. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x05 (Sample))

UINT32

RO

0x6043:05, 32

1A92:06

SubIndex 006

6. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x06 (Sample))

UINT32

RO

0x6043:06, 32

1A92:07

SubIndex 007

7. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x07 (Sample))

UINT32

RO

0x6043:07, 32

1A92:08

SubIndex 008

8. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x08 (Sample))

UINT32

RO

0x6043:08, 32

1A92:09

SubIndex 009

9. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x09 (Sample))

UINT32

RO

0x6043:09, 32

1A92:0A

SubIndex 010

10. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x0A (Sample))

UINT32

RO

0x6043:0A, 32

1A92:0B

SubIndex 011

11. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x0B (Sample))

UINT32

RO

0x6043:0B, 32

1A92:0C

SubIndex 012

12. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x0C (Sample))

UINT32

RO

0x6043:0C, 32

1A92:0D

SubIndex 013

13. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x0D (Sample))

UINT32

RO

0x6043:0D, 32

1A92:0E

SubIndex 014

14. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x0E (Sample))

UINT32

RO

0x6043:0E, 32

1A92:0F

SubIndex 015

15. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x0F (Sample))

UINT32

RO

0x6043:0F, 32

1A92:10

SubIndex 016

16. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x10 (Sample))

UINT32

RO

0x6043:10, 32

1A92:11

SubIndex 017

17. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x11 (Sample))

UINT32

RO

0x6043:11, 32

1A92:12

SubIndex 018

18. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x12 (Sample))

UINT32

RO

0x6043:12, 32

1A92:13

SubIndex 019

19. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x13 (Sample))

UINT32

RO

0x6043:13, 32

1A92:14

SubIndex 020

20. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x14 (Sample))

UINT32

RO

0x6043:14, 32

1A92:15

SubIndex 021

21. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x15 (Sample))

UINT32

RO

0x6043:15, 32

1A92:16

SubIndex 022

22. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x16 (Sample))

UINT32

RO

0x6043:16, 32

1A92:17

SubIndex 023

23. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x17 (Sample))

UINT32

RO

0x6043:17, 32

1A92:18

SubIndex 024

24. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x18 (Sample))

UINT32

RO

0x6043:18, 32

1A92:19

SubIndex 025

25. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x19 (Sample))

UINT32

RO

0x6043:19, 32

1A92:1A

SubIndex 026

26. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x1A (Sample))

UINT32

RO

0x6043:1A, 32

1A92:1B

SubIndex 027

27. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x1B (Sample))

UINT32

RO

0x6043:1B, 32

1A92:1C

SubIndex 028

28. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x1C (Sample))

UINT32

RO

0x6043:1C, 32

1A92:1D

SubIndex 029

29. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x1D (Sample))

UINT32

RO

0x6043:1D, 32

Index (hex)

Name

Meaning

Data type

Flags

Default

1A92:1E

SubIndex 030

30. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x1E (Sample))

UINT32

RO

0x6043:1E, 32

1A92:1F

SubIndex 031

31. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x1F (Sample))

UINT32

RO

0x6043:1F, 32

1A92:20

SubIndex 032

32. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x20 (Sample))

UINT32

RO

0x6043:20, 32

1A92:21

SubIndex 033

33. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x21 (Sample))

UINT32

RO

0x6043:21, 32

1A92:22

SubIndex 034

34. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x22 (Sample))

UINT32

RO

0x6043:22, 32

1A92:23

SubIndex 035

35. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x23 (Sample))

UINT32

RO

0x6043:23, 32

1A92:24

SubIndex 036

36. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x24 (Sample))

UINT32

RO

0x6043:24, 32

1A92:25

SubIndex 037

37. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x25 (Sample))

UINT32

RO

0x6043:25, 32

1A92:26

SubIndex 038

38. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x26 (Sample))

UINT32

RO

0x6043:26, 32

1A92:27

SubIndex 039

39. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x27 (Sample))

UINT32

RO

0x6043:27, 32

1A92:28

SubIndex 040

40. PDO Mapping entry (object 0x6043 (AI Gyro Samples (Real32)), entry 0x28 (Sample))

UINT32

RO

0x6043:28, 32

Index 1A93 AI Gyro Y TxPDO-Map Samples 40

Index (hex)

Name

Meaning

Data type

Flags

Default

1A93:0

AI Gyro Y TxPDO-Map Samples 40

PDO Mapping TxPDO 148

UINT8

RO

0x28 (40dec)

1A93:01

SubIndex 001

1. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x01 (Sample))

UINT32

RO

0x6041:01, 32

1A93:02

SubIndex 002

2. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x02 (Sample))

UINT32

RO

0x6041:02, 32

1A93:03

SubIndex 003

3. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x03 (Sample))

UINT32

RO

0x6041:03, 32

1A93:04

SubIndex 004

4. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x04 (Sample))

UINT32

RO

0x6041:04, 32

1A93:05

SubIndex 005

5. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x05 (Sample))

UINT32

RO

0x6041:05, 32

1A93:06

SubIndex 006

6. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x06 (Sample))

UINT32

RO

0x6041:06, 32

1A93:07

SubIndex 007

7. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x07 (Sample))

UINT32

RO

0x6041:07, 32

1A93:08

SubIndex 008

8. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x08 (Sample))

UINT32

RO

0x6041:08, 32

1A93:09

SubIndex 009

9. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x09 (Sample))

UINT32

RO

0x6041:09, 32

1A93:0A

SubIndex 010

10. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x0A (Sample))

UINT32

RO

0x6041:0A, 32

1A93:0B

SubIndex 011

11. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x0B (Sample))

UINT32

RO

0x6041:0B, 32

1A93:0C

SubIndex 012

12. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x0C (Sample))

UINT32

RO

0x6041:0C, 32

1A93:0D

SubIndex 013

13. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x0D (Sample))

UINT32

RO

0x6041:0D, 32

Index (hex)

Name

Meaning

Data type

Flags

Default

1A93:0E

SubIndex 014

14. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x0E (Sample))

UINT32

RO

0x6041:0E, 32

1A93:0F

SubIndex 015

15. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x0F (Sample))

UINT32

RO

0x6041:0F, 32

1A93:10

SubIndex 016

16. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x10 (Sample))

UINT32

RO

0x6041:10, 32

1A93:11

SubIndex 017

17. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x11 (Sample))

UINT32

RO

0x6041:11, 32

1A93:12

SubIndex 018

18. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x12 (Sample))

UINT32

RO

0x6041:12, 32

1A93:13

SubIndex 019

19. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x13 (Sample))

UINT32

RO

0x6041:13, 32

1A93:14

SubIndex 020

20. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x14 (Sample))

UINT32

RO

0x6041:14, 32

1A93:15

SubIndex 021

21. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x15 (Sample))

UINT32

RO

0x6041:15, 32

1A93:16

SubIndex 022

22. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x16 (Sample))

