0x90nF PAI Calibration Dates Ch.[n+1]

Valid from revision 0017 on

0 ≤ n ≤ m, n+1 = Channel number, m+1 = max. No. of channels:

Index (hex)

Name

Meaning

Data type

Flags

Default

90nF:0

PAI Calibration Dates Ch.[n+1]

 

UINT8

RO

0xC4 (196dec)

90nF:01

Vendor U ±60 V

 

OCTET-STRING[4]

RO

{0}

90nF:02

Vendor U ±10 V

 

OCTET-STRING[4]

RO

{0}

90nF:03

Vendor U ±5 V

 

OCTET-STRING[4]

RO

{0}

90nF:04

Vendor U ±2.5 V

 

OCTET-STRING[4]

RO

{0}

90nF:05

Vendor U ±1.25 V

 

OCTET-STRING[4]

RO

{0}

90nF:06

Vendor U ±640 mV

 

OCTET-STRING[4]

RO

{0}

90nF:07

Vendor U ±320 mV

 

OCTET-STRING[4]

RO

{0}

90nF:08

Vendor U ±160 mV

 

OCTET-STRING[4]

RO

{0}

90nF:09

Vendor U ±80 mV

 

OCTET-STRING[4]

RO

{0}

90nF:0A

Vendor U ±40 mV

 

OCTET-STRING[4]

RO

{0}

90nF:0B

Vendor U ±20 mV

 

OCTET-STRING[4]

RO

{0}

90nF:0C

Vendor U 0..10 V

 

OCTET-STRING[4]

RO

{0}

90nF:0D

Vendor U 0..5 V

 

OCTET-STRING[4]

RO

{0}

90nF:0E

Vendor I ±20 mA

 

OCTET-STRING[4]

RO

{0}

90nF:0F

Vendor I 0..20 mA

 

OCTET-STRING[4]

RO

{0}

90nF:10

Vendor I 4..20 mA

 

OCTET-STRING[4]

RO

{0}

90nF:11

Vendor I 4..20 mA (NAMUR)

 

OCTET-STRING[4]

RO

{0}

90nF:12

Vendor Poti 3Wire

 

OCTET-STRING[4]

RO

{0}

90nF:13

Vendor Poti 5Wire

 

OCTET-STRING[4]

RO

{0}

90nF:14

Vendor TC 80 mV

 

OCTET-STRING[4]

RO

{0}

90nF:15

Vendor TC CJC

 

OCTET-STRING[4]

RO

{0}

90nF:16

Vendor TC CJC RTD

 

OCTET-STRING[4]

RO

{0}

90nF:17

Vendor IEPE ±10 V

 

OCTET-STRING[4]

RO

{0}

90nF:18

Vendor IEPE ±5 V

 

OCTET-STRING[4]

RO

{0}

90nF:19

Vendor IEPE ±2.5 V

 

OCTET-STRING[4]

RO

{0}

90nF:1A

Vendor IEPE 0..20 V

 

OCTET-STRING[4]

RO

{0}

90nF:1B

Vendor IEPE 0..10 V

 

OCTET-STRING[4]

RO

{0}

90nF:1C

Vendor SG Full-Bridge 4Wire 2 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:1D

Vendor SG Full-Bridge 4Wire 4 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:1E

Vendor SG Full-Bridge 4Wire 32 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:1F

Vendor SG Full-Bridge 6Wire 2 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:20

Vendor SG Full-Bridge 6Wire 4 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:21

Vendor SG Full-Bridge 6Wire 32 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:22

Vendor SG Half-Bridge 3Wire 2 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:23

Vendor SG Half-Bridge 3Wire 16 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:24

Vendor SG Half-Bridge 5Wire 2 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:25

Vendor SG Half-Bridge 5Wire 16 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:26

Vendor SG Quarter-Bridge 2Wire 120R 2 mV/V compensated

 

OCTET-STRING[4]

