Diagnostic objects
Index 9010 DRV Info data Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
9010:0 | DRV Info data Ch.1 |
| UINT8 | RO | 0x28 (40dec)) |
9010:13 | Supported drive modes |
| UINT32 | RO | 0x00000000 (0dec)) |
9010:14 | Velocity encoder resolution |
| UINT32 | RO | 0x00000000 (0dec)) |
9010:15 | Position encoder resolution increments |
| UINT32 | RO | 0x00000000 (0dec)) |
9010:16 | Position encoder resolution revolutions |
| UINT32 | RO | 0x00000000 (0dec)) |
9010:17 | Cogging compensation supported |
| BOOLEAN | RO | 0x00 (0dec)) |
9010:27 | Output stage safety state | permitted values:
| UINT8 | RO | 0x00 (0dec)) |
9010:28 | Actual motor brake state | permitted values:
| UINT8 | RO | 0x00 (0dec)) |
Index 9110 DRV Info data Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
9110:0 | DRV Info data Ch.2 |
| UINT8 | RO | 0x28 (40dec)) |
9110:13 | Supported drive modes |
| UINT32 | RO | 0x00000000 (0dec)) |
9110:14 | Velocity encoder resolution |
| UINT32 | RO | 0x00000000 (0dec)) |
9110:15 | Position encoder resolution increments |
| UINT32 | RO | 0x00000000 (0dec)) |
9110:16 | Position encoder resolution revolutions |
| UINT32 | RO | 0x00000000 (0dec)) |
9110:17 | Cogging compensation supported |
| BOOLEAN | RO | 0x00 (0dec)) |
9110:27 | Output stage safety state | permitted values:
| UINT8 | RO | 0x00 (0dec)) |
9110:28 | Actual motor brake state | permitted values:
| UINT8 | RO | 0x00 (0dec)) |
Index F900 DRV Info data
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
F900:0 | DRV Info data |
| UINT8 | RO | 0x13 (19dec)) |
F900:11 | Amplifier temperature |
| INT16 | RO | 0x0000 (0dec)) |
F900:12 | DC link voltage |
| UINT32 | RO | 0x00000000 (0dec)) |
F900:13 | Supply voltage Up |
| UINT32 | RO | 0x00000000 (0dec)) |
Index F913 DRV Device Info data
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
F913:0 | DRV Device Info data |
| UINT8 | RO | 0x04 (4dec)) |
F913:01 | HW config |
| STRING | RO |
|
F913:02 | FB config |
| STRING | RO |
|
F913:03 | FW info |
| STRING | RO |
|
F913:04 | DMC version |
| STRING | RO |
|