Function-specific technical data
Overview | |
|---|---|
Number of channels | 2 |
Inputs per channel | 2 x Digital latch input 1 x Encoder input |
Digital outputs per channel | 1 x Stepper motor 1 x Brake |
Motor | |
|---|---|
Motor type | Stepper motor, unipolar or bipolar |
Motor supply | 8 ... 48 VDC |
Output current | Without fan:
With ZB8610 fan cartridge:
|
Step frequency | max. 16,000 full steps/s |
Current controller frequency | 32 kHz |
Microstepping | 16384 intermediate steps per full step |
Encoder | |
|---|---|
Encoder type | Incremental encoders |
Input signal | 5 V differential or single-ended/open collector |
Signals | A, B, zero pulse, latch |
Input frequency with 4-fold evaluation | Depending on the type of input signal, see chapter Selection of motor and feedback. |
Encoder supply | 5 VDC, max. 300 mA in total across both channels |
Digital inputs | |
|---|---|
Nominal input voltage | 24 VDC (-15 %/+20 %) |
Input filter | 10 µs |
Signal voltage "0" | -3 … +2 V |
Signal voltage "1" | +3.7 … +28 V |
Input current | typically 5 mA |
Brake | |
|---|---|
Output voltage | 24 VDC from the power contacts |
Output current | 0.5 A |