F000 - F915 (Device - Information and diagnostics)
Index F000 Modular device profile
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
F000:0 | Modular device profile | General information for the Modular Device Profile | UINT8 | RO | 0x02 (2dec) |
F000:01 | Module index distance | Index distance of the objects of the individual channels | UINT16 | RO | 0x0010 (16dec) |
F000:02 | Maximum number of modules | Number of channels | UINT16 | RO | 0x000C (12dec) |
Index F008 Code word
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
F008:0 | Code word | reserved | UINT32 | RW | 0x00000000 (0dec) |
Index F009 Password protection
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
F009:0 | Password protection | Password protection user calibration | UINT32 | RW | 0x00000000 (0dec) |
Index F010 Module list
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
F010:0 | Module list | Maximum subindex | UINT8 | RW | 0x0C (12dec) |
F010:01 | SubIndex 001 | reserved | UINT32 | RW | 0x000001FF (511dec) |
F010:02 | SubIndex 002 | reserved | UINT32 | RW | 0x00000000 (0dec) |
F010:03 | SubIndex 003 | reserved | UINT32 | RW | 0x00000000 (0dec) |
F010:04 | SubIndex 004 | reserved | UINT32 | RW | 0x00000000 (0dec) |
F010:05 | SubIndex 005 | reserved | UINT32 | RW | 0x00000065 (101dec) |
F010:06 | SubIndex 006 | reserved | UINT32 | RW | 0x00000065 (101dec) |
F010:07 | SubIndex 007 | reserved | UINT32 | RW | 0x00000065 (101dec) |
F010:08 | SubIndex 008 | reserved | UINT32 | RW | 0x00000065 (101dec) |
F010:09 | SubIndex 009 | reserved | UINT32 | RW | 0x000000FA (250dec) |
F010:0A | SubIndex 010 | reserved | UINT32 | RW | 0x000000FA (250dec) |
F010:0B | SubIndex 011 | reserved | UINT32 | RW | 0x0000012C (300dec) |
F010:0C | SubIndex 012 | reserved | UINT32 | RW | 0x00000190 (400dec) |
Index F030 Configured Module List
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
F030:0 | Configured Module List | Maximum subindex | UINT8 | RW | 0x0C (12dec) |
F030:01 | SubIndex 001 | reserved | UINT32 | RW | 0x00482199 (4727193dec) |
F030:02 | SubIndex 002 | reserved | UINT32 | RW | 0x00000000 (0dec) |
F030:03 | SubIndex 003 | reserved | UINT32 | RW | 0x00000000 (0dec) |
F030:04 | SubIndex 004 | reserved | UINT32 | RW | 0x00000000 (0dec) |
F030:05 | SubIndex 005 | reserved | UINT32 | RW | 0x00082199 (532889dec) |
F030:06 | SubIndex 006 | reserved | UINT32 | RW | 0x00082199 (532889dec) |
F030:07 | SubIndex 007 | reserved | UINT32 | RW | 0x00082199 (532889dec) |
F030:08 | SubIndex 008 | reserved | UINT32 | RW | 0x00082199 (532889dec) |
F030:09 | SubIndex 009 | reserved | UINT32 | RW | 0x00202199 (2105753dec) |
F030:0A | SubIndex 010 | reserved | UINT32 | RW | 0x00202199 (2105753dec) |
F030:0B | SubIndex 011 | reserved | UINT32 | RW | 0x00302199 (3154329dec) |
F030:0C | SubIndex 012 | reserved | UINT32 | RW | 0x00602199 (6300057dec) |
Index F050 Detected Module List
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
F050:0 | Detected Module list | Maximum subindex | UINT8 | RW | 0x0C (12dec) |
F050:01 | SubIndex 001 | reserved | UINT32 | RW | 0x00482199 (4727193dec) |
F050:02 | SubIndex 002 | reserved | UINT32 | RW | 0x00000000 (0dec) |
F050:03 | SubIndex 003 | reserved | UINT32 | RW | 0x00000000 (0dec) |
F050:04 | SubIndex 004 | reserved | UINT32 | RW | 0x00000000 (0dec) |
F050:05 | SubIndex 005 | reserved | UINT32 | RW | 0x00082199 (532889dec) |
F050:06 | SubIndex 006 | reserved | UINT32 | RW | 0x00082199 (532889dec) |
F050:07 | SubIndex 007 | reserved | UINT32 | RW | 0x00082199 (532889dec) |
F050:08 | SubIndex 008 | reserved | UINT32 | RW | 0x00082199 (532889dec) |
F050:09 | SubIndex 009 | reserved | UINT32 | RW | 0x00202199 (2105753dec) |
F050:0A | SubIndex 010 | reserved | UINT32 | RW | 0x00202199 (2105753dec) |
F050:0B | SubIndex 011 | reserved | UINT32 | RW | 0x00302199 (3154329dec) |
F050:0C | SubIndex 012 | reserved | UINT32 | RW | 0x00602199 (6300057dec) |
Index F081 Download revision
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
F081:0 | Download revision | Download revision | UINT8 | RO | 0x01 (1dec) |
F081:01 | Revision number | Revision number of the EtherCAT device Relevant as a startup list entry for compatibility | UINT32 | RW | 0x00000000 (0dec) |
Index F600 Device Inputs
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
F600:0 | Device Inputs | Maximum subindex | UINT8 | RW | 0x0F (15dec) |
F600:0D | Diag | Indicates that a new message is available in the "Diag History". | BOOLEAN | RO | 0x00 (0dec) |
F600:0E | TxPDO State | Validity of the data of the associated TxPDO (0 = valid, 1 = invalid). | BOOLEAN | RO | 0x00 (0dec) |
F600:0F | Input cycle counter | 2-bit counter for synchronization (incremented only if a new value is present) | BIT2 | RW | 0x00 (0dec) |
Index F915 LED Status
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
F915:0 | LED Status | Maximum subindex | UINT8 | RO | 0x10 (16dec) |
F915:01 | Error | reserved | UINT32 | RO | 0x00000000 (0dec) |
F915:02 | DI/ENC A/CNT Clk | reserved | UINT32 | RO | 0x00000000 (0dec) |
F915:03 | DI/ENC B/CNT Dir | reserved | UINT32 | RO | 0x00000000 (0dec) |
F915:04 | DI/Latch/Thr. Out/DO | reserved | UINT32 | RO | 0x00000000 (0dec) |
F915:05 | DI/Gate/DO | reserved | UINT32 | RO | 0x00000000 (0dec) |
F915:06 | PWM 1/DO | reserved | UINT32 | RO | 0x00000000 (0dec) |
F915:07 | AI | reserved | UINT32 | RO | 0x00000000 (0dec) |
F915:08 | Error AI | reserved | UINT32 | RO | 0x00000000 (0dec) |
F915:09 | RUN | reserved | UINT32 | RO | 0x00000000 (0dec) |
F915:0A | DI 1 | reserved | UINT32 | RO | 0x00000000 (0dec) |
F915:0B | DI 2 | reserved | UINT32 | RO | 0x00000000 (0dec) |
F915:0C | DI 3 | reserved | UINT32 | RO | 0x00000000 (0dec) |
F915:0D | DI 4 | reserved | UINT32 | RO | 0x00000000 (0dec) |
F915:0E | PWM 2/DO | reserved | UINT32 | RO | 0x00000000 (0dec) |
F915:0F | AO | reserved | UINT32 | RO | 0x00000000 (0dec) |
F915:10 | Error AO | reserved | UINT32 | RO | 0x00000000 (0dec) |