RO

{0}

90nF:27

Vendor SG Quarter-Bridge 2Wire 120R 4 mV/V compensated

 

OCTET-STRING[4]

RO

{0}

90nF:28

Vendor SG Quarter-Bridge 2Wire 120R 8 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:29

Vendor SG Quarter-Bridge 2Wire 120R 32 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:2A

Vendor SG Quarter-Bridge 3Wire 120R 2 mV/V compensated

 

OCTET-STRING[4]

RO

{0}

90nF:2B

Vendor SG Quarter-Bridge 3Wire 120R 4 mV/V compensated

 

OCTET-STRING[4]

RO

{0}

90nF:2C

Vendor SG Quarter-Bridge 3Wire 120R 8 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:2D

Vendor SG Quarter-Bridge 3Wire 120R 32 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:2E

Vendor SG Quarter-Bridge 2Wire 350R 2 mV/V compensated

 

OCTET-STRING[4]

RO

{0}

90nF:2F

Vendor SG Quarter-Bridge 2Wire 350R 4 mV/V compensated

 

OCTET-STRING[4]

RO

{0}

90nF:30

Vendor SG Quarter-Bridge 2Wire 350R 8 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:31

Vendor SG Quarter-Bridge 2Wire 350R 32 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:32

Vendor SG Quarter-Bridge 3Wire 350R 2 mV/V compensated

 

OCTET-STRING[4]

RO

{0}

90nF:33

Vendor SG Quarter-Bridge 3Wire 350R 4 mV/V compensated

 

OCTET-STRING[4]

RO

{0}

90nF:34

Vendor SG Quarter-Bridge 3Wire 350R 8 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:35

Vendor SG Quarter-Bridge 3Wire 350R 32 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:36

Vendor R/RTD 2Wire 5k

 

OCTET-STRING[4]

RO

{0}

90nF:37

Vendor R/RTD 3Wire 5k

 

OCTET-STRING[4]

RO

{0}

90nF:38

Vendor R/RTD 4Wire 5k

 

OCTET-STRING[4]

RO

{0}

90nF:39

Vendor R/RTD 2Wire 2k

 

OCTET-STRING[4]

RO

{0}

90nF:3A

Vendor R/RTD 3Wire 2k

 

OCTET-STRING[4]

RO

{0}

90nF:3B

Vendor R/RTD 4Wire 2k

 

OCTET-STRING[4]

RO

{0}

90nF:3C

Vendor R/RTD 2Wire 500R

 

OCTET-STRING[4]

RO

{0}

90nF:3D

Vendor R/RTD 3Wire 500R

 

OCTET-STRING[4]

RO

{0}

90nF:3E

Vendor R/RTD 4Wire 500R

 

OCTET-STRING[4]

RO

{0}

90nF:3F

Vendor R/RTD 2Wire 200R

 

OCTET-STRING[4]

RO

{0}

90nF:40

Vendor R/RTD 3Wire 200R

 

OCTET-STRING[4]

RO

{0}

90nF:41

Vendor R/RTD 4Wire 200R

 

OCTET-STRING[4]

RO

{0}

90nF:42

Vendor R/RTD 2Wire 50R

 

OCTET-STRING[4]

RO

{0}

90nF:43

Vendor R/RTD 3Wire 50R

 

OCTET-STRING[4]

RO

{0}

90nF:44

Vendor R/RTD 4Wire 50R

 

OCTET-STRING[4]

RO

{0}

90nF:81

User U ±60 V

 

OCTET-STRING[4]

RO

{0}

90nF:82

User U ±10 V

 

OCTET-STRING[4]

RO

{0}

90nF:83

User U ±5 V

 

OCTET-STRING[4]

RO

{0}

90nF:84

User U ±2.5 V

 

OCTET-STRING[4]

RO

{0}

90nF:85

User U ±1.25 V

 

OCTET-STRING[4]

RO

{0}

90nF:86

User U ±640 mV

 

OCTET-STRING[4]

