Standard objects
Index 1000 Device type
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1000:0 | Device type | Device type of the EtherCAT slave: the Lo-Word contains the used CoE profile (5001). The Hi-Word contains the module profile according to the modular device profile. | UINT32 | RO | 0x00001389 (5001dec) |
Index 1008 Device name
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1008:0 | Device name | Device name of the EtherCAT slave | STRING | RO | 1) |
1) The default value corresponds to the product name, e.g.
- "ELM7211-0010"
- "ELM7211-9016"
- "ELM7222-9018"
- …
Index 1009 Hardware version
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1009:0 | Hardware version | Hardware version of the EtherCAT slave | STRING | RO |
|
Index 100A Software version
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
100A:0 | Software version | Firmware version of the EtherCAT slave | STRING | RO | 01 |
Index 100B Bootloader version
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
B100:0 | Bootloader version |
| STRING | RO | N/A |
Index 1011 Restore default parameters
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1011:0 | Restore default parameters | Restore default settings | UINT8 | RO | 0x01 (1dec) |
1011:01 | SubIndex 001 | If this object is set to "0x64616F6C" in the set value dialog, all backup objects are reset to their delivery state. | UINT32 | RW | 0x00000000 (0dec) |
Index 1018 Identity
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1018:0 | Identity | Information for identifying the slave | UINT8 | RO | 0x04 (4dec) |
1018:01 | Vendor ID | Vendor ID of the EtherCAT slave | UINT32 | RO | 0x00000002 (2dec) |
1018:02 | Product code | Product code of the EtherCAT slave | UINT32 | RO | 1) |
1018:03 | Revision | Revision number of the EtherCAT slave; the Low Word (bit 0-15) indicates the special terminal number, the High Word (bit 16-31) refers to the device description | UINT32 | RO | 0x00000000 (0dec) |
1018:04 | Serial number | Serial number of the EtherCAT slave; the Low Byte (bit 0-7) of the Low Word contains the year of production, the High Byte (bit 8-15) of the Low Word contains the week of production, the High Word (bit 16-31) is 0 | UINT32 | RO | 0x00000000 (0dec) |
1) The default value of "Product code" varies depending on the product:
- ELM7211-xxxx: 0x502274B9 (1344435385dec)
- ELM7212-xxxx: 0x502274C9 (1344435401dec)
- ELM7221-xxxx: 0x50227559 (1344435545dec)
- ELM7222-xxxx: 0x50227569 (1344435561dec)
- ELM7231-xxxx: 0x502275F9 (1344435705dec)
Index 10E2 Manufacturer-specific Identification Code
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
10E2:0 | Manufacturer-specific Identification Code |
| UINT8 | RO | 0x01 (1dec) |
10E2:01 | SubIndex 001 |
| STRING | RO |
|
Index 10F0 Backup parameter handling
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
10F00:01 | Checksum | Checksum across all backup entries of the EtherCAT slave | UINT32 | RO | 0x00000000 (0dec) |
Index 10F8 Timestamp Object
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
10F8:0 | Timestamp Object |
| UINT64 | RO |
|
Index 1420 DMC RxPDO-Par Outputs Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1420:0 | DMC RxPDO-Par Outputs Ch.1 | PDO Parameter RxPDO 33 | UINT8 | RO | 0x06 (6dec) |
1420:06 | Exclude RxPDOs | Specifies the RxPDOs (index of RxPDO mapping objects) that must not be transferred together with RxPDO 33 | OCTET-STRING[2] | RO | 21 16 |
Index 1421 DMC RxPDO-Par Outputs 32 Bit Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1421:0 | DMC RxPDO-Par Outputs 32 Bit Ch.1 | PDO Parameter RxPDO 34 | UINT8 | RO | 0x06 (6dec) |
1421:06 | Exclude RxPDOs | Specifies the RxPDOs (index of RxPDO mapping objects) that must not be transferred together with RxPDO 34 | OCTET-STRING[2] | RO | 20 16 |
Index 1460 DMC RxPDO-Par Outputs Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1460:0 | DMC RxPDO-Par Outputs Ch.2 | PDO Parameter RxPDO 97 | UINT8 | RO | 0x06 (6dec) |
1460:06 | Exclude RxPDOs | Specifies the RxPDOs (index of RxPDO mapping objects) that must not be transferred together with RxPDO 97 | OCTET-STRING[2] | RO | 61 16 |
Index 1461 DMC RxPDO-Par Outputs 32 Bit Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1461:0 | DMC RxPDO-Par Outputs 32 Bit Ch.2 | PDO Parameter RxPDO 98 | UINT8 | RO | 0x06 (6dec) |
1461:06 | Exclude RxPDOs | Specifies the RxPDOs (index of RxPDO mapping objects) that must not be transferred together with RxPDO 98 | OCTET-STRING[2] | RO | 60 16 |
Index 1600 FB RxPDO-Map Touch probe control Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1600:0 | FB RxPDO-Map Touch probe control Ch.1 | PDO Mapping RxPDO 1 | UINT8 | RO | 0x0C (12dec) |
1600:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7001 (FB Touch probe outputs Ch.1), entry 0x01 (TP1 Enable)) | UINT32 | RO | 0x7001:01, 1 |
1600:02 | SubIndex 002 | 2. PDO Mapping entry (object 0x7001 (FB Touch probe outputs Ch.1), entry 0x02 (TP1 Continous)) | UINT32 | RO | 0x7001:02, 1 |
1600:03 | SubIndex 003 | 3. PDO Mapping entry (object 0x7001 (FB Touch probe outputs Ch.1), entry 0x03 (TP1 Trigger mode)) | UINT32 | RO | 0x7001:03, 2 |
1600:04 | SubIndex 004 | 4. PDO Mapping entry (object 0x7001 (FB Touch probe outputs Ch.1), entry 0x05 (TP1 Enable pos edge)) | UINT32 | RO | 0x7001:05, 1 |
1600:05 | SubIndex 005 | 5. PDO Mapping entry (object 0x7001 (FB Touch probe outputs Ch.1), entry 0x06 (TP1 Enable neg edge)) | UINT32 | RO | 0x7001:06, 1 |
1600:06 | SubIndex 006 | 6. PDO Mapping entry (2 bits align) | UINT32 | RO | 0x0000:00, 2 |
1600:07 | SubIndex 007 | 7. PDO Mapping entry (object 0x7001 (FB Touch probe outputs Ch.1), entry 0x09 (TP2 Enable)) | UINT32 | RO | 0x7001:09, 1 |
1600:08 | SubIndex 008 | 8. PDO Mapping entry (object 0x7001 (FB Touch probe outputs Ch.1), entry 0x0A (TP2 Continous)) | UINT32 | RO | 0x7001:0A, 1 |
1600:09 | SubIndex 009 | 9. PDO Mapping entry (object 0x7001 (FB Touch probe outputs Ch.1), entry 0x0B (TP2 Trigger mode)) | UINT32 | RO | 0x7001:0B, 2 |
1600:0A | SubIndex 010 | 10. PDO Mapping entry (object 0x7001 (FB Touch probe outputs Ch.1), entry 0x0D (TP2 Enable pos edge)) | UINT32 | RO | 0x7001:0D, 1 |
1600:0B | SubIndex 011 | 11. PDO Mapping entry (object 0x7001 (FB Touch probe outputs Ch.1), entry 0x0E (TP2 Enable neg edge)) | UINT32 | RO | 0x7001:0E, 1 |
1600:0C | SubIndex 012 | 12. PDO Mapping entry (2 bits align) | UINT32 | RO | 0x0000:00, 2 |
Index 1610 DRV RxPDO-Map Controlword Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1610:0 | DRV RxPDO-Map Controlword Ch.1 | PDO Mapping RxPDO 17 | UINT8 | RO | 0x01 (1dec) |
1610:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7010 (DRV Outputs Ch.1), entry 0x01 (Controlword)) | UINT32 | RO | 0x7010:01, 16 |
Index 1611 DRV RxPDO-Map Target position Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1611:0 | DRV RxPDO-Map Target position Ch.1 | PDO Mapping RxPDO 18 | UINT8 | RO | 0x01 (1dec) |
1611:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7010 (DRV Outputs Ch.1), entry 0x05 (Target position)) | UINT32 | RO | 0x7010:05, 32 |
Index 1612 DRV RxPDO-Map Target velocity Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1612:0 | DRV RxPDO-Map Target velocity Ch.1 | PDO Mapping RxPDO 19 | UINT8 | RO | 0x01 (1dec) |
1612:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7010 (DRV Outputs Ch.1), entry 0x06 (Target velocity)) | UINT32 | RO | 0x7010:06, 32 |
Index 1613 DRV RxPDO-Map Target torque Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1613:0 | DRV RxPDO-Map Target torque Ch.1 | PDO Mapping RxPDO 20 | UINT8 | RO | 0x01 (1dec) |
1613:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7010 (DRV Outputs Ch.1), entry 0x09 (Target torque)) | UINT32 | RO | 0x7010:09, 16 |
Index 1614 DRV RxPDO-Map Commutation angle Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1614:0 | DRV RxPDO-Map Commutation angle Ch.1 | PDO Mapping RxPDO 21 | UINT8 | RO | 0x01 (1dec) |
1614:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7010 (DRV Outputs Ch.1), entry 0x0E (Commutation angle)) | UINT32 | RO | 0x7010:0E, 16 |
Index 1615 DRV RxPDO-Map Velocity offset Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1615:0 | DRV RxPDO-Map Velocity offset Ch.1 | PDO Mapping RxPDO 22 | UINT8 | RO | 0x01 (1dec) |
1615:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7010 (DRV Outputs Ch.1), entry 0x0F (Velocity offset)) | UINT32 | RO | 0x7010:0F, 32 |
Index 1616 DRV RxPDO-Map Torque offset Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1616:0 | DRV RxPDO-Map Torque offset Ch.1 | PDO Mapping RxPDO 23 | UINT8 | RO | 0x01 (1dec) |
1616:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7010 (DRV Outputs Ch.1), entry 0x0A (Torque offset)) | UINT32 | RO | 0x7010:0A, 16 |
Index 1617 DRV RxPDO-Map Torque limitation Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1617:0 | DRV RxPDO-Map Torque limitation Ch.1 | PDO Mapping RxPDO 24 | UINT8 | RO | 0x01 (1dec) |
1617:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7010 (DRV Outputs Ch.1), entry 0x0B (Torque limitation)) | UINT32 | RO | 0x7010:0B, 16 |
Index 1618 DRV RxPDO-Map Positive torque limit value Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1618:0 | DRV RxPDO-Map Positive torque limit value Ch.1 | PDO Mapping RxPDO 25 | UINT8 | RO | 0x01 (1dec) |
1618:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7010 (DRV Outputs Ch.1), entry 0x10 (Positive torque limit value)) | UINT32 | RO | 0x7010:10, 16 |
Index 1619 DRV RxPDO-Map Negative torque limit value Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1619:0 | DRV RxPDO-Map Negative torque limit value Ch.1 | PDO Mapping RxPDO 26 | UINT8 | RO | 0x01 (1dec) |
1619:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7010 (DRV Outputs Ch.1), entry 0x11 (Negative torque limit value)) | UINT32 | RO | 0x7010:11, 16 |
Index 161A DRV RxPDO-Map Modes of operation Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
161A:0 | DRV RxPDO-Map Modes of operation Ch.1 | PDO Mapping RxPDO 27 | UINT8 | RO | 0x01 (1dec) |
161A:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7010 (DRV Outputs Ch.1), entry 0x03 (Modes of operation)) | UINT32 | RO | 0x7010:03, 8 |
Index 161B DRV RxPDO-Map Low velocity limit value Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
B161:0 | DRV RxPDO-Map Low velocity limit value Ch.1 | PDO Mapping RxPDO 28 | UINT8 | RO | 0x01 (1dec) |
161B:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7010 (DRV Outputs Ch.1), entry 0x12 (Low velocity limit value)) | UINT32 | RO | 0x7010:12, 32 |
Index 161C DRV RxPDO-Map High velocity limit value Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
161C:0 | DRV RxPDO-Map High velocity limit value Ch.1 | PDO Mapping RxPDO 29 | UINT8 | RO | 0x01 (1dec) |
161C:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7010 (DRV Outputs Ch.1), entry 0x13 (High velocity limit value)) | UINT32 | RO | 0x7010:13, 32 |
Index 1620 DMC RxPDO-Map Outputs Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1620:0 | DMC RxPDO-Map Outputs Ch.1 | PDO Mapping RxPDO 33 | UINT8 | RO | 0x12 (18dec) |
1620:01 | SubIndex 001 | 1. PDO Mapping entry (1 bits align) | UINT32 | RO | 0x0000:00, 1 |
1620:02 | SubIndex 002 | 2. PDO Mapping entry (object 0x7020 (DMC Outputs Ch.1), entry 0x02 (DMC__FeedbackControl__Enable latch extern on positive edge)) | UINT32 | RO | 0x7020:02, 1 |