UINT32

RO

0x6041:16, 32

1A93:17

SubIndex 023

23. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x17 (Sample))

UINT32

RO

0x6041:17, 32

1A93:18

SubIndex 024

24. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x18 (Sample))

UINT32

RO

0x6041:18, 32

1A93:19

SubIndex 025

25. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x19 (Sample))

UINT32

RO

0x6041:19, 32

1A93:1A

SubIndex 026

26. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x1A (Sample))

UINT32

RO

0x6041:1A, 32

1A93:1B

SubIndex 027

27. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x1B (Sample))

UINT32

RO

0x6041:1B, 32

1A93:1C

SubIndex 028

28. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x1C (Sample))

UINT32

RO

0x6041:1C, 32

1A93:1D

SubIndex 029

29. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x1D (Sample))

UINT32

RO

0x6041:1D, 32

1A93:1E

SubIndex 030

30. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x1E (Sample))

UINT32

RO

0x6041:1E, 32

1A93:1F

SubIndex 031

31. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x1F (Sample))

UINT32

RO

0x6041:1F, 32

1A93:20

SubIndex 032

32. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x20 (Sample))

UINT32

RO

0x6041:20, 32

1A93:21

SubIndex 033

33. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x21 (Sample))

UINT32

RO

0x6041:21, 32

1A93:22

SubIndex 034

34. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x22 (Sample))

UINT32

RO

0x6041:22, 32

1A93:23

SubIndex 035

35. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x23 (Sample))

UINT32

RO

0x6041:23, 32

1A93:24

SubIndex 036

36. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x24 (Sample))

UINT32

RO

0x6041:24, 32

1A93:25

SubIndex 037

37. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x25 (Sample))

UINT32

RO

0x6041:25, 32

1A93:26

SubIndex 038

38. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x26 (Sample))

UINT32

RO

0x6041:26, 32

1A93:27

SubIndex 039

39. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x27 (Sample))

UINT32

RO

0x6041:27, 32

1A93:28

SubIndex 040

40. PDO Mapping entry (object 0x6041 (AI Gyro Samples), entry 0x28 (Sample))

UINT32

RO

0x6041:28, 32

Index 1AA0 AI Gyro Z TxPDO-Map Status

Index (hex)

Name

Meaning

Data type

Flags

Default

1AA0:0

AI Gyro Z TxPDO-Map Status

PDO Mapping TxPDO 161

UINT8

RO

0x08 (8dec)

1AA0:01

SubIndex 001

1. PDO Mapping entry (8 bits align)

UINT32

RO

0x0000:00, 8

1AA0:02

SubIndex 002

2. PDO Mapping entry (object 0x6050 (AI Gyro Inputs), entry 0x09 (Self test status))

UINT32

RO

0x6050:09, 2

1AA0:03

SubIndex 003

3. PDO Mapping entry (object 0x6050 (AI Gyro Inputs), entry 0x0B (Slope detected))

UINT32

RO

0x6050:0B, 1

1AA0:04

SubIndex 004

4. PDO Mapping entry (3 bits align)

UINT32

RO

0x0000:00, 2

1AA0:05

SubIndex 005

5. PDO Mapping entry (object 0x6050 (AI Gyro Inputs), entry 0x0F (TxPDO State))

UINT32

RO

0x6050:0E, 1

1AA0:06

SubIndex 006

6. PDO Mapping entry (object 0x6050 (AI Gyro Inputs), entry 0x10 (TxPDO Toggle))

UINT32

RO

0x6050:0F, 1

1AA0:07

SubIndex 007

7. PDO Mapping entry (16 bits align)

UINT32

RO

0x6050:10, 1

1AA0:08

SubIndex 008

8. PDO Mapping entry (16 bits align)

UINT32

RO

0x0000:00, 16

Index 1AA1 AI Gyro Z TxPDO-Map Input Cycle Counter

Index (hex)

Name

Meaning

Data type

Flags

Default

1AA1:0

AI Gyro Z TxPDO-Map Input Cycle Counter

PDO Mapping TxPDO 162

UINT8

RO

0x01 (1dec)

1AA1:01

SubIndex 001

1. PDO Mapping entry (8 bits align)

UINT32

RO

0x6050:14, 16

Index 1AA2 AI Gyro Z TxPDO-Map Inputs Legacy Real

Index (hex)

Name

Meaning

Data type

Flags

Default

1AA2:0

AI Gyro Z TxPDO-Map Inputs Legacy Real

PDO Mapping TxPDO 163

UINT8

RO

0x09 (9dec)

1AA2:01

SubIndex 001

1. PDO Mapping entry (8 bits align)

UINT32

RO

0x0000:00, 8

1AA2:02

SubIndex 002

2. PDO Mapping entry (object 0x6050 (AI Gyro Inputs), entry 0x09 (Self test status))

UINT32

RO

0x6050:09, 2

1AA2:03

SubIndex 003

3. PDO Mapping entry (object 0x6050 (AI Gyro Inputs), entry 0x0B (Slope detected))

UINT32

RO

0x6050:0B, 1

1AA2:04

SubIndex 004

4. PDO Mapping entry (3 bits align)

UINT32

RO

0x0000:00, 2

1AA2:05

SubIndex 005

5. PDO Mapping entry (object 0x6050 (AI Gyro Inputs), entry 0x0F (TxPDO State))

UINT32

RO

0x6050:0E, 1

1AA2:06

SubIndex 006

6. PDO Mapping entry (object 0x6050 (AI Gyro Inputs), entry 0x10 (TxPDO Toggle))

UINT32

RO

0x6050:0F, 1

1AA2:07

SubIndex 007

7. PDO Mapping entry (16 bits align)

UINT32

RO

0x6050:10, 1

1AA2:08

SubIndex 008

8. PDO Mapping entry (object 0x6050 (AI Gyro Inputs), entry 0x13 (Value (Real32)))

UINT32

RO

0x0000:00, 16

1AA2:09

SubIndex 009

9. PDO Mapping entry (object 0x6050 (AI Gyro Inputs), entry 0x13 (Value (Real32)))

UINT32

RO

0x6050:13, 32

Index 1AA3 AI Gyro Z TxPDO-Map Inputs Legacy Int

Index (hex)

Name

Meaning

Data type

Flags

Default

1AA3:0

AI Gyro Z TxPDO-Map Inputs Legacy Int

PDO Mapping TxPDO 164

UINT8

RO

0x09 (9dec)