RO

{0}

90nF:87

User U ±320 mV

 

OCTET-STRING[4]

RO

{0}

90nF:88

User U ±160 mV

 

OCTET-STRING[4]

RO

{0}

90nF:89

User U ±80 mV

 

OCTET-STRING[4]

RO

{0}

90nF:8A

User U ±40 mV

 

OCTET-STRING[4]

RO

{0}

90nF:8B

User U ±20 mV

 

OCTET-STRING[4]

RO

{0}

90nF:8C

User U 0..10 V

 

OCTET-STRING[4]

RO

{0}

90nF:8D

User U 0..5 V

 

OCTET-STRING[4]

RO

{0}

90nF:8E

User I ±20 mA

 

OCTET-STRING[4]

RO

{0}

90nF:8F

User I 0..20 mA

 

OCTET-STRING[4]

RO

{0}

90nF:90

User I 4..20 mA

 

OCTET-STRING[4]

RO

{0}

90nF:91

User I 4..20 mA (NAMUR)

 

OCTET-STRING[4]

RO

{0}

90nF:92

User Poti 3Wire

 

OCTET-STRING[4]

RO

{0}

90nF:93

User Poti 5Wire

 

OCTET-STRING[4]

RO

{0}

90nF:94

User TC 80 mV

 

OCTET-STRING[4]

RO

{0}

90nF:95

User TC CJC

 

OCTET-STRING[4]

RO

{0}

90nF:96

User TC CJC RTD

 

OCTET-STRING[4]

RO

{0}

90nF:97

User IEPE ±10 V

 

OCTET-STRING[4]

RO

{0}

90nF:98

User IEPE ±5 V

 

OCTET-STRING[4]

RO

{0}

90nF:99

User IEPE ±2.5 V

 

OCTET-STRING[4]

RO

{0}

90nF:9A

User IEPE 0..20 V

 

OCTET-STRING[4]

RO

{0}

90nF:9B

User IEPE 0..10 V

 

OCTET-STRING[4]

RO

{0}

90nF:9C

User SG Full-Bridge 4Wire 2 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:9D

User SG Full-Bridge 4Wire 4 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:9E

User SG Full-Bridge 4Wire 32 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:9F

User SG Full-Bridge 6Wire 2 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:A0

User SG Full-Bridge 6Wire 4 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:A1

User SG Full-Bridge 6Wire 32 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:A2

User SG Half-Bridge 3Wire 2 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:A3

User SG Half-Bridge 3Wire 16 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:A4

User SG Half-Bridge 5Wire 2 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:A5

User SG Half-Bridge 5Wire 16 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:A6

User SG Quarter-Bridge 2Wire 120R 2 mV/V compensated

 

OCTET-STRING[4]

RO

{0}

90nF:A7

User SG Quarter-Bridge 2Wire 120R 4 mV/V compensated

 

OCTET-STRING[4]

RO

{0}

90nF:A8

User SG Quarter-Bridge 2Wire 120R 8 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:A9

User SG Quarter-Bridge 2Wire 120R 32 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:AA

User SG Quarter-Bridge 3Wire 120R 2 mV/V compensated

 

OCTET-STRING[4]

RO

{0}

90nF:AB

User SG Quarter-Bridge 3Wire 120R 4 mV/V compensated

 

OCTET-STRING[4]

RO

{0}

90nF:AC

User SG Quarter-Bridge 3Wire 120R 8 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:AD

User SG Quarter-Bridge 3Wire 120R 32 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:AE

User SG Quarter-Bridge 2Wire 350R 2 mV/V compensated

 

OCTET-STRING[4]

RO

{0}

90nF:AF

User SG Quarter-Bridge 2Wire 350R 4 mV/V compensated

 

OCTET-STRING[4]

RO

{0}

90nF:B0

User SG Quarter-Bridge 2Wire 350R 8 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:B1

User SG Quarter-Bridge 2Wire 350R 32 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:B2

