0x90nF PAI Calibration Dates Ch.[n+1]
0 ≤ n ≤ m, n+1 = Channel number, m+1 = max. No. of channels:
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
90nF:0 | PAI Calibration Dates Ch.[n+1] |
| UINT8 | RO | 0x94 (148dec) |
90nF:11 | Vendor I ±20 mA |
| OCTET-STRING[4] | RO | {0} |
90nF:12 | Vendor I 0…20 mA |
| OCTET-STRING[4] | RO | {0} |
90nF:13 | Vendor I 4…20 mA |
| OCTET-STRING[4] | RO | {0} |
90nF:14 | Vendor I 4…20 mA (NAMUR) |
| OCTET-STRING[4] | RO | {0} |
90nF:91 | User I ±20 mA |
| OCTET-STRING[4] | RO | {0} |
90nF:92 | User I 0…20 mA |
| OCTET-STRING[4] | RO | {0} |
90nF:93 | User I 4…20 mA |
| OCTET-STRING[4] | RO | {0} |
90nF:94 | User I 4…20 mA (NAMUR) |
| OCTET-STRING[4] | RO | {0} |