1AA3:01

SubIndex 001

1. PDO Mapping entry (8 bits align)

UINT32

RO

0x0000:00, 8

1AA3:02

SubIndex 002

2. PDO Mapping entry (object 0x6050 (AI Gyro Inputs), entry 0x09 (Self test status))

UINT32

RO

0x6050:09, 2

1AA3:03

SubIndex 003

3. PDO Mapping entry (object 0x6050 (AI Gyro Inputs), entry 0x0B (Slope detected))

UINT32

RO

0x6050:0B, 1

1AA3:04

SubIndex 004

4. PDO Mapping entry (3 bits align)

UINT32

RO

0x0000:00, 2

1AA3:05

SubIndex 005

5. PDO Mapping entry (object 0x6050 (AI Gyro Inputs), entry 0x0F (TxPDO State))

UINT32

RO

0x6050:0E, 1

1AA3:06

SubIndex 006

6. PDO Mapping entry (object 0x6050 (AI Gyro Inputs), entry 0x10 (TxPDO Toggle))

UINT32

RO

0x6050:0F, 1

1AA3:07

SubIndex 007

7. PDO Mapping entry (16 bits align)

UINT32

RO

0x6050:10, 1

1AA3:08

SubIndex 008

8. PDO Mapping entry (object 0x6050 (AI Gyro Inputs), entry 0x12 (Value))

UINT32

RO

0x0000:00, 16

1AA3:09

SubIndex 009

9. PDO Mapping entry (object 0x6050 (AI Gyro Inputs), entry 0x12 (Value))

UINT32

RO

0x6050:12, 32

Index 1AA4 AI Gyro Z TxPDO-Map Samples 1 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1AA4:0

AI Gyro Z TxPDO-Map Samples 1 (Real32)

PDO Mapping TxPDO 165

UINT8

RO

0x01 (1dec)

1AA4:01

SubIndex 001

1. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6053:01, 32

Index 1AA5 AI Gyro Z TxPDO-Map Samples 1

Index (hex)

Name

Meaning

Data type

Flags

Default

1AA5:0

AI Gyro Z TxPDO-Map Samples 1

PDO Mapping TxPDO 166

UINT8

RO

0x01 (1dec)

1AA5:01

SubIndex 001

1. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x01 (Sample))

UINT32

RO

0x6051:01, 32

Index 1AA6 AI Gyro Z TxPDO-Map Samples 2 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1AA6:0

AI Gyro Z TxPDO-Map Samples 2 (Real32)

PDO Mapping TxPDO 167

UINT8

RO

0x02 (2dec)

1AA6:01

SubIndex 001

1. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6053:01, 32

1AA6:02

SubIndex 002

2. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6053:02, 32

Index 1AA7 AI Gyro Z TxPDO-Map Samples 2

Index (hex)

Name

Meaning

Data type

Flags

Default

1AA7:0

AI Gyro Z TxPDO-Map Samples 2

PDO Mapping TxPDO 168

UINT8

RO

0x02 (2dec)

1AA7:01

SubIndex 001

1. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x01 (Sample))

UINT32

RO

0x6051:01, 32

1AA7:02

SubIndex 002

2. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x02 (Sample))

UINT32

RO

0x6051:02, 32

Index 1AA8 AI Gyro Z TxPDO-Map Samples 4 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1AA8:0

AI Gyro Z TxPDO-Map Samples 4 (Real32)

PDO Mapping TxPDO 169

UINT8

RO

0x04 (4dec)

1AA8:01

SubIndex 001

1. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6053:01, 32

1AA8:02

SubIndex 002

2. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6053:02, 32

1AA8:03

SubIndex 003

3. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6053:03, 32

1AA8:04

SubIndex 004

4. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6053:04, 32

Index 1AA9 AI Gyro Z TxPDO-Map Samples 4

Index (hex)

Name

Meaning

Data type

Flags

Default

1AA9:0

AI Gyro Z TxPDO-Map Samples 4

PDO Mapping TxPDO 170

UINT8

RO

0x04 (4dec)

1AA9:01

SubIndex 001

1. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x01 (Sample))

UINT32

RO

0x6051:01, 32

1AA9:02

SubIndex 002

2. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x02 (Sample))

UINT32

RO

0x6051:02, 32

1AA9:03

SubIndex 003

3. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x03 (Sample))

UINT32

RO

0x6051:03, 32

1AA9:04

SubIndex 004

4. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x04 (Sample))

UINT32

RO

0x6051:04, 32

Index 1AAA AI Gyro Z TxPDO-Map Samples 8 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1AAA:0

AI Gyro Z TxPDO-Map Samples 8 (Real32)

PDO Mapping TxPDO 171

UINT8

RO

0x08 (8dec)

1AAA:01

SubIndex 001

1. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6053:01, 32

1AAA:02

SubIndex 002

2. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6053:02, 32

1AAA:03

SubIndex 003

3. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6053:03, 32

1AAA:04

SubIndex 004

4. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6053:04, 32

1AAA:05

SubIndex 005

5. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x05 (Sample))

UINT32

RO

0x6053:05, 32

1AAA:06

SubIndex 006

6. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x06 (Sample))

UINT32

RO

0x6053:06, 32

1AAA:07

SubIndex 007

7. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x07 (Sample))

UINT32

RO

0x6053:07, 32

1AAA:08

SubIndex 008

8. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x08 (Sample))

UINT32

RO

0x6053:08, 32

Index 1AAB AI Gyro Z TxPDO-Map Samples 8

Index (hex)

Name

Meaning

Data type

Flags

Default

1AAB:0

AI Gyro Z TxPDO-Map Samples 8

PDO Mapping TxPDO 172

UINT8

RO

0x08 (8dec)

1AAB:01

SubIndex 001

1. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x01 (Sample))

UINT32

RO

0x6051:01, 32

1AAB:02

SubIndex 002

2. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x02 (Sample))

UINT32

RO

0x6051:02, 32

1AAB:03

SubIndex 003

3. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x03 (Sample))

UINT32

RO

0x6051:03, 32

1AAB:04

SubIndex 004

4. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x04 (Sample))

UINT32

RO

0x6051:04, 32

1AAB:05

SubIndex 005

5. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x05 (Sample))

UINT32

RO

0x6051:05, 32

1AAB:06

SubIndex 006

6. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x06 (Sample))

UINT32

RO

0x6051:06, 32

1AAB:07

SubIndex 007

7. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x07 (Sample))

UINT32

RO

0x6051:07, 32

1AAB:08

SubIndex 008

8. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x08 (Sample))

UINT32

RO

0x6051:08, 32

Index 1AAC AI Gyro Z TxPDO-Map Samples 10 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1AAC:0

AI Gyro Z TxPDO-Map Samples 10 (Real32)

PDO Mapping TxPDO 173

UINT8

RO

0x0A (10dec)

1AAC:01

SubIndex 001

1. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6053:01, 32

1AAC:02

SubIndex 002

2. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6053:02, 32

1AAC:03

SubIndex 003

3. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6053:03, 32

1AAC:04

SubIndex 004

4. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6053:04, 32

1AAC:05

SubIndex 005

5. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x05 (Sample))

UINT32

RO

0x6053:05, 32

1AAC:06

SubIndex 006

6. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x06 (Sample))

UINT32

RO

0x6053:06, 32

1AAC:07

SubIndex 007

7. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x07 (Sample))

UINT32

RO

0x6053:07, 32

1AAC:08

SubIndex 008

8. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x08 (Sample))