1620:03 | SubIndex 003 | 3. PDO Mapping entry (object 0x7020 (DMC Outputs Ch.1), entry 0x03 (DMC__FeedbackControl__Set counter)) | UINT32 | RO | 0x7020:03, 1 |
1620:04 | SubIndex 004 | 4. PDO Mapping entry (object 0x7020 (DMC Outputs Ch.1), entry 0x04 (DMC__FeedbackControl__Enable latch extern on negative edge)) | UINT32 | RO | 0x7020:04, 1 |
1620:05 | SubIndex 005 | 5. PDO Mapping entry (12 bits align) | UINT32 | RO | 0x0000:00, 12 |
1620:06 | SubIndex 006 | 6. PDO Mapping entry (object 0x7020 (DMC Outputs Ch.1), entry 0x11 (DMC__DriveControl__Enable)) | UINT32 | RO | 0x7020:11, 1 |
1620:07 | SubIndex 007 | 7. PDO Mapping entry (object 0x7020 (DMC Outputs Ch.1), entry 0x12 (DMC__DriveControl__Reset)) | UINT32 | RO | 0x7020:12, 1 |
1620:08 | SubIndex 008 | 8. PDO Mapping entry (14 bits align) | UINT32 | RO | 0x0000:00, 14 |
1620:09 | SubIndex 009 | 9. PDO Mapping entry (object 0x7020 (DMC Outputs Ch.1), entry 0x21 (DMC__PositioningControl__Execute)) | UINT32 | RO | 0x7020:21, 1 |
1620:0A | SubIndex 010 | 10. PDO Mapping entry (object 0x7020 (DMC Outputs Ch.1), entry 0x22 (DMC__PositioningControl__Emergency stop)) | UINT32 | RO | 0x7020:22, 1 |
1620:0B | SubIndex 011 | 11. PDO Mapping entry (14 bits align) | UINT32 | RO | 0x0000:00, 14 |
1620:0C | SubIndex 012 | 12. PDO Mapping entry (object 0x7020 (DMC Outputs Ch.1), entry 0x31 (DMC__Set counter value)) | UINT32 | RO | 0x7020:31, 64 |
1620:0D | SubIndex 013 | 13. PDO Mapping entry (object 0x7020 (DMC Outputs Ch.1), entry 0x32 (DMC__Target position)) | UINT32 | RO | 0x7020:32, 64 |
1620:0E | SubIndex 014 | 14. PDO Mapping entry (object 0x7020 (DMC Outputs Ch.1), entry 0x33 (DMC__Target velocity)) | UINT32 | RO | 0x7020:33, 16 |
1620:0F | SubIndex 015 | 15. PDO Mapping entry (object 0x7020 (DMC Outputs Ch.1), entry 0x34 (DMC__Start type)) | UINT32 | RO | 0x7020:34, 16 |
1620:10 | SubIndex 016 | 16. PDO Mapping entry (object 0x7020 (DMC Outputs Ch.1), entry 0x35 (DMC__Target acceleration)) | UINT32 | RO | 0x7020:35, 16 |
1620:11 | SubIndex 017 | 17. PDO Mapping entry (object 0x7020 (DMC Outputs Ch.1), entry 0x36 (DMC__Target deceleration)) | UINT32 | RO | 0x7020:36, 16 |
1620:12 | SubIndex 018 | 18. PDO Mapping entry (80 bits align) | UINT32 | RO | 0x0000:00, 80 |
Index 1621 DMC RxPDO-Map Outputs 32 Bit Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1621:0 | DMC RxPDO-Map Outputs 32 Bit Ch.1 | PDO Mapping RxPDO 34 | UINT8 | RO | 0x14 (20dec) |
1621:01 | SubIndex 001 | 1. PDO Mapping entry (1 bits align) | UINT32 | RO | 0x0000:00, 1 |
1621:02 | SubIndex 002 | 2. PDO Mapping entry (object 0x7020 (DMC Outputs Ch.1), entry 0x02 (DMC__FeedbackControl__Enable latch extern on positive edge)) | UINT32 | RO | 0x7020:02, 1 |
1621:03 | SubIndex 003 | 3. PDO Mapping entry (object 0x7020 (DMC Outputs Ch.1), entry 0x03 (DMC__FeedbackControl__Set counter)) | UINT32 | RO | 0x7020:03, 1 |
1621:04 | SubIndex 004 | 4. PDO Mapping entry (object 0x7020 (DMC Outputs Ch.1), entry 0x04 (DMC__FeedbackControl__Enable latch extern on negative edge)) | UINT32 | RO | 0x7020:04, 1 |
1621:05 | SubIndex 005 | 5. PDO Mapping entry (12 bits align) | UINT32 | RO | 0x0000:00, 12 |
1621:06 | SubIndex 006 | 6. PDO Mapping entry (object 0x7020 (DMC Outputs Ch.1), entry 0x11 (DMC__DriveControl__Enable)) | UINT32 | RO | 0x7020:11, 1 |
1621:07 | SubIndex 007 | 7. PDO Mapping entry (object 0x7020 (DMC Outputs Ch.1), entry 0x12 (DMC__DriveControl__Reset)) | UINT32 | RO | 0x7020:12, 1 |
1621:08 | SubIndex 008 | 8. PDO Mapping entry (14 bits align) | UINT32 | RO | 0x0000:00, 14 |
1621:09 | SubIndex 009 | 9. PDO Mapping entry (object 0x7020 (DMC Outputs Ch.1), entry 0x21 (DMC__PositioningControl__Execute)) | UINT32 | RO | 0x7020:21, 1 |
1621:0A | SubIndex 010 | 10. PDO Mapping entry (object 0x7020 (DMC Outputs Ch.1), entry 0x22 (DMC__PositioningControl__Emergency stop)) | UINT32 | RO | 0x7020:22, 1 |
1621:0B | SubIndex 011 | 11. PDO Mapping entry (14 bits align) | UINT32 | RO | 0x0000:00, 14 |
1621:0C | SubIndex 012 | 12. PDO Mapping entry (object 0x7020 (DMC Outputs Ch.1), entry 0x31 (DMC__Set counter value)) | UINT32 | RO | 0x7020:31, 32 |
1621:0D | SubIndex 013 | 13. PDO Mapping entry (32 bits align) | UINT32 | RO | 0x0000:00, 32 |
1621:0E | SubIndex 014 | 14. PDO Mapping entry (object 0x7020 (DMC Outputs Ch.1), entry 0x32 (DMC__Target position)) | UINT32 | RO | 0x7020:32, 32 |
1621:0F | SubIndex 015 | 15. PDO Mapping entry (32 bits align) | UINT32 | RO | 0x0000:00, 32 |
1621:10 | SubIndex 016 | 16. PDO Mapping entry (object 0x7020 (DMC Outputs Ch.1), entry 0x33 (DMC__Target velocity)) | UINT32 | RO | 0x7020:33, 16 |
1621:11 | SubIndex 017 | 17. PDO Mapping entry (object 0x7020 (DMC Outputs Ch.1), entry 0x34 (DMC__Start type)) | UINT32 | RO | 0x7020:34, 16 |
1621:12 | SubIndex 018 | 18. PDO Mapping entry (object 0x7020 (DMC Outputs Ch.1), entry 0x35 (DMC__Target acceleration)) | UINT32 | RO | 0x7020:35, 16 |
1621:13 | SubIndex 019 | 19. PDO Mapping entry (object 0x7020 (DMC Outputs Ch.1), entry 0x36 (DMC__Target deceleration)) | UINT32 | RO | 0x7020:36, 16 |
1621:14 | SubIndex 020 | 20. PDO Mapping entry (80 bits align) | UINT32 | RO | 0x0000:00, 80 |
Index 1640 FB RxPDO-Map Touch probe control Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1640:0 | FB RxPDO-Map Touch probe control Ch.2 | PDO Mapping RxPDO 65 | UINT8 | RO | 0x0C (12dec) |
1640:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7101 (FB Touch probe outputs Ch.2), entry 0x01 (TP1 Enable)) | UINT32 | RO | 0x7101:01, 1 |
1640:02 | SubIndex 002 | 2. PDO Mapping entry (object 0x7101 (FB Touch probe outputs Ch.2), entry 0x02 (TP1 Continous)) | UINT32 | RO | 0x7101:02, 1 |
1640:03 | SubIndex 003 | 3. PDO Mapping entry (object 0x7101 (FB Touch probe outputs Ch.2), entry 0x03 (TP1 Trigger mode)) | UINT32 | RO | 0x7101:03, 2 |
1640:04 | SubIndex 004 | 4. PDO Mapping entry (object 0x7101 (FB Touch probe outputs Ch.2), entry 0x05 (TP1 Enable pos edge)) | UINT32 | RO | 0x7101:05, 1 |
1640:05 | SubIndex 005 | 5. PDO Mapping entry (object 0x7101 (FB Touch probe outputs Ch.2), entry 0x06 (TP1 Enable neg edge)) | UINT32 | RO | 0x7101:06, 1 |
1640:06 | SubIndex 006 | 6. PDO Mapping entry (2 bits align) | UINT32 | RO | 0x0000:00, 2 |
1640:07 | SubIndex 007 | 7. PDO Mapping entry (object 0x7101 (FB Touch probe outputs Ch.2), entry 0x09 (TP2 Enable)) | UINT32 | RO | 0x7101:09, 1 |
1640:08 | SubIndex 008 | 8. PDO Mapping entry (object 0x7101 (FB Touch probe outputs Ch.2), entry 0x0A (TP2 Continous)) | UINT32 | RO | 0x7101:0A, 1 |
1640:09 | SubIndex 009 | 9. PDO Mapping entry (object 0x7101 (FB Touch probe outputs Ch.2), entry 0x0B (TP2 Trigger mode)) | UINT32 | RO | 0x7101:0B, 2 |
1640:0A | SubIndex 010 | 10. PDO Mapping entry (object 0x7101 (FB Touch probe outputs Ch.2), entry 0x0D (TP2 Enable pos edge)) | UINT32 | RO | 0x7101:0D, 1 |
1640:0B | SubIndex 011 | 11. PDO Mapping entry (object 0x7101 (FB Touch probe outputs Ch.2), entry 0x0E (TP2 Enable neg edge)) | UINT32 | RO | 0x7101:0E, 1 |
1640:0C | SubIndex 012 | 12. PDO Mapping entry (2 bits align) | UINT32 | RO | 0x0000:00, 2 |
Index 1650 DRV RxPDO-Map Controlword Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1650:0 | DRV RxPDO-Map Controlword Ch.2 | PDO Mapping RxPDO 81 | UINT8 | RO | 0x01 (1dec) |
1650:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7110 (DRV Outputs Ch.2), entry 0x01 (Controlword)) | UINT32 | RO | 0x7110:01, 16 |
Index 1651 DRV RxPDO-Map Target position Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1651:0 | DRV RxPDO-Map Target position Ch.2 | PDO Mapping RxPDO 82 | UINT8 | RO | 0x01 (1dec) |
1651:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7110 (DRV Outputs Ch.2), entry 0x05 (Target position)) | UINT32 | RO | 0x7110:05, 32 |
Index 1652 DRV RxPDO-Map Target velocity Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1652:0 | DRV RxPDO-Map Target velocity Ch.2 | PDO Mapping RxPDO 83 | UINT8 | RO | 0x01 (1dec) |
1652:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7110 (DRV Outputs Ch.2), entry 0x06 (Target velocity)) | UINT32 | RO | 0x7110:06, 32 |
Index 1653 DRV RxPDO-Map Target torque Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1653:0 | DRV RxPDO-Map Target torque Ch.2 | PDO Mapping RxPDO 84 | UINT8 | RO | 0x01 (1dec) |
1653:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7110 (DRV Outputs Ch.2), entry 0x09 (Target torque)) | UINT32 | RO | 0x7110:09, 16 |
Index 1654 DRV RxPDO-Map Commutation angle Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1654:0 | DRV RxPDO-Map Commutation angle Ch.2 | PDO Mapping RxPDO 85 | UINT8 | RO | 0x01 (1dec) |
1654:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7110 (DRV Outputs Ch.2), entry 0x0E (Commutation angle)) | UINT32 | RO | 0x7110:0E, 16 |
Index 1655 DRV RxPDO-Map Velocity offset Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1655:0 | DRV RxPDO-Map Velocity offset Ch.2 | PDO Mapping RxPDO 86 | UINT8 | RO | 0x01 (1dec) |
1655:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7110 (DRV Outputs Ch.2), entry 0x0F (Velocity offset)) | UINT32 | RO | 0x7110:0F, 32 |
Index 1656 DRV RxPDO-Map Torque offset Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1656:0 | DRV RxPDO-Map Torque offset Ch.2 | PDO Mapping RxPDO 87 | UINT8 | RO | 0x01 (1dec) |
1656:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7110 (DRV Outputs Ch.2), entry 0x0A (Torque offset)) | UINT32 | RO | 0x7110:0A, 16 |
Index 1657 DRV RxPDO-Map Torque limitation Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1657:0 | DRV RxPDO-Map Torque limitation Ch.2 | PDO Mapping RxPDO 88 | UINT8 | RO | 0x01 (1dec) |
1657:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7110 (DRV Outputs Ch.2), entry 0x0B (Torque limitation)) | UINT32 | RO | 0x7110:0B, 16 |
Index 1658 DRV RxPDO-Map Positive torque limit value Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1658:0 | DRV RxPDO-Map Positive torque limit value Ch.2 | PDO Mapping RxPDO 89 | UINT8 | RO | 0x01 (1dec) |
1658:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7110 (DRV Outputs Ch.2), entry 0x10 (Positive torque limit value)) | UINT32 | RO | 0x7110:10, 16 |
Index 1659 DRV RxPDO-Map Negative torque limit value Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1659:0 | DRV RxPDO-Map Negative torque limit value Ch.2 | PDO Mapping RxPDO 90 | UINT8 | RO | 0x01 (1dec) |
1659:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7110 (DRV Outputs Ch.2), entry 0x11 (Negative torque limit value)) | UINT32 | RO | 0x7110:11, 16 |
Index 165A DRV RxPDO-Map Modes of operation Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
165A:0 | DRV RxPDO-Map Modes of operation Ch.2 | PDO Mapping RxPDO 91 | UINT8 | RO | 0x01 (1dec) |
165A:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7110 (DRV Outputs Ch.2), entry 0x03 (Modes of operation)) | UINT32 | RO | 0x7110:03, 8 |
Index 165B DRV RxPDO-Map Low velocity limit value Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
B165:0 | DRV RxPDO-Map Low velocity limit value Ch.2 | PDO Mapping RxPDO 92 | UINT8 | RO | 0x01 (1dec) |
165B:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7110 (DRV Outputs Ch.2), entry 0x12 (Low velocity limit value)) | UINT32 | RO | 0x7110:12, 32 |
Index 165C DRV RxPDO-Map High velocity limit value Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
