Configuration data (vendor-specific)

Index 800F Vendor data

Index (hex)

Name

Meaning

Data type

Flags

Default

800F:0

Vendor data

Max. Subindex

UINT8

RO

0x19 (25dec)

800F:11

Voltage In Calibration Offset

Input voltage offset (vendor calibration)

INT16

RW

0x0000 (0dec)

800F:12

Voltage In Calibration Gain

Input voltage gain (vendor calibration)

UINT16

RW

0x4000 (16384dec)

800F:15

Current Calibration Offset

Current offset (vendor calibration)

INT16

RW

0x0000 (0dec)

800F:16

Current Calibration Gain

Current gain (vendor calibration)

UINT16

RW

0x4000 (16384dec)

800F:17

Default Nominal Current

Nominal current at delivery or after reset to factory settings

UINT16

RW

---

800F:18

Max Nominal Current

Maximum nominal current

UINT16

RW

---

800F:19

Nominal Current Type

Nominal current adjustment option: adjustable or fixed

UINT16

RW

---