UINT32

RO

0x6053:08, 32

1AAC:09

SubIndex 009

9. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x09 (Sample))

UINT32

RO

0x6053:09, 32

1AAC:0A

SubIndex 010

10. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x0A (Sample))

UINT32

RO

0x6053:0A, 32

Index 1AAD AI Gyro Z TxPDO-Map Samples 10

Index (hex)

Name

Meaning

Data type

Flags

Default

1AAD:0

AI Gyro Z TxPDO-Map Samples 10

PDO Mapping TxPDO 174

UINT8

RO

0x0A (10dec)

1AAD:01

SubIndex 001

1. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x01 (Sample))

UINT32

RO

0x6051:01, 32

1AAD:02

SubIndex 002

2. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x02 (Sample))

UINT32

RO

0x6051:02, 32

1AAD:03

SubIndex 003

3. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x03 (Sample))

UINT32

RO

0x6051:03, 32

1AAD:04

SubIndex 004

4. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x04 (Sample))

UINT32

RO

0x6051:04, 32

1AAD:05

SubIndex 005

5. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x05 (Sample))

UINT32

RO

0x6051:05, 32

1AAD:06

SubIndex 006

6. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x06 (Sample))

UINT32

RO

0x6051:06, 32

1AAD:07

SubIndex 007

7. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x07 (Sample))

UINT32

RO

0x6051:07, 32

1AAD:08

SubIndex 008

8. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x08 (Sample))

UINT32

RO

0x6051:08, 32

1AAD:09

SubIndex 009

9. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x09 (Sample))

UINT32

RO

0x6051:09, 32

1AAD:0A

SubIndex 010

10. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x0A (Sample))

UINT32

RO

0x6051:0A, 32

Index 1AAE AI Gyro Z TxPDO-Map Samples 16 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1AAE:0

AI Gyro Z TxPDO-Map Samples 16 (Real32)

PDO Mapping TxPDO 175

UINT8

RO

0x10 (16dec)

1AAE:01

SubIndex 001

1. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6053:01, 32

1AAE:02

SubIndex 002

2. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6053:02, 32

1AAE:03

SubIndex 003

3. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6053:03, 32

1AAE:04

SubIndex 004

4. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6053:04, 32

1AAE:05

SubIndex 005

5. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x05 (Sample))

UINT32

RO

0x6053:05, 32

1AAE:06

SubIndex 006

6. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x06 (Sample))

UINT32

RO

0x6053:06, 32

1AAE:07

SubIndex 007

7. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x07 (Sample))

UINT32

RO

0x6053:07, 32

1AAE:08

SubIndex 008

8. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x08 (Sample))

UINT32

RO

0x6053:08, 32

1AAE:09

SubIndex 009

9. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x09 (Sample))

UINT32

RO

0x6053:09, 32

1AAE:0A

SubIndex 010

10. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x0A (Sample))

UINT32

RO

0x6053:0A, 32

1AAE:0B

SubIndex 011

11. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x0B (Sample))

UINT32

RO

0x6053:0B, 32

1AAE:0C

SubIndex 012

12. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x0C (Sample))

UINT32

RO

0x6053:0C, 32

1AAE:0D

SubIndex 013

13. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x0D (Sample))

UINT32

RO

0x6053:0D, 32

1AAE:0E

SubIndex 014

14. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x0E (Sample))

UINT32

RO

0x6053:0E, 32

1AAE:0F

SubIndex 015

15. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x0F (Sample))

UINT32

RO

0x6053:0F, 32

1AAE:10

SubIndex 016

16. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x10 (Sample))

UINT32

RO

0x6053:10, 32

Index 1AAF AI Gyro Z TxPDO-Map Samples 16

Index (hex)

Name

Meaning

Data type

Flags

Default

1AAF:0

AI Gyro Z TxPDO-Map Samples 16

PDO Mapping TxPDO 176

UINT8

RO

0x10 (16dec)

1AAF:01

SubIndex 001

1. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x01 (Sample))

UINT32

RO

0x6051:01, 32

1AAF:02

SubIndex 002

2. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x02 (Sample))

UINT32

RO

0x6051:02, 32

1AAF:03

SubIndex 003

3. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x03 (Sample))

UINT32

RO

0x6051:03, 32

1AAF:04

SubIndex 004

4. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x04 (Sample))

UINT32

RO

0x6051:04, 32

1AAF:05

SubIndex 005

5. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x05 (Sample))

UINT32

RO

0x6051:05, 32

1AAF:06

SubIndex 006

6. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x06 (Sample))

UINT32

RO

0x6051:06, 32

1AAF:07

SubIndex 007

7. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x07 (Sample))

UINT32

RO

0x6051:07, 32

1AAF:08

SubIndex 008

8. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x08 (Sample))

UINT32

RO

0x6051:08, 32

1AAF:09

SubIndex 009

9. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x09 (Sample))

UINT32

RO

0x6051:09, 32

1AAF:0A

SubIndex 010

10. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x0A (Sample))

UINT32

RO

0x6051:0A, 32

1AAF:0B

SubIndex 011

11. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x0B (Sample))

UINT32

RO

0x6051:0B, 32

1AAF:0C

SubIndex 012

12. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x0C (Sample))

UINT32

RO

0x6051:0C, 32

1AAF:0D

SubIndex 013

13. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x0D (Sample))

UINT32

RO

0x6051:0D, 32

1AAF:0E

SubIndex 014

14. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x0E (Sample))

UINT32

RO

0x6051:0E, 32

1AAF:0F

SubIndex 015

15. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x0F (Sample))

UINT32

RO

0x6051:0F, 32

1AAF:10

SubIndex 016

16. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x10 (Sample))

UINT32

RO

0x6051:10, 32

Index 1AB0 AI Gyro Z TxPDO-Map Samples 20 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1AB0:0

AI Gyro Z TxPDO-Map Samples 20 (Real32)

PDO Mapping TxPDO 177

UINT8

RO

0x14 (20dec)

1AB0:01

SubIndex 001

1. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6053:01, 32

1AB0:02

SubIndex 002

2. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6053:02, 32

1AB0:03

SubIndex 003

3. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6053:03, 32

1AB0:04

SubIndex 004

4. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6053:04, 32

1AB0:05

SubIndex 005

5. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x05 (Sample))

UINT32

RO

0x6053:05, 32

1AB0:06

SubIndex 006

6. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x06 (Sample))

UINT32

RO

0x6053:06, 32

1AB0:07

SubIndex 007

7. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x07 (Sample))

UINT32

RO

0x6053:07, 32

1AB0:08

SubIndex 008

8. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x08 (Sample))

UINT32

RO

0x6053:08, 32

1AB0:09

SubIndex 009

9. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x09 (Sample))

UINT32

RO

0x6053:09, 32

1AB0:0A

SubIndex 010

10. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x0A (Sample))

UINT32

RO

0x6053:0A, 32

1AB0:0B

SubIndex 011

11. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x0B (Sample))