165C:0 | DRV RxPDO-Map High velocity limit value Ch.2 | PDO Mapping RxPDO 93 | UINT8 | RO | 0x01 (1dec) |
165C:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7110 (DRV Outputs Ch.2), entry 0x13 (High velocity limit value)) | UINT32 | RO | 0x7110:13, 32 |
Index 1660 DMC RxPDO-Map Outputs Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1660:0 | DMC RxPDO-Map Outputs Ch.2 | PDO Mapping RxPDO 97 | UINT8 | RO | 0x12 (18dec) |
1660:01 | SubIndex 001 | 1. PDO Mapping entry (1 bits align) | UINT32 | RO | 0x0000:00, 1 |
1660:02 | SubIndex 002 | 2. PDO Mapping entry (object 0x7120 (DMC Outputs Ch.2), entry 0x02 (DMC__FeedbackControl__Enable latch extern on positive edge)) | UINT32 | RO | 0x7120:02, 1 |
1660:03 | SubIndex 003 | 3. PDO Mapping entry (object 0x7120 (DMC Outputs Ch.2), entry 0x03 (DMC__FeedbackControl__Set counter)) | UINT32 | RO | 0x7120:03, 1 |
1660:04 | SubIndex 004 | 4. PDO Mapping entry (object 0x7120 (DMC Outputs Ch.2), entry 0x04 (DMC__FeedbackControl__Enable latch extern on negative edge)) | UINT32 | RO | 0x7120:04, 1 |
1660:05 | SubIndex 005 | 5. PDO Mapping entry (12 bits align) | UINT32 | RO | 0x0000:00, 12 |
1660:06 | SubIndex 006 | 6. PDO Mapping entry (object 0x7120 (DMC Outputs Ch.2), entry 0x11 (DMC__DriveControl__Enable)) | UINT32 | RO | 0x7120:11, 1 |
1660:07 | SubIndex 007 | 7. PDO Mapping entry (object 0x7120 (DMC Outputs Ch.2), entry 0x12 (DMC__DriveControl__Reset)) | UINT32 | RO | 0x7120:12, 1 |
1660:08 | SubIndex 008 | 8. PDO Mapping entry (14 bits align) | UINT32 | RO | 0x0000:00, 14 |
1660:09 | SubIndex 009 | 9. PDO Mapping entry (object 0x7120 (DMC Outputs Ch.2), entry 0x21 (DMC__PositioningControl__Execute)) | UINT32 | RO | 0x7120:21, 1 |
1660:0A | SubIndex 010 | 10. PDO Mapping entry (object 0x7120 (DMC Outputs Ch.2), entry 0x22 (DMC__PositioningControl__Emergency stop)) | UINT32 | RO | 0x7120:22, 1 |
1660:0B | SubIndex 011 | 11. PDO Mapping entry (14 bits align) | UINT32 | RO | 0x0000:00, 14 |
1660:0C | SubIndex 012 | 12. PDO Mapping entry (object 0x7120 (DMC Outputs Ch.2), entry 0x31 (DMC__Set counter value)) | UINT32 | RO | 0x7120:31, 64 |
1660:0D | SubIndex 013 | 13. PDO Mapping entry (object 0x7120 (DMC Outputs Ch.2), entry 0x32 (DMC__Target position)) | UINT32 | RO | 0x7120:32, 64 |
1660:0E | SubIndex 014 | 14. PDO Mapping entry (object 0x7120 (DMC Outputs Ch.2), entry 0x33 (DMC__Target velocity)) | UINT32 | RO | 0x7120:33, 16 |
1660:0F | SubIndex 015 | 15. PDO Mapping entry (object 0x7120 (DMC Outputs Ch.2), entry 0x34 (DMC__Start type)) | UINT32 | RO | 0x7120:34, 16 |
1660:10 | SubIndex 016 | 16. PDO Mapping entry (object 0x7120 (DMC Outputs Ch.2), entry 0x35 (DMC__Target acceleration)) | UINT32 | RO | 0x7120:35, 16 |
1660:11 | SubIndex 017 | 17. PDO Mapping entry (object 0x7120 (DMC Outputs Ch.2), entry 0x36 (DMC__Target deceleration)) | UINT32 | RO | 0x7120:36, 16 |
1660:12 | SubIndex 018 | 18. PDO Mapping entry (80 bits align) | UINT32 | RO | 0x0000:00, 80 |
Index 1661 DMC RxPDO-Map Outputs 32 Bit Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1661:0 | DMC RxPDO-Map Outputs 32 Bit Ch.2 | PDO Mapping RxPDO 98 | UINT8 | RO | 0x14 (20dec) |
1661:01 | SubIndex 001 | 1. PDO Mapping entry (1 bits align) | UINT32 | RO | 0x0000:00, 1 |
1661:02 | SubIndex 002 | 2. PDO Mapping entry (object 0x7120 (DMC Outputs Ch.2), entry 0x02 (DMC__FeedbackControl__Enable latch extern on positive edge)) | UINT32 | RO | 0x7120:02, 1 |
1661:03 | SubIndex 003 | 3. PDO Mapping entry (object 0x7120 (DMC Outputs Ch.2), entry 0x03 (DMC__FeedbackControl__Set counter)) | UINT32 | RO | 0x7120:03, 1 |
1661:04 | SubIndex 004 | 4. PDO Mapping entry (object 0x7120 (DMC Outputs Ch.2), entry 0x04 (DMC__FeedbackControl__Enable latch extern on negative edge)) | UINT32 | RO | 0x7120:04, 1 |
1661:05 | SubIndex 005 | 5. PDO Mapping entry (12 bits align) | UINT32 | RO | 0x0000:00, 12 |
1661:06 | SubIndex 006 | 6. PDO Mapping entry (object 0x7120 (DMC Outputs Ch.2), entry 0x11 (DMC__DriveControl__Enable)) | UINT32 | RO | 0x7120:11, 1 |
1661:07 | SubIndex 007 | 7. PDO Mapping entry (object 0x7120 (DMC Outputs Ch.2), entry 0x12 (DMC__DriveControl__Reset)) | UINT32 | RO | 0x7120:12, 1 |
1661:08 | SubIndex 008 | 8. PDO Mapping entry (14 bits align) | UINT32 | RO | 0x0000:00, 14 |
1661:09 | SubIndex 009 | 9. PDO Mapping entry (object 0x7120 (DMC Outputs Ch.2), entry 0x21 (DMC__PositioningControl__Execute)) | UINT32 | RO | 0x7120:21, 1 |
1661:0A | SubIndex 010 | 10. PDO Mapping entry (object 0x7120 (DMC Outputs Ch.2), entry 0x22 (DMC__PositioningControl__Emergency stop)) | UINT32 | RO | 0x7120:22, 1 |
1661:0B | SubIndex 011 | 11. PDO Mapping entry (14 bits align) | UINT32 | RO | 0x0000:00, 14 |
1661:0C | SubIndex 012 | 12. PDO Mapping entry (object 0x7120 (DMC Outputs Ch.2), entry 0x31 (DMC__Set counter value)) | UINT32 | RO | 0x7120:31, 32 |
1661:0D | SubIndex 013 | 13. PDO Mapping entry (32 bits align) | UINT32 | RO | 0x0000:00, 32 |
1661:0E | SubIndex 014 | 14. PDO Mapping entry (object 0x7120 (DMC Outputs Ch.2), entry 0x32 (DMC__Target position)) | UINT32 | RO | 0x7120:32, 32 |
1661:0F | SubIndex 015 | 15. PDO Mapping entry (32 bits align) | UINT32 | RO | 0x0000:00, 32 |
1661:10 | SubIndex 016 | 16. PDO Mapping entry (object 0x7120 (DMC Outputs Ch.2), entry 0x33 (DMC__Target velocity)) | UINT32 | RO | 0x7120:33, 16 |
1661:11 | SubIndex 017 | 17. PDO Mapping entry (object 0x7120 (DMC Outputs Ch.2), entry 0x34 (DMC__Start type)) | UINT32 | RO | 0x7120:34, 16 |
1661:12 | SubIndex 018 | 18. PDO Mapping entry (object 0x7120 (DMC Outputs Ch.2), entry 0x35 (DMC__Target acceleration)) | UINT32 | RO | 0x7120:35, 16 |
1661:13 | SubIndex 019 | 19. PDO Mapping entry (object 0x7120 (DMC Outputs Ch.2), entry 0x36 (DMC__Target deceleration)) | UINT32 | RO | 0x7120:36, 16 |
1661:14 | SubIndex 020 | 20. PDO Mapping entry (80 bits align) | UINT32 | RO | 0x0000:00, 80 |
Index 1820 DMC TxPDO-Par Inputs Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1820:0 | DMC TxPDO-Par Inputs Ch.1 | PDO parameter TxPDO 33 | UINT8 | RO | 0x06 (6dec) |
1820:06 | Exclude TxPDOs | Specifies the TxPDOs (index of TxPDO mapping objects) that must not be transferred together with TxPDO 33 | OCTET-STRING[2] | RO | 21 1A |
Index 1821 DMC TxPDO-Par Inputs 32 Bit Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1821:0 | DMC TxPDO-Par Inputs 32 Bit Ch.1 | PDO parameter TxPDO 34 | UINT8 | RO | 0x06 (6dec) |
1821:06 | Exclude TxPDOs | Specifies the TxPDOs (index of TxPDO mapping objects) that must not be transferred together with TxPDO 34 | OCTET-STRING[2] | RO | 20 1A |
Index 1860 DMC TxPDO-Par Inputs Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1860:0 | DMC TxPDO-Par Inputs Ch.2 | PDO parameter TxPDO 97 | UINT8 | RO | 0x06 (6dec) |
1860:06 | Exclude TxPDOs | Specifies the TxPDOs (index of TxPDO mapping objects) that must not be transferred together with TxPDO 97 | OCTET-STRING[2] | RO | 61 1A |
Index 1861 DMC TxPDO-Par Inputs 32 Bit Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1861:0 | DMC TxPDO-Par Inputs 32 Bit Ch.2 | PDO parameter TxPDO 98 | UINT8 | RO | 0x06 (6dec) |
1861:06 | Exclude TxPDOs | Specifies the TxPDOs (index of TxPDO mapping objects) that must not be transferred together with TxPDO 98 | OCTET-STRING[2] | RO | 60 1A |
Index 1A00 FB TxPDO-Map Position Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A00:0 | FB TxPDO-Map Position Ch.1 | PDO Mapping TxPDO 1 | UINT8 | RO | 0x01 (1dec) |
1A00:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6000 (FB Inputs Ch.1), entry 0x11 (Position)) | UINT32 | RO | 0x6000:11, 32 |
Index 1A02 FB TxPDO-Map Status Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A02:0 | FB TxPDO-Map Status Ch.1 | PDO Mapping TxPDO 3 | UINT8 | RO | 0x03 (3dec) |
1A02:01 | SubIndex 001 | 1. PDO Mapping entry (13 bits align) | UINT32 | RO | 0x0000:00, 13 |
1A02:02 | SubIndex 002 | 2. PDO Mapping entry (object 0x6000 (FB Inputs Ch.1), entry 0x0E (TxPDO State)) | UINT32 | RO | 0x6000:0E, 1 |
1A02:03 | SubIndex 003 | 3. PDO Mapping entry (object 0x6000 (FB Inputs Ch.1), entry 0x0F (Input cycle counter)) | UINT32 | RO | 0x6000:0F, 2 |
Index 1A03 FB TxPDO-Map Touch probe status Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A03:0 | FB TxPDO-Map Touch probe status Ch.1 | PDO Mapping TxPDO 4 | UINT8 | RO | 0x0A (10dec) |
1A03:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6001 (FB Touch probe inputs Ch.1), entry 0x01 (TP1 Enable)) | UINT32 | RO | 0x6001:01, 1 |
1A03:02 | SubIndex 002 | 2. PDO Mapping entry (object 0x6001 (FB Touch probe inputs Ch.1), entry 0x02 (TP1 Pos value stored)) | UINT32 | RO | 0x6001:02, 1 |
1A03:03 | SubIndex 003 | 3. PDO Mapping entry (object 0x6001 (FB Touch probe inputs Ch.1), entry 0x03 (TP1 Neg value stored)) | UINT32 | RO | 0x6001:03, 1 |
1A03:04 | SubIndex 004 | 4. PDO Mapping entry (4 bits align) | UINT32 | RO | 0x0000:00, 4 |
1A03:05 | SubIndex 005 | 5. PDO Mapping entry (object 0x6001 (FB Touch probe inputs Ch.1), entry 0x08 (TP1 Input)) | UINT32 | RO | 0x6001:08, 1 |
1A03:06 | SubIndex 006 | 6. PDO Mapping entry (object 0x6001 (FB Touch probe inputs Ch.1), entry 0x09 (TP2 Enable)) | UINT32 | RO | 0x6001:09, 1 |
1A03:07 | SubIndex 007 | 7. PDO Mapping entry (object 0x6001 (FB Touch probe inputs Ch.1), entry 0x0A (TP2 Pos value stored)) | UINT32 | RO | 0x6001:0A, 1 |
1A03:08 | SubIndex 008 | 8. PDO Mapping entry (object 0x6001 (FB Touch probe inputs Ch.1), entry 0x0B (TP2 Neg value stored)) | UINT32 | RO | 0x6001:0B, 1 |
1A03:09 | SubIndex 009 | 9. PDO Mapping entry (4 bits align) | UINT32 | RO | 0x0000:00, 4 |
1A03:0A | SubIndex 010 | 10. PDO Mapping entry (object 0x6001 (FB Touch probe inputs Ch.1), entry 0x10 (TP2 Input)) | UINT32 | RO | 0x6001:10, 1 |
Index 1A04 FB TxPDO-Map Touch probe 1 pos position Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A04:0 | FB TxPDO-Map Touch probe 1 pos position Ch.1 | PDO Mapping TxPDO 5 | UINT8 | RO | 0x01 (1dec) |
1A04:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6001 (FB Touch probe inputs Ch.1), entry 0x11 (TP1 Pos position)) | UINT32 | RO | 0x6001:11, 32 |
Index 1A05 FB TxPDO-Map Touch probe 1 neg position Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A05:0 | FB TxPDO-Map Touch probe 1 neg position Ch.1 | PDO Mapping TxPDO 6 | UINT8 | RO | 0x01 (1dec) |
1A05:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6001 (FB Touch probe inputs Ch.1), entry 0x12 (TP1 Neg position)) | UINT32 | RO | 0x6001:12, 32 |
Index 1A06 FB TxPDO-Map Touch probe 2 pos position Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A06:0 | FB TxPDO-Map Touch probe 2 pos position Ch.1 | PDO Mapping TxPDO 7 | UINT8 | RO | 0x01 (1dec) |
1A06:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6001 (FB Touch probe inputs Ch.1), entry 0x13 (TP2 Pos position)) | UINT32 | RO | 0x6001:13, 32 |
Index 1A07 FB TxPDO-Map Touch probe 2 neg position Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A07:0 | FB TxPDO-Map Touch probe 2 neg position Ch.1 | PDO Mapping TxPDO 8 | UINT8 | RO | 0x01 (1dec) |
1A07:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6001 (FB Touch probe inputs Ch.1), entry 0x14 (TP2 Neg position)) | UINT32 | RO | 0x6001:14, 32 |
Index 1A08 FB TxPDO-Map Touch probe 1 pos timestamp Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A08:0 | FB TxPDO-Map Touch probe 1 pos timestamp Ch.1 | PDO Mapping TxPDO 9 | UINT8 | RO | 0x01 (1dec) |
