Configuration objects

Index 8020 AI Settings Ch.1

Index (hex)

Name

Meaning

Data type

Flags

Default

8020:0

AI Settings Ch.1

 

UINT8

RO

0x18 (24dec)

8020:01

Enable user scale

 

BOOLEAN

RW

0x00 (0dec)

8020:0A

Enable user calibration

 

BOOLEAN

RW

0x00 (0dec)

8020:0B

Enable vendor calibration

 

BOOLEAN

RW

0x00 (0dec)

8020:11

User scale offset

 

INT16

RW

0x0000 (0dec)

8020:12

User scale gain

 

INT32

RW

0x02A00000 (44040192dec)

8020:17

User calibration offset

 

INT16

RW

0x0000 (0dec)

8020:18

User calibration gain

 

INT16

RW

0x0000 (0dec)

Index 802F AI Vendor data Ch.1

Index (hex)

Name

Meaning

Data type

Flags

Default

802F:0

AI Vendor data Ch.1

 

UINT8

RO

0x02 (2dec)

802F:01

Calibration Offset

 

INT16

RW

0x0000 (0dec)

802F:02

Calibration Gain

 

INT16

RW

0x0000 (0dec)

Index 8030 AI Settings Ch.2

Index (hex)

Name

Meaning

Data type

Flags

Default

8030:0

AI Settings Ch.2

 

UINT8

RO

0x18 (24dec)

8030:01

Enable user scale

 

BOOLEAN

RW

0x00 (0dec)

8030:0A

Enable user calibration

 

BOOLEAN

RW

0x00 (0dec)

8030:0B

Enable vendor calibration

 

BOOLEAN

RW

0x00 (0dec)

8030:11

User scale offset

 

INT16

RW

0x0000 (0dec)

8030:12

User scale gain

 

INT32

RW

0x02A00000 (44040192dec)

8030:17

User calibration offset

 

INT16

RW

0x0000 (0dec)

8030:18

User calibration gain

 

INT16

RW

0x0000 (0dec)

Index 803F AI Vendor data Ch.2

Index (hex)

Name

Meaning

Data type

Flags

Default

803F:0

AI Vendor data Ch.2

 

UINT8

RO

0x02 (2dec)

803F:01

Calibration Offset

 

INT16

RW

0x0000 (0dec)

803F:02

Calibration Gain

 

INT16

RW

0x0000 (0dec)

Index 8040 AI Settings Ch.3

Index (hex)

Name

Meaning

Data type

Flags

Default

8040:0

AI Settings Ch.3

 

UINT8

RO

0x18 (24dec)

8040:01

Enable user scale

 

BOOLEAN

RW

0x00 (0dec)

8040:0A

Enable user calibration

 

BOOLEAN

RW

0x00 (0dec)

8040:0B

Enable vendor calibration

 

BOOLEAN

RW

0x00 (0dec)

8040:11

User scale offset

 

INT16

RW

0x0000 (0dec)

8040:12

User scale gain

 

INT32

RW

0x02A00000 (44040192dec)

8040:17

User calibration offset

 

INT16

RW

0x0000 (0dec)

8040:18

User calibration gain

 

INT16

RW

0x0000 (0dec)

Index 804F AI Vendor data Ch.3

Index (hex)

Name

Meaning

Data type

Flags

Default

804F:0

AI Vendor data Ch.3

 

UINT8

RO

0x02 (2dec)

804F:01

Calibration Offset

 

INT16

RW

0x0000 (0dec)

804F:02

Calibration Gain

 

INT16

RW

0x0000 (0dec)

Index 8050 AI Settings Ch.4

Index (hex)

Name

Meaning

Data type

Flags

Default

8050:0

AI Settings Ch.4

 

UINT8

RO

0x18 (24dec)

8050:01

Enable user scale

 

BOOLEAN

RW

0x00 (0dec)

8050:0A

Enable user calibration

 

BOOLEAN

RW

0x00 (0dec)

8050:0B

Enable vendor calibration

 

BOOLEAN

RW

0x00 (0dec)

8050:11

User scale offset

 

INT16

RW

0x0000 (0dec)

8050:12

User scale gain

 

INT32

RW

0x02A00000 (44040192dec)

8050:17

User calibration offset

 

INT16

RW

0x0000 (0dec)

8050:18

User calibration gain

 

INT16

RW

0x0000 (0dec)

Index 805F AI Vendor data Ch.4

Index (hex)

Name

Meaning

Data type

Flags

Default

805F:0

AI Vendor data Ch.4

 

UINT8

RO

0x02 (2dec)

805F:01

Calibration Offset

 

INT16

RW

0x0000 (0dec)

805F:02

Calibration Gain

 

INT16

RW

0x0000 (0dec)

Index 8060 AI Settings Ch.5

Index (hex)

Name

Meaning

Data type

Flags

Default

8060:0

AI Settings Ch.5

 

UINT8

RO

0x18 (24dec)

8060:01

Enable user scale

 

BOOLEAN

RW

0x00 (0dec)

8060:0A

Enable user calibration

 

BOOLEAN

RW

0x00 (0dec)

8060:0B

Enable vendor calibration

 

BOOLEAN

RW

0x00 (0dec)

8060:11

User scale offset

 

INT16

RW

0x0000 (0dec)

8060:12

User scale gain

 

INT32

RW

0x02A00000 (44040192dec)

8060:17

User calibration offset

 

INT16

RW

0x0000 (0dec)

8060:18

User calibration gain

 

INT16

RW

0x0000 (0dec)

Index 806F AI Vendor data Ch.5

Index (hex)

Name

Meaning

Data type

Flags

Default

806F:0

AI Vendor data Ch.5

 

UINT8

RO

0x02 (2dec)

806F:01

Calibration Offset

 

INT16

RW

0x0000 (0dec)

806F:02

Calibration Gain

 

INT16

RW

0x0000 (0dec)

Index 8070 AI Settings Ch.6

Index (hex)

Name

Meaning

Data type

Flags

Default

8070:0

AI Settings Ch.6

 

UINT8

RO

0x18 (24dec)

8070:01

Enable user scale

 

BOOLEAN

RW

0x00 (0dec)

8070:0A

Enable user calibration

 

BOOLEAN

RW

0x00 (0dec)

8070:0B

Enable vendor calibration

 

BOOLEAN

RW

0x00 (0dec)

8070:11

User scale offset

 

INT16

RW

0x0000 (0dec)

8070:12

User scale gain

 

INT32

RW

0x02A00000 (44040192dec)

8070:17

User calibration offset

 

INT16

RW

0x0000 (0dec)

8070:18

User calibration gain

 

INT16

RW

0x0000 (0dec)

Index 807F AI Vendor data Ch.6

Index (hex)

Name

Meaning

Data type

Flags

Default

807F:0

AI Vendor data Ch.6

 

UINT8

RO

0x02 (2dec)

807F:01

Calibration Offset

 

INT16

RW

0x0000 (0dec)

807F:02

Calibration Gain

 

INT16

RW

0x0000 (0dec)

Index 8080 SAI Settings

Index (hex)

Name

Meaning

Data type

Flags

Default

8080:0

SAI Settings

 

UINT8

RO

0x11 (17dec)

8080:0D

Mode

permitted values:

UINT16

RW

0x0000 (0dec)

4

1 Hz

5

10 Hz

6

25 Hz

7

50 Hz

8

100 Hz

9

200 Hz

10

400 Hz

11

1600 Hz

12

5000 Hz

8080:11

Range

permitted values:

UINT16

 

RW

0x0000 (0dec)

3

+/- 2G

4

+/- 4G

5

+/-  8G

6

+/-16G