UINT32

RO

0x6053:0B, 32

1AB0:0C

SubIndex 012

12. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x0C (Sample))

UINT32

RO

0x6053:0C, 32

1AB0:0D

SubIndex 013

13. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x0D (Sample))

UINT32

RO

0x6053:0D, 32

1AB0:0E

SubIndex 014

14. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x0E (Sample))

UINT32

RO

0x6053:0E, 32

1AB0:0F

SubIndex 015

15. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x0F (Sample))

UINT32

RO

0x6053:0F, 32

1AB0:10

SubIndex 016

16. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x10 (Sample))

UINT32

RO

0x6053:10, 32

1AB0:11

SubIndex 017

17. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x11 (Sample))

UINT32

RO

0x6053:11, 32

1AB0:12

SubIndex 018

18. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x12 (Sample))

UINT32

RO

0x6053:12, 32

1AB0:13

SubIndex 019

19. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x13 (Sample))

UINT32

RO

0x6053:13, 32

1AB0:14

SubIndex 020

20. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x14 (Sample))

UINT32

RO

0x6053:14, 32

Index 1AB1 AI Gyro Z TxPDO-Map Samples 20

Index (hex)

Name

Meaning

Data type

Flags

Default

1AB1:0

AI Gyro Z TxPDO-Map Samples 20

PDO Mapping TxPDO 178

UINT8

RO

0x14 (20dec)

1AB1:01

SubIndex 001

1. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x01 (Sample))

UINT32

RO

0x6051:01, 32

1AB1:02

SubIndex 002

2. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x02 (Sample))

UINT32

RO

0x6051:02, 32

1AB1:03

SubIndex 003

3. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x03 (Sample))

UINT32

RO

0x6051:03, 32

1AB1:04

SubIndex 004

4. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x04 (Sample))

UINT32

RO

0x6051:04, 32

1AB1:05

SubIndex 005

5. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x05 (Sample))

UINT32

RO

0x6051:05, 32

1AB1:06

SubIndex 006

6. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x06 (Sample))

UINT32

RO

0x6051:06, 32

1AB1:07

SubIndex 007

7. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x07 (Sample))

UINT32

RO

0x6051:07, 32

1AB1:08

SubIndex 008

8. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x08 (Sample))

UINT32

RO

0x6051:08, 32

1AB1:09

SubIndex 009

9. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x09 (Sample))

UINT32

RO

0x6051:09, 32

1AB1:0A

SubIndex 010

10. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x0A (Sample))

UINT32

RO

0x6051:0A, 32

1AB1:0B

SubIndex 011

11. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x0B (Sample))

UINT32

RO

0x6051:0B, 32

1AB1:0C

SubIndex 012

12. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x0C (Sample))

UINT32

RO

0x6051:0C, 32

1AB1:0D

SubIndex 013

13. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x0D (Sample))

UINT32

RO

0x6051:0D, 32

1AB1:0E

SubIndex 014

14. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x0E (Sample))

UINT32

RO

0x6051:0E, 32

1AB1:0F

SubIndex 015

15. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x0F (Sample))

UINT32

RO

0x6051:0F, 32

1AB1:10

SubIndex 016

16. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x10 (Sample))

UINT32

RO

0x6051:10, 32

1AB1:11

SubIndex 017

17. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x11 (Sample))

UINT32

RO

0x6051:11, 32

1AB1:12

SubIndex 018

18. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x12 (Sample))

UINT32

RO

0x6051:12, 32

1AB1:13

SubIndex 019

19. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x13 (Sample))

UINT32

RO

0x6051:13, 32

1AB1:14

SubIndex 020

20. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x14 (Sample))

UINT32

RO

0x6051:14, 32

Index 1AB2 AI Gyro Z TxPDO-Map Samples 40 (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1AB2:0

AI Gyro Z TxPDO-Map Samples 40 (Real32)

PDO Mapping TxPDO 179

UINT8

RO

0x28 (40dec)

1AB2:01

SubIndex 001

1. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x01 (Sample))

UINT32

RO

0x6053:01, 32

1AB2:02

SubIndex 002

2. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x02 (Sample))

UINT32

RO

0x6053:02, 32

1AB2:03

SubIndex 003

3. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x03 (Sample))

UINT32

RO

0x6053:03, 32

1AB2:04

SubIndex 004

4. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x04 (Sample))

UINT32

RO

0x6053:04, 32

1AB2:05

SubIndex 005

5. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x05 (Sample))

UINT32

RO

0x6053:05, 32

1AB2:06

SubIndex 006

6. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x06 (Sample))

UINT32

RO

0x6053:06, 32

1AB2:07

SubIndex 007

7. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x07 (Sample))

UINT32

RO

0x6053:07, 32

1AB2:08

SubIndex 008

8. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x08 (Sample))

UINT32

RO

0x6053:08, 32

1AB2:09

SubIndex 009

9. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x09 (Sample))

UINT32

RO

0x6053:09, 32

1AB2:0A

SubIndex 010

10. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x0A (Sample))

UINT32

RO

0x6053:0A, 32

1AB2:0B

SubIndex 011

11. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x0B (Sample))

UINT32

RO

0x6053:0B, 32

1AB2:0C

SubIndex 012

12. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x0C (Sample))

UINT32

RO

0x6053:0C, 32

1AB2:0D

SubIndex 013

13. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x0D (Sample))

UINT32

RO

0x6053:0D, 32

1AB2:0E

SubIndex 014

14. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x0E (Sample))

UINT32

RO

0x6053:0E, 32

1AB2:0F

SubIndex 015

15. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x0F (Sample))

UINT32

RO

0x6053:0F, 32

1AB2:10

SubIndex 016

16. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x10 (Sample))

UINT32

RO

0x6053:10, 32

1AB2:11

SubIndex 017

17. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x11 (Sample))

UINT32

RO

0x6053:11, 32

1AB2:12

SubIndex 018

18. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x12 (Sample))

UINT32

RO

0x6053:12, 32

1AB2:13

SubIndex 019

19. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x13 (Sample))

UINT32

RO

0x6053:13, 32

1AB2:14

SubIndex 020

20. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x14 (Sample))

UINT32

RO

0x6053:14, 32

1AB2:15

SubIndex 021

21. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x15 (Sample))

UINT32

RO

0x6053:15, 32

1AB2:16

SubIndex 022

22. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x16 (Sample))

UINT32

RO

0x6053:16, 32

1AB2:17

SubIndex 023

23. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x17 (Sample))

UINT32

RO

0x6053:17, 32

1AB2:18

SubIndex 024

24. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x18 (Sample))

UINT32

RO

0x6053:18, 32

1AB2:19

SubIndex 025

25. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x19 (Sample))

UINT32

RO

0x6053:19, 32

1AB2:1A

SubIndex 026

26. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x1A (Sample))

UINT32

RO

0x6053:1A, 32

1AB2:1B

SubIndex 027

27. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x1B (Sample))