1A08:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6001 (FB Touch probe inputs Ch.1), entry 0x15 (TP1 Pos timestamp)) | UINT32 | RO | 0x6001:15, 32 |
Index 1A09 FB TxPDO-Map Touch probe 1 neg timestamp Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A09:0 | FB TxPDO-Map Touch probe 1 neg timestamp Ch.1 | PDO Mapping TxPDO 10 | UINT8 | RO | 0x01 (1dec) |
1A09:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6001 (FB Touch probe inputs Ch.1), entry 0x16 (TP1 Neg timestamp)) | UINT32 | RO | 0x6001:16, 32 |
Index 1A0A FB TxPDO-Map Touch probe 2 pos timestamp Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A0A:0 | FB TxPDO-Map Touch probe 2 pos timestamp Ch.1 | PDO Mapping TxPDO 11 | UINT8 | RO | 0x01 (1dec) |
1A0A:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6001 (FB Touch probe inputs Ch.1), entry 0x17 (TP2 Pos timestamp)) | UINT32 | RO | 0x6001:17, 32 |
Index 1A0B FB TxPDO-Map Touch probe 2 neg timestamp Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A0B:0 | FB TxPDO-Map Touch probe 2 neg timestamp Ch.1 | PDO Mapping TxPDO 12 | UINT8 | RO | 0x01 (1dec) |
1A0B:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6001 (FB Touch probe inputs Ch.1), entry 0x18 (TP2 Neg timestamp)) | UINT32 | RO | 0x6001:18, 32 |
Index 1A10 DRV TxPDO-Map Statusword Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A10:0 | DRV TxPDO-Map Statusword Ch.1 | PDO Mapping TxPDO 17 | UINT8 | RO | 0x01 (1dec) |
1A10:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6010 (DRV Inputs Ch.1), entry 0x01 (Statusword)) | UINT32 | RO | 0x6010:01, 16 |
Index 1A11 DRV TxPDO-Map Following error actual value Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A11:0 | DRV TxPDO-Map Following error actual value Ch.1 | PDO Mapping TxPDO 18 | UINT8 | RO | 0x01 (1dec) |
1A11:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6010 (DRV Inputs Ch.1), entry 0x06 (Following error actual value)) | UINT32 | RO | 0x6010:06, 32 |
Index 1A12 DRV TxPDO-Map Velocity actual value Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A12:0 | DRV TxPDO-Map Velocity actual value Ch.1 | PDO Mapping TxPDO 19 | UINT8 | RO | 0x01 (1dec) |
1A12:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6010 (DRV Inputs Ch.1), entry 0x07 (Velocity actual value)) | UINT32 | RO | 0x6010:07, 32 |
Index 1A13 DRV TxPDO-Map Torque actual value Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A13:0 | DRV TxPDO-Map Torque actual value Ch.1 | PDO Mapping TxPDO 20 | UINT8 | RO | 0x01 (1dec) |
1A13:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6010 (DRV Inputs Ch.1), entry 0x08 (Torque actual value)) | UINT32 | RO | 0x6010:08, 16 |
Index 1A14 DRV TxPDO-Map Info data 1 Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A14:0 | DRV TxPDO-Map Info data 1 Ch.1 | PDO Mapping TxPDO 21 | UINT8 | RW | 0x01 (1dec) |
1A14:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6010 (DRV Inputs Ch.1), entry 0x12 (Info data 1)) | UINT32 | RW | 0x6010:12, 16 |
1A14:02 | SubIndex 002 | 2. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A14:03 | SubIndex 003 | 3. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A14:04 | SubIndex 004 | 4. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A14:05 | SubIndex 005 | 5. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A14:06 | SubIndex 006 | 6. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A14:07 | SubIndex 007 | 7. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A14:08 | SubIndex 008 | 8. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A14:09 | SubIndex 009 | 9. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A14:0A | SubIndex 010 | 10. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A14:0B | SubIndex 011 | 11. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A14:0C | SubIndex 012 | 12. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A14:0D | SubIndex 013 | 13. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A14:0E | SubIndex 014 | 14. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A14:0F | SubIndex 015 | 15. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A14:10 | SubIndex 016 | 16. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
Index 1A15 DRV TxPDO-Map Info data 2 Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A15:0 | DRV TxPDO-Map Info data 2 Ch.1 | PDO Mapping TxPDO 22 | UINT8 | RW | 0x01 (1dec) |
1A15:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6010 (DRV Inputs Ch.1), entry 0x13 (Info data 2)) | UINT32 | RW | 0x6010:13, 16 |
1A15:02 | SubIndex 002 | 2. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A15:03 | SubIndex 003 | 3. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A15:04 | SubIndex 004 | 4. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A15:05 | SubIndex 005 | 5. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A15:06 | SubIndex 006 | 6. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A15:07 | SubIndex 007 | 7. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A15:08 | SubIndex 008 | 8. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A15:09 | SubIndex 009 | 9. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A15:0A | SubIndex 010 | 10. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A15:0B | SubIndex 011 | 11. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A15:0C | SubIndex 012 | 12. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A15:0D | SubIndex 013 | 13. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A15:0E | SubIndex 014 | 14. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A15:0F | SubIndex 015 | 15. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A15:10 | SubIndex 016 | 16. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
Index 1A16 DRV TxPDO-Map Info data 3 Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A16:0 | DRV TxPDO-Map Info data 3 Ch.1 | PDO Mapping TxPDO 23 | UINT8 | RW | 0x01 (1dec) |
1A16:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6010 (DRV Inputs Ch.1), entry 0x14 (Info data 3)) | UINT32 | RW | 0x6010:14, 16 |
1A16:02 | SubIndex 002 | 2. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A16:03 | SubIndex 003 | 3. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A16:04 | SubIndex 004 | 4. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A16:05 | SubIndex 005 | 5. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A16:06 | SubIndex 006 | 6. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A16:07 | SubIndex 007 | 7. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A16:08 | SubIndex 008 | 8. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A16:09 | SubIndex 009 | 9. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A16:0A | SubIndex 010 | 10. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A16:0B | SubIndex 011 | 11. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A16:0C | SubIndex 012 | 12. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A16:0D | SubIndex 013 | 13. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A16:0E | SubIndex 014 | 14. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A16:0F | SubIndex 015 | 15. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A16:10 | SubIndex 016 | 16. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
Index 1A17 DRV TxPDO-Map Modes of operation display Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A17:0 | DRV TxPDO-Map Modes of operation display Ch.1 | PDO Mapping TxPDO 24 | UINT8 | RO | 0x01 (1dec) |
1A17:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6010 (DRV Inputs Ch.1), entry 0x03 (Modes of operation display)) | UINT32 | RO | 0x6010:03, 8 |
Index 1A18 DRV TxPDO-Map Torque limitation status Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A18:0 | DRV TxPDO-Map Torque limitation status Ch.1 | PDO Mapping TxPDO 25 | UINT8 | RO | 0x01 (1dec) |
1A18:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6010 (DRV Inputs Ch.1), entry 0x15 (Torque limitation status)) | UINT32 | RO | 0x6010:15, 8 |
Index 1A20 DMC TxPDO-Map Inputs Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A20:0 | DMC TxPDO-Map Inputs Ch.1 | PDO Mapping TxPDO 33 | UINT8 | RO | 0x26 (38dec) |
1A20:01 | SubIndex 001 | 1. PDO Mapping entry (1 bits align) | UINT32 | RO | 0x0000:00, 1 |
1A20:02 | SubIndex 002 | 2. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x02 (DMC__FeedbackStatus__Latch extern valid)) | UINT32 | RO | 0x6020:02, 1 |
1A20:03 | SubIndex 003 | 3. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x03 (DMC__FeedbackStatus__Set counter done)) | UINT32 | RO | 0x6020:03, 1 |
1A20:04 | SubIndex 004 | 4. PDO Mapping entry (9 bits align) | UINT32 | RO | 0x0000:00, 9 |
1A20:05 | SubIndex 005 | 5. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x0D (DMC__FeedbackStatus__Status of extern latch)) | UINT32 | RO | 0x6020:0D, 1 |
1A20:06 | SubIndex 006 | 6. PDO Mapping entry (3 bits align) | UINT32 | RO | 0x0000:00, 3 |
1A20:07 | SubIndex 007 | 7. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x11 (DMC__DriveStatus__Ready to enable)) | UINT32 | RO | 0x6020:11, 1 |
1A20:08 | SubIndex 008 | 8. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x12 (DMC__DriveStatus__Ready)) | UINT32 | RO | 0x6020:12, 1 |
1A20:09 | SubIndex 009 | 9. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x13 (DMC__DriveStatus__Warning)) | UINT32 | RO | 0x6020:13, 1 |
1A20:0A | SubIndex 010 | 10. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x14 (DMC__DriveStatus__Error)) | UINT32 | RO | 0x6020:14, 1 |
1A20:0B | SubIndex 011 | 11. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x15 (DMC__DriveStatus__Moving positive)) | UINT32 | RO | 0x6020:15, 1 |
1A20:0C | SubIndex 012 | 12. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x16 (DMC__DriveStatus__Moving negative)) | UINT32 | RO | 0x6020:16, 1 |
1A20:0D | SubIndex 013 | 13. PDO Mapping entry (5 bits align) | UINT32 | RO | 0x0000:00, 5 |
1A20:0E | SubIndex 014 | 14. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x1C (DMC__DriveStatus__Digital input 1)) | UINT32 | RO | 0x6020:1C, 1 |
1A20:0F | SubIndex 015 | 15. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x1D (DMC__DriveStatus__Digital input 2)) | UINT32 | RO | 0x6020:1D, 1 |
1A20:10 | SubIndex 016 | 16. PDO Mapping entry (3 bits align) | UINT32 | RO | 0x0000:00, 3 |
1A20:11 | SubIndex 017 | 17. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x21 (DMC__PositioningStatus__Busy)) | UINT32 | RO | 0x6020:21, 1 |
1A20:12 | SubIndex 018 | 18. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x22 (DMC__PositioningStatus__In-Target)) | UINT32 | RO | 0x6020:22, 1 |
1A20:13 | SubIndex 019 | 19. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x23 (DMC__PositioningStatus__Warning)) | UINT32 | RO | 0x6020:23, 1 |
1A20:14 | SubIndex 020 | 20. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x24 (DMC__PositioningStatus__Error)) | UINT32 | RO | 0x6020:24, 1 |
1A20:15 | SubIndex 021 | 21. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x25 (DMC__PositioningStatus__Calibrated)) | UINT32 | RO | 0x6020:25, 1 |
1A20:16 | SubIndex 022 | 22. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x26 (DMC__PositioningStatus__Accelerate)) | UINT32 | RO | 0x6020:26, 1 |
1A20:17 | SubIndex 023 | 23. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x27 (DMC__PositioningStatus__Decelerate)) | UINT32 | RO | 0x6020:27, 1 |
