Diagnostic objects

Index 9010 DRV Info data Ch.1

Index (hex)

Name

Meaning

Data type

Flags

Default

9010:0

DRV Info data Ch.1

 

UINT8

RO

0x28 (40dec))

9010:13

Supported drive modes

 

UINT32

RO

0x00000000 (0dec))

9010:14

Velocity encoder resolution

 

UINT32

RO

0x00000000 (0dec))

9010:15

Position encoder resolution increments

 

UINT32

RO

0x00000000 (0dec))

9010:16

Position encoder resolution revolutions

 

UINT32

RO

0x00000000 (0dec))

9010:17

Cogging compensation supported

 

BOOLEAN

RO

0x00 (0dec))

9010:27

Output stage safety state

permitted values:

  • 0: safe_state
  • 1: ready_state

UINT8

RO

0x00 (0dec))

9010:28

Actual motor brake state

permitted values:

  • 0: Motor brake applied
  • 1: Motor brake released

UINT8

RO

0x00 (0dec))

Index 9110 DRV Info data Ch.2

Index (hex)

Name

Meaning

Data type

Flags

Default

9110:0

DRV Info data Ch.2

 

UINT8

RO

0x28 (40dec))

9110:13

Supported drive modes

 

UINT32

RO

0x00000000 (0dec))

9110:14

Velocity encoder resolution

 

UINT32

RO

0x00000000 (0dec))

9110:15

Position encoder resolution increments

 

UINT32

RO

0x00000000 (0dec))

9110:16

Position encoder resolution revolutions

 

UINT32

RO

0x00000000 (0dec))

9110:17

Cogging compensation supported

 

BOOLEAN

RO

0x00 (0dec))

9110:27

Output stage safety state

permitted values:

  • 0: safe_state
  • 1: ready_state

UINT8

RO

0x00 (0dec))

9110:28

Actual motor brake state

permitted values:

  • 0: Motor brake applied
  • 1: Motor brake released

UINT8

RO

0x00 (0dec))

Index F900 DRV Info data

Index (hex)

Name

Meaning

Data type

Flags

Default

F900:0

DRV Info data

 

UINT8

RO

0x13 (19dec))

F900:11

Amplifier temperature

 

INT16

RO

0x0000 (0dec))

F900:12

DC link voltage

 

UINT32

RO

0x00000000 (0dec))

F900:13

Supply voltage Up

 

UINT32

RO

0x00000000 (0dec))

Index F913 DRV Device Info data

Index (hex)

Name

Meaning

Data type

Flags

Default

F913:0

DRV Device Info data

 

UINT8

RO

0x04 (4dec))

F913:01

HW config

 

STRING

RO

 

F913:02

FB config

 

STRING

RO

 

F913:03

FW info

 

STRING

RO

 

F913:04

DMC version

 

STRING

RO