UINT32

RO

0x6053:1B, 32

1AB2:1C

SubIndex 028

28. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x1C (Sample))

UINT32

RO

0x6053:1C, 32

1AB2:1D

SubIndex 029

29. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x1D (Sample))

UINT32

RO

0x6053:1D, 32

Index (hex)

Name

Meaning

Data type

Flags

Default

1AB2:1E

SubIndex 030

30. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x1E (Sample))

UINT32

RO

0x6053:1E, 32

1AB2:1F

SubIndex 031

31. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x1F (Sample))

UINT32

RO

0x6053:1F, 32

1AB2:20

SubIndex 032

32. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x20 (Sample))

UINT32

RO

0x6053:20, 32

1AB2:21

SubIndex 033

33. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x21 (Sample))

UINT32

RO

0x6053:21, 32

1AB2:22

SubIndex 034

34. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x22 (Sample))

UINT32

RO

0x6053:22, 32

1AB2:23

SubIndex 035

35. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x23 (Sample))

UINT32

RO

0x6053:23, 32

1AB2:24

SubIndex 036

36. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x24 (Sample))

UINT32

RO

0x6053:24, 32

1AB2:25

SubIndex 037

37. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x25 (Sample))

UINT32

RO

0x6053:25, 32

1AB2:26

SubIndex 038

38. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x26 (Sample))

UINT32

RO

0x6053:26, 32

1AB2:27

SubIndex 039

39. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x27 (Sample))

UINT32

RO

0x6053:27, 32

1AB2:28

SubIndex 040

40. PDO Mapping entry (object 0x6053 (AI Gyro Samples (Real32)), entry 0x28 (Sample))

UINT32

RO

0x6053:28, 32

Index 1AB3 AI Gyro Z TxPDO-Map Samples 40

Index (hex)

Name

Meaning

Data type

Flags

Default

1AB3:0

AI Gyro Z TxPDO-Map Samples 40

PDO Mapping TxPDO 180

UINT8

RO

0x28 (40dec)

1AB3:01

SubIndex 001

1. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x01 (Sample))

UINT32

RO

0x6051:01, 32

1AB3:02

SubIndex 002

2. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x02 (Sample))

UINT32

RO

0x6051:02, 32

1AB3:03

SubIndex 003

3. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x03 (Sample))

UINT32

RO

0x6051:03, 32

1AB3:04

SubIndex 004

4. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x04 (Sample))

UINT32

RO

0x6051:04, 32

1AB3:05

SubIndex 005

5. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x05 (Sample))

UINT32

RO

0x6051:05, 32

1AB3:06

SubIndex 006

6. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x06 (Sample))

UINT32

RO

0x6051:06, 32

1AB3:07

SubIndex 007

7. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x07 (Sample))

UINT32

RO

0x6051:07, 32

1AB3:08

SubIndex 008

8. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x08 (Sample))

UINT32

RO

0x6051:08, 32

1AB3:09

SubIndex 009

9. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x09 (Sample))

UINT32

RO

0x6051:09, 32

1AB3:0A

SubIndex 010

10. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x0A (Sample))

UINT32

RO

0x6051:0A, 32

1AB3:0B

SubIndex 011

11. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x0B (Sample))

UINT32

RO

0x6051:0B, 32

1AB3:0C

SubIndex 012

12. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x0C (Sample))

UINT32

RO

0x6051:0C, 32

1AB3:0D

SubIndex 013

13. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x0D (Sample))

UINT32

RO

0x6051:0D, 32

Index (hex)

Name

Meaning

Data type

Flags

Default

1AB3:0E

SubIndex 014

14. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x0E (Sample))

UINT32

RO

0x6051:0E, 32

1AB3:0F

SubIndex 015

15. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x0F (Sample))

UINT32

RO

0x6051:0F, 32

1AB3:10

SubIndex 016

16. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x10 (Sample))

UINT32

RO

0x6051:10, 32

1AB3:11

SubIndex 017

17. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x11 (Sample))

UINT32

RO

0x6051:11, 32

1AB3:12

SubIndex 018

18. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x12 (Sample))

UINT32

RO

0x6051:12, 32

1AB3:13

SubIndex 019

19. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x13 (Sample))

UINT32

RO

0x6051:13, 32

1AB3:14

SubIndex 020

20. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x14 (Sample))

UINT32

RO

0x6051:14, 32

1AB3:15

SubIndex 021

21. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x15 (Sample))

UINT32

RO

0x6051:15, 32

1AB3:16

SubIndex 022

22. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x16 (Sample))

UINT32

RO

0x6051:16, 32

1AB3:17

SubIndex 023

23. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x17 (Sample))

UINT32

RO

0x6051:17, 32

1AB3:18

SubIndex 024

24. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x18 (Sample))

UINT32

RO

0x6051:18, 32

1AB3:19

SubIndex 025

25. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x19 (Sample))

UINT32

RO

0x6051:19, 32

1AB3:1A

SubIndex 026

26. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x1A (Sample))

UINT32

RO

0x6051:1A, 32

1AB3:1B

SubIndex 027

27. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x1B (Sample))

UINT32

RO

0x6051:1B, 32

1AB3:1C

SubIndex 028

28. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x1C (Sample))

UINT32

RO

0x6051:1C, 32

1AB3:1D

SubIndex 029

29. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x1D (Sample))

UINT32

RO

0x6051:1D, 32

1AB3:1E

SubIndex 030

30. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x1E (Sample))

UINT32

RO

0x6051:1E, 32

1AB3:1F

SubIndex 031

31. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x1F (Sample))

UINT32

RO

0x6051:1F, 32

1AB3:20

SubIndex 032

32. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x20 (Sample))

UINT32

RO

0x6051:20, 32

1AB3:21

SubIndex 033

33. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x21 (Sample))

UINT32

RO

0x6051:21, 32

1AB3:22

SubIndex 034

34. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x22 (Sample))

UINT32

RO

0x6051:22, 32

1AB3:23

SubIndex 035

35. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x23 (Sample))

UINT32

RO

0x6051:23, 32

1AB3:24

SubIndex 036

36. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x24 (Sample))

UINT32

RO

0x6051:24, 32

1AB3:25

SubIndex 037

37. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x25 (Sample))

UINT32

RO

0x6051:25, 32

1AB3:26

SubIndex 038

38. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x26 (Sample))

UINT32

RO

0x6051:26, 32

1AB3:27

SubIndex 039

39. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x27 (Sample))

UINT32

RO

0x6051:27, 32

1AB3:28

SubIndex 040

40. PDO Mapping entry (object 0x6051 (AI Gyro Samples), entry 0x28 (Sample))

UINT32

RO

0x6051:28, 32

Index 1AC0 AI Sensor Temperature TxPDO-Map (Real)

Index (hex)

Name

Meaning

Data type

Flags

Default

1AC0:0

AI Sensor Temperature TxPDO-Map (Real)

PDO Mapping TxPDO 193

UINT8

RO

0x06 (6dec)