1A20:18 | SubIndex 024 | 24. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x28 (DMC__PositioningStatus__Ready to execute)) | UINT32 | RO | 0x6020:28, 1 |
1A20:19 | SubIndex 025 | 25. PDO Mapping entry (8 bits align) | UINT32 | RO | 0x0000:00, 8 |
1A20:1A | SubIndex 026 | 26. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x31 (DMC__Set position)) | UINT32 | RO | 0x6020:31, 64 |
1A20:1B | SubIndex 027 | 27. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x32 (DMC__Set velocity)) | UINT32 | RO | 0x6020:32, 16 |
1A20:1C | SubIndex 028 | 28. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x33 (DMC__Actual drive time)) | UINT32 | RO | 0x6020:33, 32 |
1A20:1D | SubIndex 029 | 29. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x34 (DMC__Actual position lag)) | UINT32 | RO | 0x6020:34, 64 |
1A20:1E | SubIndex 030 | 30. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x35 (DMC__Actual velocity)) | UINT32 | RO | 0x6020:35, 16 |
1A20:1F | SubIndex 031 | 31. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x36 (DMC__Actual position)) | UINT32 | RO | 0x6020:36, 64 |
1A20:20 | SubIndex 032 | 32. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x37 (DMC__Error id)) | UINT32 | RO | 0x6020:37, 32 |
1A20:21 | SubIndex 033 | 33. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x38 (DMC__Input cycle counter)) | UINT32 | RO | 0x6020:38, 8 |
1A20:22 | SubIndex 034 | 34. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x39 (DMC__Channel id)) | UINT32 | RO | 0x6020:39, 8 |
1A20:23 | SubIndex 035 | 35. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x3A (DMC__Latch value)) | UINT32 | RO | 0x6020:3A, 64 |
1A20:24 | SubIndex 036 | 36. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x3B (DMC__Cyclic info data 1)) | UINT32 | RO | 0x6020:3B, 16 |
1A20:25 | SubIndex 037 | 37. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x3C (DMC__Cyclic info data 2)) | UINT32 | RO | 0x6020:3C, 16 |
1A20:26 | SubIndex 038 | 38. PDO Mapping entry (64 bits align) | UINT32 | RO | 0x0000:00, 64 |
Index 1A21 DMC TxPDO-Map Inputs 32 Bit Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A21:0 | DMC TxPDO-Map Inputs 32 Bit Ch.1 | PDO Mapping TxPDO 34 | UINT8 | RO | 0x2A (42dec) |
1A21:01 | SubIndex 001 | 1. PDO Mapping entry (1 bits align) | UINT32 | RO | 0x0000:00, 1 |
1A21:02 | SubIndex 002 | 2. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x02 (DMC__FeedbackStatus__Latch extern valid)) | UINT32 | RO | 0x6020:02, 1 |
1A21:03 | SubIndex 003 | 3. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x03 (DMC__FeedbackStatus__Set counter done)) | UINT32 | RO | 0x6020:03, 1 |
1A21:04 | SubIndex 004 | 4. PDO Mapping entry (9 bits align) | UINT32 | RO | 0x0000:00, 9 |
1A21:05 | SubIndex 005 | 5. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x0D (DMC__FeedbackStatus__Status of extern latch)) | UINT32 | RO | 0x6020:0D, 1 |
1A21:06 | SubIndex 006 | 6. PDO Mapping entry (3 bits align) | UINT32 | RO | 0x0000:00, 3 |
1A21:07 | SubIndex 007 | 7. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x11 (DMC__DriveStatus__Ready to enable)) | UINT32 | RO | 0x6020:11, 1 |
1A21:08 | SubIndex 008 | 8. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x12 (DMC__DriveStatus__Ready)) | UINT32 | RO | 0x6020:12, 1 |
1A21:09 | SubIndex 009 | 9. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x13 (DMC__DriveStatus__Warning)) | UINT32 | RO | 0x6020:13, 1 |
1A21:0A | SubIndex 010 | 10. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x14 (DMC__DriveStatus__Error)) | UINT32 | RO | 0x6020:14, 1 |
1A21:0B | SubIndex 011 | 11. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x15 (DMC__DriveStatus__Moving positive)) | UINT32 | RO | 0x6020:15, 1 |
1A21:0C | SubIndex 012 | 12. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x16 (DMC__DriveStatus__Moving negative)) | UINT32 | RO | 0x6020:16, 1 |
1A21:0D | SubIndex 013 | 13. PDO Mapping entry (5 bits align) | UINT32 | RO | 0x0000:00, 5 |
1A21:0E | SubIndex 014 | 14. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x1C (DMC__DriveStatus__Digital input 1)) | UINT32 | RO | 0x6020:1C, 1 |
1A21:0F | SubIndex 015 | 15. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x1D (DMC__DriveStatus__Digital input 2)) | UINT32 | RO | 0x6020:1D, 1 |
1A21:10 | SubIndex 016 | 16. PDO Mapping entry (3 bits align) | UINT32 | RO | 0x0000:00, 3 |
1A21:11 | SubIndex 017 | 17. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x21 (DMC__PositioningStatus__Busy)) | UINT32 | RO | 0x6020:21, 1 |
1A21:12 | SubIndex 018 | 18. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x22 (DMC__PositioningStatus__In-Target)) | UINT32 | RO | 0x6020:22, 1 |
1A21:13 | SubIndex 019 | 19. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x23 (DMC__PositioningStatus__Warning)) | UINT32 | RO | 0x6020:23, 1 |
1A21:14 | SubIndex 020 | 20. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x24 (DMC__PositioningStatus__Error)) | UINT32 | RO | 0x6020:24, 1 |
1A21:15 | SubIndex 021 | 21. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x25 (DMC__PositioningStatus__Calibrated)) | UINT32 | RO | 0x6020:25, 1 |
1A21:16 | SubIndex 022 | 22. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x26 (DMC__PositioningStatus__Accelerate)) | UINT32 | RO | 0x6020:26, 1 |
1A21:17 | SubIndex 023 | 23. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x27 (DMC__PositioningStatus__Decelerate)) | UINT32 | RO | 0x6020:27, 1 |
1A21:18 | SubIndex 024 | 24. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x28 (DMC__PositioningStatus__Ready to execute)) | UINT32 | RO | 0x6020:28, 1 |
1A21:19 | SubIndex 025 | 25. PDO Mapping entry (8 bits align) | UINT32 | RO | 0x0000:00, 8 |
1A21:1A | SubIndex 026 | 26. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x31 (DMC__Set position)) | UINT32 | RO | 0x6020:31, 32 |
1A21:1B | SubIndex 027 | 27. PDO Mapping entry (32 bits align) | UINT32 | RO | 0x0000:00, 32 |
1A21:1C | SubIndex 028 | 28. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x32 (DMC__Set velocity)) | UINT32 | RO | 0x6020:32, 16 |
1A21:1D | SubIndex 029 | 29. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x33 (DMC__Actual drive time)) | UINT32 | RO | 0x6020:33, 32 |
1A21:1E | SubIndex 030 | 30. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x34 (DMC__Actual position lag)) | UINT32 | RO | 0x6020:34, 32 |
1A21:1F | SubIndex 031 | 31. PDO Mapping entry (32 bits align) | UINT32 | RO | 0x0000:00, 32 |
1A21:20 | SubIndex 032 | 32. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x35 (DMC__Actual velocity)) | UINT32 | RO | 0x6020:35, 16 |
1A21:21 | SubIndex 033 | 33. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x36 (DMC__Actual position)) | UINT32 | RO | 0x6020:36, 32 |
1A21:22 | SubIndex 034 | 34. PDO Mapping entry (32 bits align) | UINT32 | RO | 0x0000:00, 32 |
1A21:23 | SubIndex 035 | 35. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x37 (DMC__Error id)) | UINT32 | RO | 0x6020:37, 32 |
1A21:24 | SubIndex 036 | 36. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x38 (DMC__Input cycle counter)) | UINT32 | RO | 0x6020:38, 8 |
1A21:25 | SubIndex 037 | 37. PDO Mapping entry (8 bits align) | UINT32 | RO | 0x0000:00, 8 |
1A21:26 | SubIndex 038 | 38. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x3A (DMC__Latch value)) | UINT32 | RO | 0x6020:3A, 32 |
1A21:27 | SubIndex 039 | 39. PDO Mapping entry (32 bits align) | UINT32 | RO | 0x0000:00, 32 |
1A21:28 | SubIndex 040 | 40. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x3B (DMC__Cyclic info data 1)) | UINT32 | RO | 0x6020:3B, 16 |
1A21:29 | SubIndex 041 | 41. PDO Mapping entry (object 0x6020 (DMC Inputs Ch.1), entry 0x3C (DMC__Cyclic info data 2)) | UINT32 | RO | 0x6020:3C, 16 |
1A21:2A | SubIndex 042 | 42. PDO Mapping entry (64 bits align) | UINT32 | RO | 0x0000:00, 64 |
Index 1A40 FB TxPDO-Map Position Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A40:0 | FB TxPDO-Map Position Ch.2 | PDO Mapping TxPDO 65 | UINT8 | RO | 0x01 (1dec) |
1A40:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6100 (FB Inputs Ch.2), entry 0x11 (Position)) | UINT32 | RO | 0x6100:11, 32 |
Index 1A42 FB TxPDO-Map Status Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A42:0 | FB TxPDO-Map Status Ch.2 | PDO Mapping TxPDO 67 | UINT8 | RO | 0x03 (3dec) |
1A42:01 | SubIndex 001 | 1. PDO Mapping entry (13 bits align) | UINT32 | RO | 0x0000:00, 13 |
1A42:02 | SubIndex 002 | 2. PDO Mapping entry (object 0x6100 (FB Inputs Ch.2), entry 0x0E (TxPDO State)) | UINT32 | RO | 0x6100:0E, 1 |
1A42:03 | SubIndex 003 | 3. PDO Mapping entry (object 0x6100 (FB Inputs Ch.2), entry 0x0F (Input cycle counter)) | UINT32 | RO | 0x6100:0F, 2 |
Index 1A43 FB TxPDO-Map Touch probe status Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A43:0 | FB TxPDO-Map Touch probe status Ch.2 | PDO Mapping TxPDO 68 | UINT8 | RO | 0x0A (10dec) |
1A43:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6101 (FB Touch probe inputs Ch.2), entry 0x01 (TP1 Enable)) | UINT32 | RO | 0x6101:01, 1 |
1A43:02 | SubIndex 002 | 2. PDO Mapping entry (object 0x6101 (FB Touch probe inputs Ch.2), entry 0x02 (TP1 Pos value stored)) | UINT32 | RO | 0x6101:02, 1 |
1A43:03 | SubIndex 003 | 3. PDO Mapping entry (object 0x6101 (FB Touch probe inputs Ch.2), entry 0x03 (TP1 Neg value stored)) | UINT32 | RO | 0x6101:03, 1 |
1A43:04 | SubIndex 004 | 4. PDO Mapping entry (4 bits align) | UINT32 | RO | 0x0000:00, 4 |
1A43:05 | SubIndex 005 | 5. PDO Mapping entry (object 0x6101 (FB Touch probe inputs Ch.2), entry 0x08 (TP1 Input)) | UINT32 | RO | 0x6101:08, 1 |
1A43:06 | SubIndex 006 | 6. PDO Mapping entry (object 0x6101 (FB Touch probe inputs Ch.2), entry 0x09 (TP2 Enable)) | UINT32 | RO | 0x6101:09, 1 |
1A43:07 | SubIndex 007 | 7. PDO Mapping entry (object 0x6101 (FB Touch probe inputs Ch.2), entry 0x0A (TP2 Pos value stored)) | UINT32 | RO | 0x6101:0A, 1 |
1A43:08 | SubIndex 008 | 8. PDO Mapping entry (object 0x6101 (FB Touch probe inputs Ch.2), entry 0x0B (TP2 Neg value stored)) | UINT32 | RO | 0x6101:0B, 1 |
1A43:09 | SubIndex 009 | 9. PDO Mapping entry (4 bits align) | UINT32 | RO | 0x0000:00, 4 |
1A43:0A | SubIndex 010 | 10. PDO Mapping entry (object 0x6101 (FB Touch probe inputs Ch.2), entry 0x10 (TP2 Input)) | UINT32 | RO | 0x6101:10, 1 |
Index 1A44 FB TxPDO-Map Touch probe 1 pos position Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A44:0 | FB TxPDO-Map Touch probe 1 pos position Ch.2 | PDO Mapping TxPDO 69 | UINT8 | RO | 0x01 (1dec) |
1A44:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6101 (FB Touch probe inputs Ch.2), entry 0x11 (TP1 Pos position)) | UINT32 | RO | 0x6101:11, 32 |
Index 1A45 FB TxPDO-Map Touch probe 1 neg position Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A45:0 | FB TxPDO-Map Touch probe 1 neg position Ch.2 | PDO Mapping TxPDO 70 | UINT8 | RO | 0x01 (1dec) |
1A45:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6101 (FB Touch probe inputs Ch.2), entry 0x12 (TP1 Neg position)) | UINT32 | RO | 0x6101:12, 32 |
Index 1A46 FB TxPDO-Map Touch probe 2 pos position Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A46:0 | FB TxPDO-Map Touch probe 2 pos position Ch.2 | PDO Mapping TxPDO 71 | UINT8 | RO | 0x01 (1dec) |
1A46:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6101 (FB Touch probe inputs Ch.2), entry 0x13 (TP2 Pos position)) | UINT32 | RO | 0x6101:13, 32 |
