Information data, diagnostic data
Index 9010 DRV Info data
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
9010:0 | DRV Info data | Amplifier information data | UINT8 | RO | 0x15 (21dec) |
9010:11 | Amplifier temperature | Internal terminal temperature [0.1 °C] | INT16 | RO | 0x0000 (0dec) |
9010:12 | DC link voltage | DC link voltage [mV] | UINT32 | RO | 0x00000000 (0dec) |
9010:13 | Supported drive modes | Information about supported drive modes. (DS402: Object 0x6502) Only modes CSP, CSV, CST and CSTCA are supported. Bit 0: PP Bit 1: VL Bit 2: PV Bit 3: TQ Bit 4: R Bit 5: HM Bit 6: IP Bit 7: CSP Bit 8: CSV Bit 9: CST Bit 10: CSTCA Bit 11 - 15: reserved Bit 16-31: manufacturer-specific | UINT32 | RO | 0x00000000 (0dec) |
9010:14 | Velocity encoder resolution | Velocity encoder resolution [Inc/(U/s)] | UINT32 | RO | 0x00000000 (0dec) |
9010:15 | Position encoder resolution increments | Encoder increments per motor revolution (Compare 8008:13 Encoder increments per revolution for FOC. In the Six-Step operation modes: 65536) | UINT32 | RO | 0x00000000 (0dec) |
Index A010 DRV Amplifier Diag data
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
A010:0 | DRV Amplifier Diag data | Amplifier diagnosis data | UINT8 | RO | 0x11 (17dec) |
A010:11 | Amplifier I2T temperature | Amplifier I²T model utilization [%] | UINT8 | RO | 0x00 (0dec) |
Index A011 DRV Motor Diag data
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
A011:0 | DRV Motor Diag data | Motor diagnosis data | UINT8 | RO | 0x11 (17dec) |
A011:11 | Motor I2T temperature | Motor I²T model utilization [%] | UINT8 | RO | 0x00 (0dec) |
Index FB40 Memory interface
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
FB40:0 | Memory interface |
| UINT8 | RO | 0x03 (3dec) |
FB40:01 | Address |
| UINT32 | RW | 0x00000000 (0dec) |
FB40:02 | Length |
| UINT16 | RW | 0x0000 (0dec) |
FB40:03 | Data |
| OCTET-STRING[8] | RW | {0} |