Profile-specific objects

6000 PWM Inputs Ch.1

Index (hex)

Name

Meaning

Data type

Flags

Default

6000:0

PWM Inputs Ch.1

 

USINT

RO

0x12 (18dec)

6000:05

Ready to Enable

-

BOOL

RO

-

6000:06

Warning

-

BOOL

RO

-

6000:07

Error

-

BOOL

RO

-

6000:0D

Diag

-

BOOL

RO

-

6000:10

TxPDO Toggle

-

BOOL

RO

-

6000:11

Info Data 1

-

INT

RO

-

6000:12

Info Data 2

-

INT

RO

-

6010 PWM Inputs Ch.2

Index (hex)

Name

Meaning

Data type

Flags

Default

6010:0

PWM Inputs Ch.2

 

USINT

RO

0x12 (18dec)

6010:05

Ready to Enable

-

BOOL

RO

-

6010:06

Warning

-

BOOL

RO

-

6010:07

Error

-

BOOL

RO

-

6010:0D

Diag

-

BOOL

RO

-

6010:10

TxPDO Toggle

-

BOOL

RO

-

6010:11

Info Data 1

-

INT

RO

-

6010:12

Info Data 2

-

INT

RO

-

6020 PWM Inputs Ch.3

Index (hex)

Name

Meaning

Data type

Flags

Default

6020:0

PWM Inputs Ch.3

 

USINT

RO

0x12 (18dec)

6020:05

Ready to Enable

-

BOOL

RO

-

6020:06

Warning

-

BOOL

RO

-

6020:07

Error

-

BOOL

RO

-

6020:0D

Diag

-

BOOL

RO

-

6020:10

TxPDO Toggle

-

BOOL

RO

-

6020:11

Info Data 1

-

INT

RO

-

6020:12

Info Data 2

-

INT

RO

-

6030 PWM Inputs Ch.4

Index (hex)

Name

Meaning

Data type

Flags

Default

6030:0

PWM Inputs Ch.4

 

USINT

RO

0x12 (18dec)

6030:05

Ready to Enable

-

BOOL

RO

-

6030:06

Warning

-

BOOL

RO

-

6030:07

Error

-

BOOL

RO

-

6030:0D

Diag

-

BOOL

RO

-

6030:10

TxPDO Toggle

-

BOOL

RO

-

6030:11

Info Data 1

-

INT

RO

-

6030:12

Info Data 2

-

INT

RO

-

7000 PWM Outputs Ch.1

Index (hex)

Name

Meaning

Data type

Flags

Default

7000:0

PWM Outputs Ch.1

 

USINT

RO

0x11 (17dec)

7000:01

Enable Dithering

-

BOOL

RO

-

7000:06

Enable

-

BOOL

RO

-

7000:07

Reset

-

BOOL

RO

-

7000:11

PWM Output

-

INT

RO

-

7010 PWM Outputs Ch.2

Index (hex)

Name

Meaning

Data type

Flags

Default

7010:0

PWM Outputs Ch.2

 

USINT

RO

0x11 (17dec)

7010:01

Enable Dithering

-

BOOL

RO

-

7010:06

Enable

-

BOOL

RO

-

7010:07

Reset

-

BOOL

RO

-

7010:11

PWM Output

-

INT

RO

-

7020 PWM Outputs Ch.3

Index (hex)

Name

Meaning

Data type

Flags

Default

7020:0

PWM Outputs Ch.3

 

USINT

RO

0x11 (17dec)

7020:01

Enable Dithering

-

BOOL

RO

-

7020:06

Enable

-

BOOL

RO

-

7020:07

Reset

-

BOOL

RO

-

7020:11

PWM Output

-

INT

RO

-

7030 PWM Outputs Ch.4

Index (hex)

Name

Meaning

Data type

Flags

Default

7030:0

PWM Outputs Ch.4

 

USINT

RO

0x11 (17dec)

7030:01

Enable Dithering

-

BOOL

RO

-

7030:06

Enable

-

BOOL

RO

-

7030:07

Reset

-

BOOL

RO

-

7030:11

PWM Output

-

INT

RO

-