Index 1A47 FB TxPDO-Map Touch probe 2 neg position Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A47:0 | FB TxPDO-Map Touch probe 2 neg position Ch.2 | PDO Mapping TxPDO 72 | UINT8 | RO | 0x01 (1dec) |
1A47:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6101 (FB Touch probe inputs Ch.2), entry 0x14 (TP2 Neg position)) | UINT32 | RO | 0x6101:14, 32 |
Index 1A48 FB TxPDO-Map Touch probe 1 pos timestamp Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A48:0 | FB TxPDO-Map Touch probe 1 pos timestamp Ch.2 | PDO Mapping TxPDO 73 | UINT8 | RO | 0x01 (1dec) |
1A48:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6101 (FB Touch probe inputs Ch.2), entry 0x15 (TP1 Pos timestamp)) | UINT32 | RO | 0x6101:15, 32 |
Index 1A49 FB TxPDO-Map Touch probe 1 neg timestamp Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A49:0 | FB TxPDO-Map Touch probe 1 neg timestamp Ch.2 | PDO Mapping TxPDO 74 | UINT8 | RO | 0x01 (1dec) |
1A49:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6101 (FB Touch probe inputs Ch.2), entry 0x16 (TP1 Neg timestamp)) | UINT32 | RO | 0x6101:16, 32 |
Index 1A4A FB TxPDO-Map Touch probe 2 pos timestamp Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A4A:0 | FB TxPDO-Map Touch probe 2 pos timestamp Ch.2 | PDO Mapping TxPDO 75 | UINT8 | RO | 0x01 (1dec) |
1A4A:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6101 (FB Touch probe inputs Ch.2), entry 0x17 (TP2 Pos timestamp)) | UINT32 | RO | 0x6101:17, 32 |
Index 1A4B FB TxPDO-Map Touch probe 2 neg timestamp Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A4B:0 | FB TxPDO-Map Touch probe 2 neg timestamp Ch.2 | PDO Mapping TxPDO 76 | UINT8 | RO | 0x01 (1dec) |
1A4B:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6101 (FB Touch probe inputs Ch.2), entry 0x18 (TP2 Neg timestamp)) | UINT32 | RO | 0x6101:18, 32 |
Index 1A50 DRV TxPDO-Map Statusword Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A50:0 | DRV TxPDO-Map Statusword Ch.2 | PDO Mapping TxPDO 81 | UINT8 | RO | 0x01 (1dec) |
1A50:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6110 (DRV Inputs Ch.2), entry 0x01 (Statusword)) | UINT32 | RO | 0x6110:01, 16 |
Index 1A51 DRV TxPDO-Map Following error actual value Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A51:0 | DRV TxPDO-Map Following error actual value Ch.2 | PDO Mapping TxPDO 82 | UINT8 | RO | 0x01 (1dec) |
1A51:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6110 (DRV Inputs Ch.2), entry 0x06 (Following error actual value)) | UINT32 | RO | 0x6110:06, 32 |
Index 1A52 DRV TxPDO-Map Velocity actual value Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A52:0 | DRV TxPDO-Map Velocity actual value Ch.2 | PDO Mapping TxPDO 83 | UINT8 | RO | 0x01 (1dec) |
1A52:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6110 (DRV Inputs Ch.2), entry 0x07 (Velocity actual value)) | UINT32 | RO | 0x6110:07, 32 |
Index 1A53 DRV TxPDO-Map Torque actual value Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A53:0 | DRV TxPDO-Map Torque actual value Ch.2 | PDO Mapping TxPDO 84 | UINT8 | RO | 0x01 (1dec) |
1A53:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6110 (DRV Inputs Ch.2), entry 0x08 (Torque actual value)) | UINT32 | RO | 0x6110:08, 16 |
Index 1A54 DRV TxPDO-Map Info data 1 Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A54:0 | DRV TxPDO-Map Info data 1 Ch.2 | PDO Mapping TxPDO 85 | UINT8 | RW | 0x01 (1dec) |
1A54:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6110 (DRV Inputs Ch.2), entry 0x12 (Info data 1)) | UINT32 | RW | 0x6110:12, 16 |
1A54:02 | SubIndex 002 | 2. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A54:03 | SubIndex 003 | 3. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A54:04 | SubIndex 004 | 4. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A54:05 | SubIndex 005 | 5. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A54:06 | SubIndex 006 | 6. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A54:07 | SubIndex 007 | 7. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A54:08 | SubIndex 008 | 8. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A54:09 | SubIndex 009 | 9. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A54:0A | SubIndex 010 | 10. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A54:0B | SubIndex 011 | 11. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A54:0C | SubIndex 012 | 12. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A54:0D | SubIndex 013 | 13. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A54:0E | SubIndex 014 | 14. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A54:0F | SubIndex 015 | 15. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A54:10 | SubIndex 016 | 16. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
Index 1A55 DRV TxPDO-Map Info data 2 Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A55:0 | DRV TxPDO-Map Info data 2 Ch.2 | PDO Mapping TxPDO 86 | UINT8 | RW | 0x01 (1dec) |
1A55:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6110 (DRV Inputs Ch.2), entry 0x13 (Info data 2)) | UINT32 | RW | 0x6110:13, 16 |
1A55:02 | SubIndex 002 | 2. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A55:03 | SubIndex 003 | 3. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A55:04 | SubIndex 004 | 4. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A55:05 | SubIndex 005 | 5. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A55:06 | SubIndex 006 | 6. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A55:07 | SubIndex 007 | 7. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A55:08 | SubIndex 008 | 8. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A55:09 | SubIndex 009 | 9. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A55:0A | SubIndex 010 | 10. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A55:0B | SubIndex 011 | 11. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A55:0C | SubIndex 012 | 12. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A55:0D | SubIndex 013 | 13. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A55:0E | SubIndex 014 | 14. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A55:0F | SubIndex 015 | 15. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A55:10 | SubIndex 016 | 16. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
Index 1A56 DRV TxPDO-Map Info data 3 Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A56:0 | DRV TxPDO-Map Info data 3 Ch.2 | PDO Mapping TxPDO 87 | UINT8 | RW | 0x01 (1dec) |
1A56:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6110 (DRV Inputs Ch.2), entry 0x14 (Info data 3)) | UINT32 | RW | 0x6110:14, 16 |
1A56:02 | SubIndex 002 | 2. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A56:03 | SubIndex 003 | 3. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A56:04 | SubIndex 004 | 4. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A56:05 | SubIndex 005 | 5. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A56:06 | SubIndex 006 | 6. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A56:07 | SubIndex 007 | 7. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A56:08 | SubIndex 008 | 8. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A56:09 | SubIndex 009 | 9. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A56:0A | SubIndex 010 | 10. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A56:0B | SubIndex 011 | 11. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A56:0C | SubIndex 012 | 12. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A56:0D | SubIndex 013 | 13. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A56:0E | SubIndex 014 | 14. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A56:0F | SubIndex 015 | 15. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
1A56:10 | SubIndex 016 | 16. PDO Mapping entry (0 bits align) | UINT32 | RW | 0x0000:00, 0 |
Index 1A57 DRV TxPDO-Map Modes of operation display Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A57:0 | DRV TxPDO-Map Modes of operation display Ch.2 | PDO Mapping TxPDO 88 | UINT8 | RO | 0x01 (1dec) |
1A57:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6110 (DRV Inputs Ch.2), entry 0x03 (Modes of operation display)) | UINT32 | RO | 0x6110:03, 8 |
Index 1A58 DRV TxPDO-Map Torque limitation status Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A58:0 | DRV TxPDO-Map Torque limitation status Ch.2 | PDO Mapping TxPDO 89 | UINT8 | RO | 0x01 (1dec) |
1A58:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6110 (DRV Inputs Ch.2), entry 0x15 (Torque limitation status)) | UINT32 | RO | 0x6110:15, 8 |
Index 1A60 DMC TxPDO-Map Inputs Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A60:0 | DMC TxPDO-Map Inputs Ch.2 | PDO Mapping TxPDO 97 | UINT8 | RO | 0x26 (38dec) |
1A60:01 | SubIndex 001 | 1. PDO Mapping entry (1 bits align) | UINT32 | RO | 0x0000:00, 1 |
1A60:02 | SubIndex 002 | 2. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x02 (DMC__FeedbackStatus__Latch extern valid)) | UINT32 | RO | 0x6120:02, 1 |
1A60:03 | SubIndex 003 | 3. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x03 (DMC__FeedbackStatus__Set counter done)) | UINT32 | RO | 0x6120:03, 1 |
1A60:04 | SubIndex 004 | 4. PDO Mapping entry (9 bits align) | UINT32 | RO | 0x0000:00, 9 |
1A60:05 | SubIndex 005 | 5. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x0D (DMC__FeedbackStatus__Status of extern latch)) | UINT32 | RO | 0x6120:0D, 1 |
1A60:06 | SubIndex 006 | 6. PDO Mapping entry (3 bits align) | UINT32 | RO | 0x0000:00, 3 |
1A60:07 | SubIndex 007 | 7. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x11 (DMC__DriveStatus__Ready to enable)) | UINT32 | RO | 0x6120:11, 1 |
1A60:08 | SubIndex 008 | 8. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x12 (DMC__DriveStatus__Ready)) | UINT32 | RO | 0x6120:12, 1 |
1A60:09 | SubIndex 009 | 9. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x13 (DMC__DriveStatus__Warning)) | UINT32 | RO | 0x6120:13, 1 |
1A60:0A | SubIndex 010 | 10. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x14 (DMC__DriveStatus__Error)) | UINT32 | RO | 0x6120:14, 1 |
1A60:0B | SubIndex 011 | 11. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x15 (DMC__DriveStatus__Moving positive)) | UINT32 | RO | 0x6120:15, 1 |
1A60:0C | SubIndex 012 | 12. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x16 (DMC__DriveStatus__Moving negative)) | UINT32 | RO | 0x6120:16, 1 |
1A60:0D | SubIndex 013 | 13. PDO Mapping entry (5 bits align) | UINT32 | RO | 0x0000:00, 5 |
1A60:0E | SubIndex 014 | 14. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x1C (DMC__DriveStatus__Digital input 1)) | UINT32 | RO | 0x6120:1C, 1 |
1A60:0F | SubIndex 015 | 15. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x1D (DMC__DriveStatus__Digital input 2)) | UINT32 | RO | 0x6120:1D, 1 |
1A60:10 | SubIndex 016 | 16. PDO Mapping entry (3 bits align) | UINT32 | RO | 0x0000:00, 3 |
1A60:11 | SubIndex 017 | 17. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x21 (DMC__PositioningStatus__Busy)) | UINT32 | RO | 0x6120:21, 1 |
1A60:12 | SubIndex 018 | 18. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x22 (DMC__PositioningStatus__In-Target)) | UINT32 | RO | 0x6120:22, 1 |
1A60:13 | SubIndex 019 | 19. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x23 (DMC__PositioningStatus__Warning)) | UINT32 | RO | 0x6120:23, 1 |