User SG Quarter-Bridge 3Wire 350R 2 mV/V compensated

 

OCTET-STRING[4]

RO

{0}

90nF:B3

User SG Quarter-Bridge 3Wire 350R 4 mV/V compensated

 

OCTET-STRING[4]

RO

{0}

90nF:B4

User SG Quarter-Bridge 3Wire 350R 8 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:B5

User SG Quarter-Bridge 3Wire 350R 32 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:B6

User R/RTD 2Wire 5k

 

OCTET-STRING[4]

RO

{0}

90nF:B7

User R/RTD 3Wire 5k

 

OCTET-STRING[4]

RO

{0}

90nF:B8

User R/RTD 4Wire 5k

 

OCTET-STRING[4]

RO

{0}

90nF:B9

User R/RTD 2Wire 2k

 

OCTET-STRING[4]

RO

{0}

90nF:BA

User R/RTD 3Wire 2k

 

OCTET-STRING[4]

RO

{0}

90nF:BB

User R/RTD 4Wire 2k

 

OCTET-STRING[4]

RO

{0}

90nF:BC

User R/RTD 2Wire 500R

 

OCTET-STRING[4]

RO

{0}

90nF:BD

User R/RTD 3Wire 500R

 

OCTET-STRING[4]

RO

{0}

90nF:BE

User R/RTD 4Wire 500R

 

OCTET-STRING[4]

RO

{0}

90nF:BF

User R/RTD 2Wire 200R

 

OCTET-STRING[4]

RO

{0}

90nF:C0

User R/RTD 3Wire 200R

 

OCTET-STRING[4]

RO

{0}

90nF:C1

User R/RTD 4Wire 200R

 

OCTET-STRING[4]

RO

{0}

90nF:C2

User R/RTD 2Wire 50R

 

OCTET-STRING[4]

RO

{0}

90nF:C3

User R/RTD 3Wire 50R

 

OCTET-STRING[4]

RO

{0}

90nF:C4

User R/RTD 4Wire 50R

 

OCTET-STRING[4]

RO

{0}

Valid up to and including revision 0016

0 ≤ n ≤ m, n+1 = Channel number, m+1 = max. No. of channels:

Index (hex)

Name

Meaning

Data type

Flags

Default

90nF:0

PAI Calibration Dates Ch.[n+1]

 

UINT8

RO

0xC3 (195dec)

90nF:01

Vendor U ±60 V

 

OCTET-STRING[4]

RO

{0}

90nF:02

Vendor U ±10 V

 

OCTET-STRING[4]

RO

{0}

90nF:03

Vendor U ±5 V

 

OCTET-STRING[4]

RO

{0}

90nF:04

Vendor U ±2.5 V

 

OCTET-STRING[4]

RO

{0}

90nF:05

Vendor U ±1.25 V

 

OCTET-STRING[4]

RO

{0}

90nF:06

Vendor U ±640 mV

 

OCTET-STRING[4]

RO

{0}

90nF:07

Vendor U ±320 mV

 

OCTET-STRING[4]

RO

{0}

90nF:08

Vendor U ±160 mV

 

OCTET-STRING[4]

RO

{0}

90nF:09

Vendor U ±80 mV

 

OCTET-STRING[4]

RO

{0}

90nF:0A

Vendor U ±40 mV

 

OCTET-STRING[4]

RO

{0}

90nF:0B

Vendor U ±20 mV

 

OCTET-STRING[4]

RO

{0}

90nF:0C

Vendor U 0..10 V

 

OCTET-STRING[4]

RO

{0}

90nF:0D

Vendor U 0..5 V

 

OCTET-STRING[4]

RO

{0}

90nF:0E

Vendor I ±20 mA

 

OCTET-STRING[4]

RO

{0}

90nF:0F

Vendor I 0..20 mA

 

OCTET-STRING[4]

RO

{0}

90nF:10

Vendor I 4..20 mA

 