1AC0:01

SubIndex 001

1. PDO Mapping entry (14 bits align)

UINT32

RO

0x0000:00, 13

1AC0:02

SubIndex 002

2. PDO Mapping entry (object 0x6060 (AI Temp Inputs), entry 0x0F (TxPDO State))

UINT32

RO

0x6060:0E, 1

1AC0:03

SubIndex 003

3. PDO Mapping entry (object 0x6060 (AI Temp Inputs), entry 0x10 (TxPDO Toggle))

UINT32

RO

0x6060:0F, 1

1AC0:04

SubIndex 004

4. PDO Mapping entry (16 bits align)

UINT32

RO

0x6060:10, 1

1AC0:05

SubIndex 005

5. PDO Mapping entry (object 0x6060 (AI Temp Inputs), entry 0x13 (Value (Real32)))

UINT32

RO

0x0000:00, 16

1AC0:06

SubIndex 006

6. PDO Mapping entry (object 0x6060 (AI Temp Inputs), entry 0x13 (Value (Real32)))

UINT32

RO

0x6060:13, 32

Index 1AC1 AI Sensor Temperature TxPDO-Map Int

Index (hex)

Name

Meaning

Data type

Flags

Default

1AC1:0

AI Sensor Temperature TxPDO-Map Int

PDO Mapping TxPDO 194

UINT8

RO

0x06 (6dec)

1AC1:01

SubIndex 001

1. PDO Mapping entry (14 bits align)

UINT32

RO

0x0000:00, 13

1AC1:02

SubIndex 002

2. PDO Mapping entry (object 0x6060 (AI Temp Inputs), entry 0x0F (TxPDO State))

UINT32

RO

0x6060:0E, 1

1AC1:03

SubIndex 003

3. PDO Mapping entry (object 0x6060 (AI Temp Inputs), entry 0x10 (TxPDO Toggle))

UINT32

RO

0x6060:0F, 1

1AC1:04

SubIndex 004

4. PDO Mapping entry (16 bits align)

UINT32

RO

0x6060:10, 1

1AC1:05

SubIndex 005

5. PDO Mapping entry (object 0x6060 (AI Temp Inputs), entry 0x12 (Value))

UINT32

RO

0x0000:00, 16

1AC1:06

SubIndex 006

6. PDO Mapping entry (object 0x6060 (AI Temp Inputs), entry 0x12 (Value))

UINT32

RO

0x6060:12, 32

Index 1C00 Sync manager type

Index (hex)

Name

Meaning

Data type

Flags

Default

1C00:0

Sync manager type

Using the Sync Managers

UINT8

RO

0x04 (4dec)

1C00:01

SubIndex 001

Sync-Manager Type Channel 1: Mailbox Write

UINT8

RO

0x01 (1dec)

1C00:02

SubIndex 002

Sync-Manager Type Channel 2: Mailbox Read

UINT8

RO

0x02 (2dec)

1C00:03

SubIndex 003

Sync-Manager Type Channel 3: Process Data Write (Outputs)

UINT8

RO

0x03 (3dec)

1C00:04

SubIndex 004

Sync-Manager Type Channel 4: Process Data Read (Inputs)

UINT8

RO

0x04 (4dec)

Index 1C12 RxPDO assign

Index (hex)

Name

Meaning

Data type

Flags

Default

1C12:0

RxPDO assign

PDO Assign Outputs

UINT8

RW

0x01 (1dec)

1C12:01

Subindex 001

1. allocated RxPDO (contains the index of the associated RxPDO mapping object)

UINT16

RW

0x1660 (5728dec)

1C12:02

Subindex 002

2. allocated RxPDO (contains the index of the associated RxPDO mapping object)

UINT16

RW

0x0000 (0dec)

Index 1C13 TxPDO assign

Index (hex)

Name

Meaning

Data type

Flags

Default

1C13:0

TxPDO assign

PDO Assign Inputs

UINT8

RW

0x0C (12dec)

1C13:01

Subindex 001

1. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x1A00 (6656dec)

1C13:02

Subindex 002

2. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x1A04 (6660dec)

1C13:03

Subindex 003

3. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x1A20 (6688dec)

1C13:04

Subindex 004

4. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x1A24 (6692dec)

1C13:05

Subindex 005

5. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x1A40 (6720dec)

1C13:06

Subindex 006

6. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x1A44 (6724dec)

1C13:07

Subindex 007

7. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x1A60 (6752dec)

1C13:08

Subindex 008

8. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x1A64 (6756dec)

1C13:09

Subindex 009

9. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x1A80 (6784dec)

1C13:0A

Subindex 010

10. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x1A84 (6788dec)

1C13:0B

Subindex 011

11. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x1AA0 (6816dec)

1C13:0C

Subindex 012

12. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x1AA4 (6820dec)

1C13:0D

Subindex 013

13. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:0E

Subindex 014

14. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:0F

Subindex 015

15. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:10

Subindex 016

16. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:11

Subindex 017

17. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:12

Subindex 018

18. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:13

Subindex 019

19. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:14

Subindex 020

20. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:15

Subindex 021

21. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:16

Subindex 022

22. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:17

Subindex 023

23. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:18

Subindex 024

24. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:19

Subindex 025

25. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:1A

Subindex 026

26. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:1B

Subindex 027

27. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:1C

Subindex 028

28. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:1D

Subindex 029

29. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

Index (hex)

