Information and diagnosis data (device-specific)
Index 10F3 Diagnosis History
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
---|---|---|---|---|---|
10F3:0 |
Diagnosis History |
Maximum subindex |
UINT8 |
RO |
0x37 (55dec) |
10F3:01 |
Maximum Messages |
Maximum number of stored messages |
UINT8 |
RO |
0x00 (0dec) |
10F3:02 |
Newest Message |
Subindex of the latest message |
UINT8 |
RO |
0x00 (0dec) |
10F3:03 |
Newest Acknowledged Message |
Subindex of the last confirmed message |
UINT8 |
RW |
0x00 (0dec) |
10F3:04 |
New Messages Available |
Indicates that a new message is available. |
BOOLEAN |
RO |
0x00 (0dec) |
10F3:05 |
Flags |
not used |
UINT16 |
RW |
0x0000 (0dec) |
10F3:06 |
Diagnosis Message 001 |
Message 1 |
OCTET-STRING[28] |
RO |
{0} |
... |
... |
|
... |
... |
... |
10F3:37 |
Diagnosis Message 050 |
Message 50 |
OCTET-STRING[28] |
RO |
{0} |
Index 10F8 Actual Time Stamp
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
---|---|---|---|---|---|
10F8:0 |
Actual Time Stamp |
Time stamp |
UINT64 |
RO |
|
Index F900 DCM Info data
Index (hex) | Name | Meaning | Data type | Flags | Default |
---|---|---|---|---|---|
F900:0 | DCM Info data | Max. Subindex | UINT8 | RO | 0x06 (6dec) |
F900:01 | Software version (driver) | Software version of the driver card | STRING | RO |
|
F900:02 | Internal temperature | Internal terminal temperature | INT8 | RO | 0x00 (0dec) |
F900:04 | Control voltage | Control voltage | UINT16 | RO | 0x0000 (0dec) |
F900:05 | Motor supply voltage | Load voltage | UINT16 | RO | 0x0000 (0dec) |
F900:06 | Cycle time | Measured cycle time | UINT16 | RO | 0x0000 (0dec) |
Index FB40 Memory interface
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
---|---|---|---|---|---|
FB40:0 |
Memory interface |
Maximum subindex |
UINT8 |
RO |
0x03 (3dec) |
FB40:01 |
Address |
reserved |
UINT32 |
RW |
0x00000000 (0dec) |
FB40:02 |
Length |
reserved |
UINT16 |
RW |
0x0000 (0dec) |
FB40:03 |
Data |
reserved |
OCTET-STRING[8] |
RW |
{0} |