OCTET-STRING[4]

RO

{0}

90nF:11

Vendor I 4..20 mA (NAMUR)

 

OCTET-STRING[4]

RO

{0}

90nF:12

Vendor Poti 3Wire

 

OCTET-STRING[4]

RO

{0}

90nF:13

Vendor Poti 5Wire

 

OCTET-STRING[4]

RO

{0}

90nF:14

Vendor TC 80 mV

 

OCTET-STRING[4]

RO

{0}

90nF:15

Vendor TC CJC

 

OCTET-STRING[4]

RO

{0}

90nF:16

Vendor IEPE ±10 V

 

OCTET-STRING[4]

RO

{0}

90nF:17

Vendor IEPE ±5 V

 

OCTET-STRING[4]

RO

{0}

90nF:18

Vendor IEPE ±2.5 V

 

OCTET-STRING[4]

RO

{0}

90nF:19

Vendor IEPE 0..20 V

 

OCTET-STRING[4]

RO

{0}

90nF:1A

Vendor IEPE 0..10 V

 

OCTET-STRING[4]

RO

{0}

90nF:1B

Vendor SG Full-Bridge 4Wire 2 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:1C

Vendor SG Full-Bridge 4Wire 4 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:1D

Vendor SG Full-Bridge 4Wire 32 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:1E

Vendor SG Full-Bridge 6Wire 2 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:1F

Vendor SG Full-Bridge 6Wire 4 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:20

Vendor SG Full-Bridge 6Wire 32 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:21

Vendor SG Half-Bridge 3Wire 2 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:22

Vendor SG Half-Bridge 3Wire 16 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:23

Vendor SG Half-Bridge 5Wire 2 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:24

Vendor SG Half-Bridge 5Wire 16 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:25

Vendor SG Quarter-Bridge 2Wire 120R 2 mV/V compensated

 

OCTET-STRING[4]

RO

{0}

90nF:26

Vendor SG Quarter-Bridge 2Wire 120R 4 mV/V compensated

 

OCTET-STRING[4]

RO

{0}

90nF:27

Vendor SG Quarter-Bridge 2Wire 120R 8 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:28

Vendor SG Quarter-Bridge 2Wire 120R 32 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:29

Vendor SG Quarter-Bridge 3Wire 120R 2 mV/V compensated

 

OCTET-STRING[4]

RO

{0}

90nF:2A

Vendor SG Quarter-Bridge 3Wire 120R 4 mV/V compensated

 

OCTET-STRING[4]

RO

{0}

90nF:2B

Vendor SG Quarter-Bridge 3Wire 120R 8 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:2C

Vendor SG Quarter-Bridge 3Wire 120R 32 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:2D

Vendor SG Quarter-Bridge 2Wire 350R 2 mV/V compensated

 

OCTET-STRING[4]

RO

{0}

90nF:2E

Vendor SG Quarter-Bridge 2Wire 350R 4 mV/V compensated

 

OCTET-STRING[4]

RO

{0}

90nF:2F

Vendor SG Quarter-Bridge 2Wire 350R 8 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:30

Vendor SG Quarter-Bridge 2Wire 350R 32 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:31

Vendor SG Quarter-Bridge 3Wire 350R 2 mV/V compensated

 

OCTET-STRING[4]

RO

{0}

90nF:32

Vendor SG Quarter-Bridge 3Wire 350R 4 mV/V compensated

 

OCTET-STRING[4]

RO

{0}

90nF:33

Vendor SG Quarter-Bridge 3Wire 350R 8 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:34

Vendor SG Quarter-Bridge 3Wire 350R 32 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:35

Vendor R/RTD 2Wire 5k

 

OCTET-STRING[4]

RO

{0}

90nF:36

Vendor R/RTD 3Wire 5k

 

OCTET-STRING[4]

RO

{0}

90nF:37

Vendor R/RTD 4Wire 5k

 

OCTET-STRING[4]