Name

Meaning

Data type

Flags

Default

1C13:1E

Subindex 030

30. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:1F

Subindex 031

31. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:20

Subindex 032

32. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:21

Subindex 033

33. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:22

Subindex 034

34. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:23

Subindex 035

35. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:24

Subindex 036

36. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:25

Subindex 037

37. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:26

Subindex 038

38. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:27

Subindex 039

39. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:28

Subindex 040

40. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:29

Subindex 041

41. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:2A

Subindex 042

42. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:2B

Subindex 043

43. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:2C

Subindex 044

44. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:2D

Subindex 045

45. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:2E

Subindex 046

46. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:2F

Subindex 047

47. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:30

Subindex 048

48. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:31

Subindex 049

49. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:32

Subindex 050

50. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:33

Subindex 051

51. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:34

Subindex 052

52. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:35

Subindex 053

53. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:36

Subindex 054

54. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:37

Subindex 055

55. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:38

Subindex 056

56. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:39

Subindex 057

57. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:3A

Subindex 058

58. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:3B

Subindex 059

59. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:3C

Subindex 060

60. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:3D

Subindex 061

61. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:3E

Subindex 062

62. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:3F

Subindex 063

63. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:40

Subindex 064

64. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:41

Subindex 065

65. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:42

Subindex 066

66. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:43

Subindex 067

67. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:44

Subindex 068

68. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:45

Subindex 069

69. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:46

Subindex 070

70. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:47

Subindex 071

71. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:48

Subindex 072

72. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:49

Subindex 073

73. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:4A

Subindex 074

74. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:4B

Subindex 075

75. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:4C

Subindex 076

76. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:4D

Subindex 077

77. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:4E

Subindex 078

78. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:4F

Subindex 079

79. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:50

Subindex 080

80. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:51

Subindex 081

81. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:52

Subindex 082

82. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:53

Subindex 083

83. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:54

Subindex 084

84. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:55

Subindex 085

85. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:56

Subindex 086

86. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:57

Subindex 087

87. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:58

Subindex 088

88. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:59

Subindex 089

89. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:5A

Subindex 090

90. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:5B

Subindex 091

91. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:5C

Subindex 092

92. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:5D

Subindex 093

93. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:5E

Subindex 094

94. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:5F

Subindex 095

95. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:60

Subindex 096

96. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:61

Subindex 097

97. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:62

Subindex 098

98. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:63

Subindex 099

99. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:64

Subindex 100

100. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:65

Subindex 101

101. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:66

Subindex 102

102. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:67

Subindex 103

103. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:68

Subindex 104

104. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:69

Subindex 105

105. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:6A

Subindex 106

106. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:6B

Subindex 107

107. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:6C

Subindex 108

108. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:6D

Subindex 109

109. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:6E

Subindex 110

110. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:6F

Subindex 111

111. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:70

Subindex 112

112. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:71

Subindex 113

113. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:72

Subindex 114

114. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:73

Subindex 115

115. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:74

Subindex 116

116. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:75

Subindex 117

117. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:76

Subindex 118

118. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:77

Subindex 119

119. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:78

Subindex 120

120. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:79

Subindex 121

121. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:7A

Subindex 122

122. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

Index 1C32 SM output parameter

Index (hex)

Name

Meaning

Data type

Flags

Default

1C32:0

SM output parameter

Synchronization parameters for the outputs

UINT8

RO

0x20 (32dec)

1C32:01

Sync mode

Current synchronization mode:

  • 0: Free Run
  • 1: Synchron with SM 2 Event
  • 2: DC-Mode - Synchron with SYNC0 Event
  • 3: DC-Mode - Synchron with SYNC1 Event

UINT16

RW

0x0001 (1dec)

1C32:02

Cycle time

Cycle time (in ns):

  • Free Run: cycle time of the local timer
  • Synchron with SM 2 Event: cycle time of the master
  • DC-Mode: SYNC0/SYNC1 Cycle Time

UINT32

RW

0x000F4240 (1000000dec)

1C32:03

Shift time

Time between SYNC0 event and output of the outputs (in ns, DC mode only)

UINT32

RO

0x00000000 (0dec)

1C32:04

Sync modes supported

Sync modes supported:

  • Bit 0 = 1: Free Run is supported
  • Bit 1 = 1: Synchron with SM 2 Event is supported
  • Bit 2-3 = 01: DC-Mode is supported
  • Bit 4-5 = 10: Output Shift with SYNC1 Event (only DC mode)
  • Bit 14 = 1: dynamic times (measurement through writing of 1C32:08)
  • )

UINT16

RO

0x0813 (2067dec)

1C32:05

Minimum cycle time

Minimum cycle time (in ns)

UINT32

RO

0x0003D090 (250000dec)

1C32:06

Calc and copy time

Minimum time between SYNC0 and SYNC1 event (in ns, DC Mode only)

UINT32

RO

0x00000000 (0dec)

1C32:07

Minimum delay time

 

UINT32

RO

0x00000000 (0dec)

1C32:08

Get Cycle Time

 

  • 0: Measurement of the local cycle time is stopped
  • 1: Measurement of the local cycle time is started

UINT16

RW

0x0000 (0dec)

1C32:09

Maximum delay time

Time between SYNC1 event and output of the outputs (in ns, DC mode only)

UINT32

RO

0x00000000 (0dec)

1C32:0B

SM event missed counter

Number of missed SM events in OPERATIONAL (DC Mode only)

UINT16

RO

0x0000 (0dec)

1C32:0C

Cycle exceeded counter

Number of occasions the cycle time was exceeded in OPERATIONAL (cycle was not completed in time or the next cycle began too early)

UINT16

RO

0x0000 (0dec)

1C32:0D

Shift too short counter

Number of intervals between SYNC0 and SYNC1 events that are too short (DC Mode only)

UINT16

RO

0x0000 (0dec)

1C32:20

Sync error

The synchronization was not correct in the last cycle (outputs were output too late; DC Mode only)

BOOLEAN

RO

0x00 (0dec)

Index 1C33 SM input parameter

Index (hex)

Name

Meaning

Data type

Flags

Default

1C33:0

SM input parameter

Synchronization parameters for the inputs

UINT8

RO

0x20 (32dec)

1C33:01

Sync mode

Current synchronization mode:

  • 0: Free Run
  • 1: Synchron with SM 3 Event (no outputs available)
  • 2: DC - Synchron with SYNC0 Event
  • 3: DC - Synchron with SYNC1 Event
  • 34: Synchron with SM 2 Event (outputs available)

UINT16

RW

0x0022 (34dec)

1C33:02

Cycle time

as 1C32:02

UINT32

RW

0x000F4240 (1000000dec)

1C33:03

Shift time

Time between SYNC0 event and reading of the inputs (in ns, DC Mode only)

UINT32

RO

0x00000000 (0dec)

1C33:04

Sync modes supported

Sync modes supported:

  • Bit 0: Free Run is supported
  • Bit 1: Synchron with SM 2 Event is supported (outputs available)
  • Bit 1: Synchron with SM 3 Event is supported (no outputs available)
  • Bit 2-3 = 01: DC-Mode is supported
  • Bit 4-5 = 01: Input shift through local event (outputs available)
  • Bit 4-5 = 10: Input shift with SYNC1 event (no outputs available)
  • Bit 14 = 1: dynamic times (measurement through writing of 1C32:08 or 1C33:08)
  • )

UINT16

RO

0x0013 (19dec)

1C33:05

Minimum cycle time

as 1C32:05

UINT32

RO

0x0003D090 (250000dec)

1C33:06

Calc and copy time

Time between reading of the inputs and the inputs being available for the master (in ns, DC Mode only)

UINT32

RO

0x00000000 (0dec)

1C33:07

Minimum delay time

 

UINT32

RO

0x00000000 (0dec)

1C33:08

Get Cycle Time

as 1C32:08

UINT16

RW

0x0000 (0dec)

1C33:09

Maximum delay time

Time between SYNC1 event and reading of the inputs (in ns, DC Mode only)

UINT32

RO

0x00000000 (0dec)

1C33:0B

SM event missed counter

as 1C32:11

UINT16

RO

0x0000 (0dec)

1C33:0C

Cycle exceeded counter

as 1C32:12

UINT16

RO

0x0000 (0dec)

1C33:0D

Shift too short counter

as 1C32:13

UINT16

RO

0x0000 (0dec)

1C33:20

Sync error

as 1C32:32

BOOLEAN

RO

0x00 (0dec)