Configuring the process image
You can configure the process image by selecting a Predefined PDO Assignment.
The following Predefined PDO Assignments are available:
Predefined PDO Assignment | Activated channels | Timestamp technology | MTSF |
|---|---|---|---|
Multi-Timestamping 8 Ch. 10x | 1…8 | Multi-timestamp | 10 |
Multi-Timestamping 8 Ch. 5x | 1…8 | Multi-timestamp | 5 |
Multi-Timestamping 8 Ch. 2x | 1…8 | Multi-timestamp | 2 |
Multi-Timestamping 8 Ch. 1x (default) | 1…8 | Multi-timestamp | 1 |
Multi-Timestamping 4 Ch. 10x | 1…4 | Multi-timestamp | 10 |
Multi-Timestamping 4 Ch. 5x | 1…4 | Multi-timestamp | 5 |
Multi-Timestamping 4 Ch. 2x | 1…4 | Multi-timestamp | 2 |
Multi-Timestamping 4 Ch. 1x | 1…4 | Multi-timestamp | 1 |
Multi-Timestamping 2 Ch. 10x | 1…2 | Multi-timestamp | 10 |
Multi-Timestamping 2 Ch. 5x | 1…2 | Multi-timestamp | 5 |
Multi-Timestamping 2 Ch. 2x | 1…2 | Multi-timestamp | 2 |
Multi-Timestamping 2 Ch. 1x | 1…2 | Multi-timestamp | 1 |
Multi-Timestamping 1 Ch. 10x | 1 | Multi-timestamp | 10 |
Multi-Timestamping 1 Ch. 5x | 1 | Multi-timestamp | 5 |
Multi-Timestamping 1 Ch. 2x | 1 | Multi-timestamp | 2 |
Multi-Timestamping 1 Ch. 1x | 1 | Multi-timestamp | 1 |
Compatible 1 Ch. | 1 | Timestamp | - |
Compatible 2 Ch. | 1…2 | Timestamp | - |
Compatible 4 Ch. | 1…4 | Timestamp | - |
Compatible 8 Ch. | 1…8 | Timestamp | - |