RO

{0}

90nF:38

Vendor R/RTD 2Wire 2k

 

OCTET-STRING[4]

RO

{0}

90nF:39

Vendor R/RTD 3Wire 2k

 

OCTET-STRING[4]

RO

{0}

90nF:3A

Vendor R/RTD 4Wire 2k

 

OCTET-STRING[4]

RO

{0}

90nF:3B

Vendor R/RTD 2Wire 500R

 

OCTET-STRING[4]

RO

{0}

90nF:3C

Vendor R/RTD 3Wire 500R

 

OCTET-STRING[4]

RO

{0}

90nF:3D

Vendor R/RTD 4Wire 500R

 

OCTET-STRING[4]

RO

{0}

90nF:3E

Vendor R/RTD 2Wire 200R

 

OCTET-STRING[4]

RO

{0}

90nF:3F

Vendor R/RTD 3Wire 200R

 

OCTET-STRING[4]

RO

{0}

90nF:40

Vendor R/RTD 4Wire 200R

 

OCTET-STRING[4]

RO

{0}

90nF:41

Vendor R/RTD 2Wire 50R

 

OCTET-STRING[4]

RO

{0}

90nF:42

Vendor R/RTD 3Wire 50R

 

OCTET-STRING[4]

RO

{0}

90nF:43

Vendor R/RTD 4Wire 50R

 

OCTET-STRING[4]

RO

{0}

90nF:81

User U ±60 V

 

OCTET-STRING[4]

RO

{0}

90nF:82

User U ±10 V

 

OCTET-STRING[4]

RO

{0}

90nF:83

User U ±5 V

 

OCTET-STRING[4]

RO

{0}

90nF:84

User U ±2.5 V

 

OCTET-STRING[4]

RO

{0}

90nF:85

User U ±1.25 V

 

OCTET-STRING[4]

RO

{0}

90nF:86

User U ±640 mV

 

OCTET-STRING[4]

RO

{0}

90nF:87

User U ±320 mV

 

OCTET-STRING[4]

RO

{0}

90nF:88

User U ±160 mV

 

OCTET-STRING[4]

RO

{0}

90nF:89

User U ±80 mV

 

OCTET-STRING[4]

RO

{0}

90nF:8A

User U ±40 mV

 

OCTET-STRING[4]

RO

{0}

90nF:8B

User U ±20 mV

 

OCTET-STRING[4]

RO

{0}

90nF:8C

User U 0..10 V

 

OCTET-STRING[4]

RO

{0}

90nF:8D

User U 0..5 V

 

OCTET-STRING[4]

RO

{0}

90nF:8E

User I ±20 mA

 

OCTET-STRING[4]

RO

{0}

90nF:8F

User I 0..20 mA

 

OCTET-STRING[4]

RO

{0}

90nF:90

User I 4..20 mA

 

OCTET-STRING[4]

RO

{0}

90nF:91

User I 4..20 mA (NAMUR)

 

OCTET-STRING[4]

RO

{0}

90nF:92

User Poti 3Wire

 

OCTET-STRING[4]

RO

{0}

90nF:93

User Poti 5Wire

 

OCTET-STRING[4]

RO

{0}

90nF:94

User TC 80 mV

 

OCTET-STRING[4]

RO

{0}

90nF:95

User TC CJC

 

OCTET-STRING[4]

RO

{0}

90nF:96

User IEPE ±10 V

 

OCTET-STRING[4]

RO

{0}

90nF:97

User IEPE ±5 V

 

OCTET-STRING[4]

RO

{0}

90nF:98

User IEPE ±2.5 V

 

OCTET-STRING[4]

RO

{0}

90nF:99

User IEPE 0..20 V

 

OCTET-STRING[4]

RO

{0}

90nF:9A

User IEPE 0..10 V

 

OCTET-STRING[4]

RO

{0}

90nF:9B

User SG Full-Bridge 4Wire 2 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:9C

User SG Full-Bridge 4Wire 4 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:9D