1A60:14 | SubIndex 020 | 20. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x24 (DMC__PositioningStatus__Error)) | UINT32 | RO | 0x6120:24, 1 |
1A60:15 | SubIndex 021 | 21. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x25 (DMC__PositioningStatus__Calibrated)) | UINT32 | RO | 0x6120:25, 1 |
1A60:16 | SubIndex 022 | 22. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x26 (DMC__PositioningStatus__Accelerate)) | UINT32 | RO | 0x6120:26, 1 |
1A60:17 | SubIndex 023 | 23. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x27 (DMC__PositioningStatus__Decelerate)) | UINT32 | RO | 0x6120:27, 1 |
1A60:18 | SubIndex 024 | 24. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x28 (DMC__PositioningStatus__Ready to execute)) | UINT32 | RO | 0x6120:28, 1 |
1A60:19 | SubIndex 025 | 25. PDO Mapping entry (8 bits align) | UINT32 | RO | 0x0000:00, 8 |
1A60:1A | SubIndex 026 | 26. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x31 (DMC__Set position)) | UINT32 | RO | 0x6120:31, 64 |
1A60:1B | SubIndex 027 | 27. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x32 (DMC__Set velocity)) | UINT32 | RO | 0x6120:32, 16 |
1A60:1C | SubIndex 028 | 28. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x33 (DMC__Actual drive time)) | UINT32 | RO | 0x6120:33, 32 |
1A60:1D | SubIndex 029 | 29. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x34 (DMC__Actual position lag)) | UINT32 | RO | 0x6120:34, 64 |
1A60:1E | SubIndex 030 | 30. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x35 (DMC__Actual velocity)) | UINT32 | RO | 0x6120:35, 16 |
1A60:1F | SubIndex 031 | 31. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x36 (DMC__Actual position)) | UINT32 | RO | 0x6120:36, 64 |
1A60:20 | SubIndex 032 | 32. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x37 (DMC__Error id)) | UINT32 | RO | 0x6120:37, 32 |
1A60:21 | SubIndex 033 | 33. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x38 (DMC__Input cycle counter)) | UINT32 | RO | 0x6120:38, 8 |
1A60:22 | SubIndex 034 | 34. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x39 (DMC__Channel id)) | UINT32 | RO | 0x6120:39, 8 |
1A60:23 | SubIndex 035 | 35. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x3A (DMC__Latch value)) | UINT32 | RO | 0x6120:3A, 64 |
1A60:24 | SubIndex 036 | 36. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x3B (DMC__Cyclic info data 1)) | UINT32 | RO | 0x6120:3B, 16 |
1A60:25 | SubIndex 037 | 37. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x3C (DMC__Cyclic info data 2)) | UINT32 | RO | 0x6120:3C, 16 |
1A60:26 | SubIndex 038 | 38. PDO Mapping entry (64 bits align) | UINT32 | RO | 0x0000:00, 64 |
Index 1A61 DMC TxPDO-Map Inputs 32 Bit Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A61:0 | DMC TxPDO-Map Inputs 32 Bit Ch.2 | PDO Mapping TxPDO 98 | UINT8 | RO | 0x2A (42dec) |
1A61:01 | SubIndex 001 | 1. PDO Mapping entry (1 bits align) | UINT32 | RO | 0x0000:00, 1 |
1A61:02 | SubIndex 002 | 2. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x02 (DMC__FeedbackStatus__Latch extern valid)) | UINT32 | RO | 0x6120:02, 1 |
1A61:03 | SubIndex 003 | 3. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x03 (DMC__FeedbackStatus__Set counter done)) | UINT32 | RO | 0x6120:03, 1 |
1A61:04 | SubIndex 004 | 4. PDO Mapping entry (9 bits align) | UINT32 | RO | 0x0000:00, 9 |
1A61:05 | SubIndex 005 | 5. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x0D (DMC__FeedbackStatus__Status of extern latch)) | UINT32 | RO | 0x6120:0D, 1 |
1A61:06 | SubIndex 006 | 6. PDO Mapping entry (3 bits align) | UINT32 | RO | 0x0000:00, 3 |
1A61:07 | SubIndex 007 | 7. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x11 (DMC__DriveStatus__Ready to enable)) | UINT32 | RO | 0x6120:11, 1 |
1A61:08 | SubIndex 008 | 8. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x12 (DMC__DriveStatus__Ready)) | UINT32 | RO | 0x6120:12, 1 |
1A61:09 | SubIndex 009 | 9. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x13 (DMC__DriveStatus__Warning)) | UINT32 | RO | 0x6120:13, 1 |
1A61:0A | SubIndex 010 | 10. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x14 (DMC__DriveStatus__Error)) | UINT32 | RO | 0x6120:14, 1 |
1A61:0B | SubIndex 011 | 11. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x15 (DMC__DriveStatus__Moving positive)) | UINT32 | RO | 0x6120:15, 1 |
1A61:0C | SubIndex 012 | 12. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x16 (DMC__DriveStatus__Moving negative)) | UINT32 | RO | 0x6120:16, 1 |
1A61:0D | SubIndex 013 | 13. PDO Mapping entry (5 bits align) | UINT32 | RO | 0x0000:00, 5 |
1A61:0E | SubIndex 014 | 14. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x1C (DMC__DriveStatus__Digital input 1)) | UINT32 | RO | 0x6120:1C, 1 |
1A61:0F | SubIndex 015 | 15. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x1D (DMC__DriveStatus__Digital input 2)) | UINT32 | RO | 0x6120:1D, 1 |
1A61:10 | SubIndex 016 | 16. PDO Mapping entry (3 bits align) | UINT32 | RO | 0x0000:00, 3 |
1A61:11 | SubIndex 017 | 17. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x21 (DMC__PositioningStatus__Busy)) | UINT32 | RO | 0x6120:21, 1 |
1A61:12 | SubIndex 018 | 18. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x22 (DMC__PositioningStatus__In-Target)) | UINT32 | RO | 0x6120:22, 1 |
1A61:13 | SubIndex 019 | 19. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x23 (DMC__PositioningStatus__Warning)) | UINT32 | RO | 0x6120:23, 1 |
1A61:14 | SubIndex 020 | 20. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x24 (DMC__PositioningStatus__Error)) | UINT32 | RO | 0x6120:24, 1 |
1A61:15 | SubIndex 021 | 21. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x25 (DMC__PositioningStatus__Calibrated)) | UINT32 | RO | 0x6120:25, 1 |
1A61:16 | SubIndex 022 | 22. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x26 (DMC__PositioningStatus__Accelerate)) | UINT32 | RO | 0x6120:26, 1 |
1A61:17 | SubIndex 023 | 23. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x27 (DMC__PositioningStatus__Decelerate)) | UINT32 | RO | 0x6120:27, 1 |
1A61:18 | SubIndex 024 | 24. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x28 (DMC__PositioningStatus__Ready to execute)) | UINT32 | RO | 0x6120:28, 1 |
1A61:19 | SubIndex 025 | 25. PDO Mapping entry (8 bits align) | UINT32 | RO | 0x0000:00, 8 |
1A61:1A | SubIndex 026 | 26. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x31 (DMC__Set position)) | UINT32 | RO | 0x6120:31, 32 |
1A61:1B | SubIndex 027 | 27. PDO Mapping entry (32 bits align) | UINT32 | RO | 0x0000:00, 32 |
1A61:1C | SubIndex 028 | 28. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x32 (DMC__Set velocity)) | UINT32 | RO | 0x6120:32, 16 |
1A61:1D | SubIndex 029 | 29. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x33 (DMC__Actual drive time)) | UINT32 | RO | 0x6120:33, 32 |
1A61:1E | SubIndex 030 | 30. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x34 (DMC__Actual position lag)) | UINT32 | RO | 0x6120:34, 32 |
1A61:1F | SubIndex 031 | 31. PDO Mapping entry (32 bits align) | UINT32 | RO | 0x0000:00, 32 |
1A61:20 | SubIndex 032 | 32. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x35 (DMC__Actual velocity)) | UINT32 | RO | 0x6120:35, 16 |
1A61:21 | SubIndex 033 | 33. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x36 (DMC__Actual position)) | UINT32 | RO | 0x6120:36, 32 |
1A61:22 | SubIndex 034 | 34. PDO Mapping entry (32 bits align) | UINT32 | RO | 0x0000:00, 32 |
1A61:23 | SubIndex 035 | 35. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x37 (DMC__Error id)) | UINT32 | RO | 0x6120:37, 32 |
1A61:24 | SubIndex 036 | 36. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x38 (DMC__Input cycle counter)) | UINT32 | RO | 0x6120:38, 8 |
1A61:25 | SubIndex 037 | 37. PDO Mapping entry (8 bits align) | UINT32 | RO | 0x0000:00, 8 |
1A61:26 | SubIndex 038 | 38. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x3A (DMC__Latch value)) | UINT32 | RO | 0x6120:3A, 32 |
1A61:27 | SubIndex 039 | 39. PDO Mapping entry (32 bits align) | UINT32 | RO | 0x0000:00, 32 |
1A61:28 | SubIndex 040 | 40. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x3B (DMC__Cyclic info data 1)) | UINT32 | RO | 0x6120:3B, 16 |
1A61:29 | SubIndex 041 | 41. PDO Mapping entry (object 0x6120 (DMC Inputs Ch.2), entry 0x3C (DMC__Cyclic info data 2)) | UINT32 | RO | 0x6120:3C, 16 |
1A61:2A | SubIndex 042 | 42. PDO Mapping entry (64 bits align) | UINT32 | RO | 0x0000:00, 64 |
Index 1A80 DRV TxPDO-Map Brake Chopper Inputs
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A80:0 | DRV TxPDO-Map Brake Chopper Inputs | PDO Mapping TxPDO 129 | UINT8 | RO | 0x07 (7dec) |
1A80:01 | SubIndex 001 | 1. PDO Mapping entry (2 bits align) | UINT32 | RO | 0x0000:00, 2 |
1A80:02 | SubIndex 002 | 2. PDO Mapping entry (object 0xF600 (DRV Brake Chopper Inputs), entry 0x03 (Brake chopper I2T warning)) | UINT32 | RO | 0xF600:03, 1 |
1A80:03 | SubIndex 003 | 3. PDO Mapping entry (2 bits align) | UINT32 | RO | 0x0000:00, 2 |
1A80:04 | SubIndex 004 | 4. PDO Mapping entry (object 0xF600 (DRV Brake Chopper Inputs), entry 0x06 (Brake chopper on)) | UINT32 | RO | 0xF600:06, 1 |
1A80:05 | SubIndex 005 | 5. PDO Mapping entry (10 bits align) | UINT32 | RO | 0x0000:00, 10 |
1A80:06 | SubIndex 006 | 6. PDO Mapping entry (object 0xF600 (DRV Brake Chopper Inputs), entry 0x11 (Brake chopper dutycycle)) | UINT32 | RO | 0xF600:11, 8 |
1A80:07 | SubIndex 007 | 7. PDO Mapping entry (object 0xF600 (DRV Brake Chopper Inputs), entry 0x12 (Brake chopper I2T utilisation)) | UINT32 | RO | 0xF600:12, 8 |
Index 1C00 Sync manager type
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1C00:0 | Sync manager type | Using the Sync Managers | UINT8 | RO | 0x04 (4dec) |
1C00:01 | SubIndex 001 | Sync-Manager Type Channel 1: Mailbox Write | UINT8 | RO | 0x01 (1dec) |
1C00:02 | SubIndex 002 | Sync-Manager Type Channel 2: Mailbox Read | UINT8 | RO | 0x02 (2dec) |
1C00:03 | SubIndex 003 | Sync-Manager Type Channel 3: Process Data Write (Outputs) | UINT8 | RO | 0x03 (3dec) |
1C00:04 | SubIndex 004 | Sync-Manager Type Channel 4: Process Data Read (Inputs) | UINT8 | RO | 0x04 (4dec) |
Index 1C12 RxPDO assign
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1C12:0 | RxPDO assign | PDO Assign Outputs | UINT8 | RW | 0x04 (4dec) |
1C12:01 | SubIndex 001 | 1. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x1610 (5648dec) |
1C12:02 | SubIndex 002 | 2. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x1611 (5649dec) |
1C12:03 | SubIndex 003 | 3. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x1650 (5712dec) |
1C12:04 | SubIndex 004 | 4. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x1651 (5713dec) |
