EL7031 - General connection examples
| |
Risk of injury through electric shock and damage to the device! Bring the Bus Terminals system into a safe, de-energized state before starting mounting, disassembly or wiring of the Bus Terminals. |
Notice | |
Connect the motor strands correctly! Connect the windings of a motor strand only to the terminal points of the same output driver of the stepper motor terminal, e.g.: - one motor strand to terminal points A1 and A2, - the other motor strand to terminal points B1 and B2. Connecting a motor strand to the terminal points of different output drivers (e.g. to A1 and B1) can lead to destruction of the output drivers of stepper motor terminal! |
Notice | |
Fuse protection of the supply voltage The electrical protection of the load voltage must be selected in such a way that the maximum flowing current is limited to 3 times the rated current (max. 1 second)! |
Connection types
The EL7031 Stepper Motor terminal has bipolar output stages and can control bipolar and unipolar motors.
Bipolar motors
![EL7031 - General connection examples 1:](Images/gif/2325677451__en-US__Web.gif)
![]() | Documentation for stepper motors from Beckhoff These two examples show the connection of the bipolar Beckhoff motors AS1010, AS1020 or AS1030. |
Unipolar motors
![EL7031 - General connection examples 3:](Images/gif/2257998731__Web.gif)
only one half of each winding is controlled.