User SG Full-Bridge 4Wire 32 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:9E

User SG Full-Bridge 6Wire 2 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:9F

User SG Full-Bridge 6Wire 4 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:A0

User SG Full-Bridge 6Wire 32 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:A1

User SG Half-Bridge 3Wire 2 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:A2

User SG Half-Bridge 3Wire 16 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:A3

User SG Half-Bridge 5Wire 2 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:A4

User SG Half-Bridge 5Wire 16 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:A5

User SG Quarter-Bridge 2Wire 120R 2 mV/V compensated

 

OCTET-STRING[4]

RO

{0}

90nF:A6

User SG Quarter-Bridge 2Wire 120R 4 mV/V compensated

 

OCTET-STRING[4]

RO

{0}

90nF:A7

User SG Quarter-Bridge 2Wire 120R 8 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:A8

User SG Quarter-Bridge 2Wire 120R 32 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:A9

User SG Quarter-Bridge 3Wire 120R 2 mV/V compensated

 

OCTET-STRING[4]

RO

{0}

90nF:AA

User SG Quarter-Bridge 3Wire 120R 4 mV/V compensated

 

OCTET-STRING[4]

RO

{0}

90nF:AB

User SG Quarter-Bridge 3Wire 120R 8 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:AC

User SG Quarter-Bridge 3Wire 120R 32 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:AD

User SG Quarter-Bridge 2Wire 350R 2 mV/V compensated

 

OCTET-STRING[4]

RO

{0}

90nF:AE

User SG Quarter-Bridge 2Wire 350R 4 mV/V compensated

 

OCTET-STRING[4]

RO

{0}

90nF:AF

User SG Quarter-Bridge 2Wire 350R 8 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:B0

User SG Quarter-Bridge 2Wire 350R 32 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:B1

User SG Quarter-Bridge 3Wire 350R 2 mV/V compensated

 

OCTET-STRING[4]

RO

{0}

90nF:B2

User SG Quarter-Bridge 3Wire 350R 4 mV/V compensated

 

OCTET-STRING[4]

RO

{0}

90nF:B3

User SG Quarter-Bridge 3Wire 350R 8 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:B4

User SG Quarter-Bridge 3Wire 350R 32 mV/V

 

OCTET-STRING[4]

RO

{0}

90nF:B5

User R/RTD 2Wire 5k

 

OCTET-STRING[4]

RO

{0}

90nF:B6

User R/RTD 3Wire 5k

 

OCTET-STRING[4]

RO

{0}

90nF:B7

User R/RTD 4Wire 5k

 

OCTET-STRING[4]

RO

{0}

90nF:B8

User R/RTD 2Wire 2k

 

OCTET-STRING[4]

RO

{0}

90nF:B9

User R/RTD 3Wire 2k

 

OCTET-STRING[4]

RO

{0}

90nF:BA

User R/RTD 4Wire 2k

 

OCTET-STRING[4]

RO

{0}

90nF:BB

User R/RTD 2Wire 500R

 

OCTET-STRING[4]

RO

{0}

90nF:BC

User R/RTD 3Wire 500R

 

OCTET-STRING[4]

RO

{0}

90nF:BD

User R/RTD 4Wire 500R

 

OCTET-STRING[4]

RO

{0}

90nF:BE

User R/RTD 2Wire 200R

 

OCTET-STRING[4]

RO

{0}

90nF:BF

User R/RTD 3Wire 200R

 

OCTET-STRING[4]

RO

{0}

90nF:C0

User R/RTD 4Wire 200R

 

OCTET-STRING[4]

RO

{0}

90nF:C1

User R/RTD 2Wire 50R

 

OCTET-STRING[4]

RO

{0}

90nF:C2

User R/RTD 3Wire 50R

 

OCTET-STRING[4]

RO

{0}

90nF:C3

User R/RTD 4Wire 50R

 

OCTET-STRING[4]

RO

{0}