1C12:05 | SubIndex 005 | 5. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:06 | SubIndex 006 | 6. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:07 | SubIndex 007 | 7. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:08 | SubIndex 008 | 8. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:09 | SubIndex 009 | 9. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:0A | SubIndex 010 | 10. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:0B | SubIndex 011 | 11. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:0C | SubIndex 012 | 12. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:0D | SubIndex 013 | 13. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:0E | SubIndex 014 | 14. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:0F | SubIndex 015 | 15. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:10 | SubIndex 016 | 16. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:11 | SubIndex 017 | 17. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:12 | SubIndex 018 | 18. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:13 | SubIndex 019 | 19. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:14 | SubIndex 020 | 20. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:15 | SubIndex 021 | 21. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:16 | SubIndex 022 | 22. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:17 | SubIndex 023 | 23. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:18 | SubIndex 024 | 24. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:19 | SubIndex 025 | 25. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:1A | SubIndex 026 | 26. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:1B | SubIndex 027 | 27. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:1C | SubIndex 028 | 28. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:1D | SubIndex 029 | 29. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:1E | SubIndex 030 | 30. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
Index 1C13 TxPDO assign
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1C13:0 | TxPDO assign | PDO Assign Inputs | UINT8 | RW | 0x06 (6dec) |
1C13:01 | SubIndex 001 | 1. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x1A00 (6656dec) |
1C13:02 | SubIndex 002 | 2. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x1A10 (6672dec) |
1C13:03 | SubIndex 003 | 3. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x1A11 (6673dec) |
1C13:04 | SubIndex 004 | 4. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x1A40 (6720dec) |
1C13:05 | SubIndex 005 | 5. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x1A50 (6736dec) |
1C13:06 | SubIndex 006 | 6. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x1A51 (6737dec) |
1C13:07 | SubIndex 007 | 7. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:08 | SubIndex 008 | 8. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:09 | SubIndex 009 | 9. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:0A | SubIndex 010 | 10. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:0B | SubIndex 011 | 11. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:0C | SubIndex 012 | 12. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:0D | SubIndex 013 | 13. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:0E | SubIndex 014 | 14. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:0F | SubIndex 015 | 15. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:10 | SubIndex 016 | 16. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:11 | SubIndex 017 | 17. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:12 | SubIndex 018 | 18. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:13 | SubIndex 019 | 19. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:14 | SubIndex 020 | 20. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:15 | SubIndex 021 | 21. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:16 | SubIndex 022 | 22. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:17 | SubIndex 023 | 23. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:18 | SubIndex 024 | 24. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:19 | SubIndex 025 | 25. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:1A | SubIndex 026 | 26. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:1B | SubIndex 027 | 27. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:1C | SubIndex 028 | 28. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:1D | SubIndex 029 | 29. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:1E | SubIndex 030 | 30. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:1F | SubIndex 031 | 31. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:20 | SubIndex 032 | 32. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:21 | SubIndex 033 | 33. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:22 | SubIndex 034 | 34. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:23 | SubIndex 035 | 35. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:24 | SubIndex 036 | 36. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:25 | SubIndex 037 | 37. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:26 | SubIndex 038 | 38. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:27 | SubIndex 039 | 39. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:28 | SubIndex 040 | 40. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:29 | SubIndex 041 | 41. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:2A | SubIndex 042 | 42. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:2B | SubIndex 043 | 43. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
Index 1C32 SM output parameter
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1C32:0 | SM output parameter | Synchronization parameters for the outputs | UINT8 | RO | 0x20 (32dec) |
1C32:01 | Sync mode | Current synchronization mode:
| UINT16 | RW | 0x0000 (0dec) |
1C32:02 | Cycle time | Cycle time (in ns):
| UINT32 | RW | 0x00000000 (0dec) |
1C32:03 | Shift time | Time between SYNC0 event and output of the outputs (in ns, DC mode only) | UINT32 | RO | 0x00000000 (0dec) |
1C32:04 | Sync modes supported | Supported synchronization modes: Bit 0 = 1: Free Run is supported Bit 1 = 1: Synchron with SM 2 Event is supported Bit 2-3 = 01: DC-Mode is supported Bit 4-5 = 10: Output Shift with SYNC1 Event (DC-Mode only) Bit 14 = 1: dynamic times (measurement through writing of 1C32:08) | UINT16 | RO | 0x0000 (0dec) |
1C32:05 | Minimum cycle time | Minimum cycle time (in ns) | UINT32 | RO | 0x00000000 (0dec) |
1C32:06 | Calc and copy time |
| UINT32 | RO | 0x00000000 (0dec) |
1C32:07 | Minimum delay time |
| UINT32 | RO | 0x00000000 (0dec) |
1C32:08 | Get Cycle Time |
Entries 1C32:03, 1C32:05, 1C32:06, 1C32:09, 1C33:03, 1C33:06, 1C33:09 are updated with the maximum measured values. For a subsequent measurement the measured values are reset | UINT16 | RW | 0x0000 (0dec) |
1C32:09 | Maximum delay time | Time between SYNC1 event and output of the outputs (in ns, DC mode only) | UINT32 | RO | 0x00000000 (0dec) |
1C32:0A | Sync0 Cycle Time |
| UINT32 | RO | 0x00000000 (0dec) |
1C32:0B | SM event missed counter | Number of missed SM events in OPERATIONAL (DC mode only) | UINT16 | RO | 0x0000 (0dec) |
1C32:0C | Cycle exceeded counter | Number of occasions the cycle time was exceeded in OPERATIONAL (cycle was not completed in time or the next cycle began too early) | UINT16 | RO | 0x0000 (0dec) |
1C32:0D | Shift too short counter | Number of occasions that the interval between SYNC0 and SYNC1 event was too short (DC mode only) | UINT16 | RO | 0x0000 (0dec) |
1C32:20 | Sync error | The synchronization was not correct in the last cycle (outputs were output too late; DC mode only) | BOOLEAN | RO | 0x00 (0dec) |
Index 1C33 SM input parameter
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1C33:0 | SM input parameter | Synchronization parameters for the inputs | UINT8 | RO | 0x20 (32dec) |
1C33:01 | Sync mode | Current synchronization mode:
| UINT16 | RW | 0x0000 (0dec) |
1C33:02 | Cycle time | as 1C32:02 | UINT32 | RW | 0x00000000 (0dec) |
1C33:03 | Shift time | Time between SYNC0 event and reading of the inputs (in ns, DC mode only) | UINT32 | RO | 0x00000000 (0dec) |
1C33:04 | Sync modes supported | Supported synchronization modes: Bit 0: Free Run is supported Bit 1: Synchron with SM 2 Event is supported (outputs available) Bit 1: Synchron with SM 3 Event is supported (no outputs available) Bit 2-3 = 01: DC-Mode is supported Bit 4-5 = 01: Input Shift through local event (outputs available) Bit 4-5 = 10: Input Shift with SYNC1 event (no outputs available) Bit 14 = 1: dynamic times (measurement through writing of 1C32:08 or 1C33:08) | UINT16 | RO | 0x0000 (0dec) |
1C33:05 | Minimum cycle time | as 1C32:05 | UINT32 | RO | 0x00000000 (0dec) |
1C33:06 | Calc and copy time | Time between reading of the inputs and availability of the inputs for the master (in ns, only DC mode) | UINT32 | RO | 0x00000000 (0dec) |
1C33:07 | Minimum delay time |
| UINT32 | RO | 0x00000000 (0dec) |
1C33:08 | Get Cycle Time | as 1C32:08 | UINT16 | RW | 0x0000 (0dec) |
1C33:09 | Maximum delay time | Time between SYNC1 event and reading of the inputs (in ns, only DC mode) | UINT32 | RO | 0x00000000 (0dec) |
1C33:0A | Sync0 Cycle Time |
| UINT32 | RO | 0x00000000 (0dec) |
1C33:0B | SM event missed counter | as 1C32:11 | UINT16 | RO | 0x0000 (0dec) |
1C33:0C | Cycle exceeded counter | as 1C32:12 | UINT16 | RO | 0x0000 (0dec) |
1C33:0D | Shift too short counter | as 1C32:13 | UINT16 | RO | 0x0000 (0dec) |
1C33:20 | Sync error | as 1C32:32 | BOOLEAN | RO | 0x00 (0dec) |
Index F000 Modular Device Profile
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
F000:0 | Modular Device Profile | General information for the modular device profile | UINT8 | RO | 0x02 (2dec) |
F000:01 | Index distance | Index distance of the objects of the individual channels | UINT16 | RO | 0x0010 (16dec) |
F000:02 | Maximum number of modules | Number of channels | UINT16 | RO | 0x0013 (19dec) |
Index F008 Code word
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
F008:0 | Code word |
| UINT32 | RW | 0x00000000 (0dec) |
Index F010 Module Profile List
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
F010:0 | Module Profile List |
| UINT8 | RO | 0x13 (19dec) |
F010:01 | SubIndex 001 |
| UINT32 | RO | 0x00000201 (513dec) |
F010:02 | SubIndex 002 |
| UINT32 | RO | 0x000002E6 (742dec) |
F010:03 | SubIndex 003 |
| UINT32 | RO | 0x000002EE (750dec) |
F010:04 | SubIndex 004 |
| UINT32 | RO | 0x00000000 (0dec) |
F010:05 | SubIndex 005 |
| UINT32 | RO | 0x00000000 (0dec) |
F010:06 | SubIndex 006 |
| UINT32 | RO | 0x00000000 (0dec) |
F010:07 | SubIndex 007 |
| UINT32 | RO | 0x00000000 (0dec) |
F010:08 | SubIndex 008 |
| UINT32 | RO | 0x00000000 (0dec) |
010F:09 | SubIndex 009 |
| UINT32 | RO | 0x00000000 (0dec) |
F010:0A | SubIndex 010 |
| UINT32 | RO | 0x00000000 (0dec) |
F010:0B | SubIndex 011 |
| UINT32 | RO | 0x00000000 (0dec) |
F010:0C | SubIndex 012 |
| UINT32 | RO | 0x00000000 (0dec) |
F010:0D | SubIndex 013 |
| UINT32 | RO | 0x00000000 (0dec) |
F010:0E | SubIndex 014 |
| UINT32 | RO | 0x00000000 (0dec) |
F010:0F | SubIndex 015 |
| UINT32 | RO | 0x00000000 (0dec) |
F010:10 | SubIndex 016 |
| UINT32 | RO | 0x00000000 (0dec) |
F010:11 | SubIndex 017 |
| UINT32 | RO | 0x00000201 (513dec) |
F010:12 | SubIndex 018 |
| UINT32 | RO | 0x000002E6 (742dec) |
F010:13 | SubIndex 019 |
| UINT32 | RO | 0x000002EE (750dec) |
Index F081 Download revision
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
F081:0 | Download revision |
| UINT8 | RO | 0x01 (1dec) |
F081:01 | Revision number |
| UINT32 | RW | 0x00000000 (0dec) |
Index FB40 Memory interface
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
FB40:0 | Memory interface |
| UINT8 | RO | 0x03 (3dec) |
FB40:01 | Address |
| UINT32 | RW | 0x00000000 (0dec) |
FB40:02 | Length |
| UINT16 | RW | 0x0000 (0dec) |
FB40:03 | Data |
| OCTET-STRING[8] | RW | {0} |